Santoprene™ 101-64
Thermoplastic Vulcanizate
 Product Description                                                   Key Features
  A soft, black, versatile thermoplastic vulcanizate (TPV) in the       • UL listed: file #QMFZ2.E80017, Plastics - Component; file
  thermoplastic elastomer (TPE) family. This material combines good        #QMFZ8.E80017, Plastics Certified For Canada - Component.
  physical properties and chemical resistance for use in a wide range   • Recommended for applications requiring excellent flex fatigue
  of applications. This grade of Santoprene TPV is shear-dependent         resistance.
  and can be processed on conventional thermoplastics equipment for     • Excellent ozone resistance.
  injection molding, extrusion or blow molding. It is polyolefin based
  and recyclable within the manufacturing stream.
 General
   Availability 1                           •   Africa & Middle East                • Europe                              • North America
                                            •   Asia Pacific                        • Latin America
   Applications                             •   Automotive - Air Induction System Ducts
                                            •   Automotive - Boots and Bellows for Steering and Suspension
                                            •   Automotive - Plugs, Bumpers, Grommets, Clips
                                            •   Automotive - Seals and Gaskets
                                            •   Automotive - Weather Seals
                                            •   Consumer - Electronics
                                            •   Consumer - Floor Care
                                            •   Industrial - Seals and Gaskets
                                            •   Tubing
   Uses                                     •   Appliance Components                •   Diaphragms                        • Seals
                                            •   Automotive Applications             •   Electrical Parts                  • Tubing
                                            •   Automotive Under the Hood           •   Gaskets
                                            •   Consumer Applications               •   Outdoor Applications
   Agency Ratings                           •   UL QMFZ2                            •   UL QMFZ8
   RoHS Compliance                          •   RoHS Compliant
   Automotive Specifications                •   CHRYSLER MS-AR-100 BGN              • FORD WSD-M2D379-A1                  • GM GMW15813 Type 5
   UL File Number                           •   E80017
   Color                                    •   Black
   Form(s)                                  •   Pellets
   Processing Method                        •   Blow Molding                        • Extrusion Blow Molding              • Multi Injection Molding
                                            •   Coextrusion                         • Injection Blow Molding              • Profile Extrusion
                                            •   Extrusion                           • Injection Molding                   • Sheet Extrusion
   Revision Date                            •   04/01/2017
 Physical                                                 Typical Value (English)                    Typical Value (SI)                 Test Based On
  Density / Specific Gravity                                      0.970                                      0.970                      ASTM D792
  Density                                                         0.970 g/cm³                                0.970 g/cm³                ISO 1183
  Outdoor Suitability                                                f1                                         f1                      UL 746C
  Detergent Resistance                                               f3                                         f3                      UL 749
  Detergent Resistance                                               f4                                         f4                      UL 2157
 Hardness                                                 Typical Value (English)                    Typical Value (SI)                 Test Based On
  Shore Hardness                                                                                                                        ISO 868
    Shore A, 15 sec, 73°F (23°C)                                    70                                         70
Effective Date: 04/01/2017                                                                       ExxonMobil                                           Page: 1 of 4
Product Datasheet
Santoprene™ 101-64
Thermoplastic Vulcanizate
 Elastomers                                  Typical Value (English)         Typical Value (SI)         Test Based On
   Tensile Stress at 100% - Across Flow               410 psi                         2.83 MPa          ASTM D412
   (73°F (23°C))
   Tensile Stress at 100% - Across Flow               410 psi                            2.83 MPa       ISO 37
   (73°F (23°C))
   Tensile Strength at Break - Across Flow            938 psi                            6.47 MPa       ASTM D412
   (73°F (23°C))
   Tensile Stress at Break - Across Flow              938 psi                            6.47 MPa       ISO 37
   (73°F (23°C))
   Elongation at Break - Across Flow                  450 %                              450 %          ASTM D412
   (73°F (23°C))
   Tensile Strain at Break - Across Flow              450 %                              450 %          ISO 37
   (73°F (23°C))
   Tear Strength - Across Flow                                                                          ISO 34-1
     73°F (23°C), Method Ba, Angle                    131 lbf/in                         22.9 kN/m
     (Unnicked)
   Compression Set                                                                                      ASTM D395B
     158°F (70°C), 22 hr, Type 1                       25 %                               25 %
     257°F (125°C), 70 hr, Type 1                      44 %                               44 %
   Compression Set                                                                                      ISO 815
     158°F (70°C), 22 hr, Type A                       25 %                               25 %
     257°F (125°C), 70 hr, Type A                      44 %                               44 %
 Thermal                                     Typical Value   (English)       Typical Value      (SI)    Test Based On
  Brittleness Temperature                              -76   °F                        -60      °C      ASTM D746
  Brittleness Temperature                              -76   °F                        -60      °C      ISO 812
  RTI Elec                                            194    °F                       90.0      °C      UL 746
  RTI Str                                                                                               UL 746
    0.04 in (1.0 mm)                                  194 °F                             90.0 °C
    0.06 in (1.5 mm)                                  194 °F                             90.0 °C
    0.12 in (3.0 mm)                                  203 °F                             95.0 °C
 Electrical                                  Typical Value (English)         Typical Value (SI)         Test Based On
   Volume Resistivity                                                                                   ASTM D257
     73°F (23°C), 0.0787 in (2.00 mm)            1.0E+16 ohms·cm                      1.0E+16 ohms·cm
     73°F (23°C), 0.126 in (3.20 mm)             5.0E+15 ohms·cm                      5.0E+15 ohms·cm
   Dielectric Strength                                                                                  ASTM D149
     73°F (23°C), 0.0787 in (2.00 mm)                 680 V/mil                           27 kV/mm
   Dielectric Constant                                                                                  ASTM D150
     73°F (23°C), 0.0780 in (1.98 mm)                2.50                                2.50
   Dielectric Constant                                                                                  IEC 60250
     73°F (23°C), 0.0780 in (1.98 mm)                2.50                               2.50
   Comparative Tracking Index (CTI)                 PLC 0                              PLC 0            UL 746
   High Amp Arc Ignition (HAI)                      PLC 0                              PLC 0            UL 746
   High Voltage Arc Resistance to Ignition          PLC 6                              PLC 6            UL 746
   (HVAR)
   High Voltage Arc Tracking Rate (HVTR)            PLC 1                              PLC 1            UL 746
   Hot-wire Ignition (HWI)                          PLC 2                              PLC 2            UL 746
Effective Date: 04/01/2017                                               ExxonMobil                                 Page: 2 of 4
Product Datasheet
Santoprene™ 101-64
Thermoplastic Vulcanizate
 Injection                                            Typical Value    (English)             Typical Value    (SI)
   Drying Temperature                                           180    °F                               82    °C
   Drying Time                                                   3.0   hr                               3.0   hr
   Suggested Max Moisture                                     0.080    %                             0.080    %
   Suggested Max Regrind                                         20    %                                20    %
   Rear Temperature                                             350    °F                              177    °C
   Middle Temperature                                           360    °F                              182    °C
   Front Temperature                                            360    °F                              182    °C
   Nozzle Temperature                                   370 to 430     °F                      188 to 221     °C
   Processing (Melt) Temp                               380 to 450     °F                      193 to 232     °C
   Mold Temperature                                       50 to 125    °F                         10 to 52    °C
   Injection Rate                                               Fast                                   Fast
   Back Pressure                                        50.0 to 100    psi                 0.345 to 0.689     MPa
   Screw Speed                                          100 to 200     rpm                     100 to 200     rpm
   Clamp Tonnage                                          3.0 to 5.0   tons/in²                   41 to 69    MPa
   Cushion                                          0.125 to 0.250     in                     3.18 to 6.35    mm
   Screw L/D Ratio                                       16.0:1.0 to                           16.0:1.0 to
                                                           20.0:1.0                               20.0:1.0
   Screw Compression Ratio                        2.0:1.0 to 2.5:1.0                     2.0:1.0 to 2.5:1.0
   Vent Depth                                                1.0E-3    in                            0.025    mm
 Injection Notes
   Santoprene™ TPV is incompatible with acetal and PVC. For more information regarding processing and mold design, please consult our Injection
   Molding Guide.
 Extrusion                                            Typical Value    (English)              Typical Value   (SI)
  Drying Temperature                                           180     °F                                82   °C
  Drying Time                                                   3.0    hr                               3.0   hr
  Melt Temperature                                             385     °F                              196    °C
  Die Temperature                                              390     °F                              199    °C
  Back Pressure                                        725 to 2900     psi                     5.00 to 20.0   MPa
 Extrusion Notes
  Santoprene™ TPV is incompatible with acetal and PVC. For more information regarding processing and die design, please consult our Extrusion
  Molding Guide.
 Aging                                                Typical Value (English)                 Typical Value (SI)              Test Based On
  Change in Tensile Strength in Air                                                                                           ASTM D573
     302°F (150°C), 168 hr                                     -9.4 %                                  -9.4 %
  Change in Tensile Strength in Air                                                                                           ISO 188
     302°F (150°C), 168 hr                                     -9.4 %                                  -9.4 %
  Change in Ultimate Elongation in Air                                                                                        ASTM D573
     302°F (150°C), 168 hr                                     -7.7 %                                  -7.7 %
  Change in Tensile Strain at Break in Air                                                                                    ISO 188
     302°F (150°C), 168 hr                                     -7.7 %                                  -7.7 %
  Change in Durometer Hardness in Air                                                                                         ASTM D573
     Shore A, 302°F (150°C), 168 hr                             1.3                                    1.3
  Change in Shore Hardness in Air                                                                                             ISO 188
     Shore A, 302°F (150°C), 168 hr                             1.3                                    1.3
  Continuous Upper Temperature Resistance                                                                                     SAE J2236
     1008 hr                                                   275 °F                                  135 °C
 Flammability                                         Typical Value (English)                 Typical Value (SI)              Test Based On
   Flame Rating                                                                                                               UL 94
      0.04 in (1.0 mm)                                          HB                                     HB
      0.06 in (1.5 mm)                                          HB                                     HB
      0.12 in (3.0 mm)                                          HB                                     HB
Effective Date: 04/01/2017                                                                ExxonMobil                                      Page: 3 of 4
Product Datasheet
Santoprene™ 101-64
Thermoplastic Vulcanizate
 Additional Information
  Where applicable, test results based on fan gated, 2.0 mm injection molded plaques. Tensile strength, elongation and tensile stress are measured
  across the flow direction. All ASTM and ISO methods shown may be modified by the ExxonMobil laboratory. Test methods are available upon
  request. Compression set at 25% deflection. All products purchased directly from an ExxonMobil affiliate in Europe are REACH compliant. For
  products not imported into Europe by ExxonMobil, customers should assess their legal responsibilities under REACH.
 Legal Statement
  For detailed Product Stewardship information, please contact Customer Service.
   This product, including the product name, shall not be used or tested in any medical application without the prior written acknowledgement of
   ExxonMobil Chemical as to the intended use. For detailed Product Stewardship information, please contact Customer Service.
 Processing Statement
  Desiccant drying for 3 hours at 80°C (180°F) is recommended. Santoprene™ TPV has a wide temperature processing window from 175 to 230°C
  (350 to 450°F) and is incompatible with acetal and PVC. For more information, please consult our Safety Data Sheet, Injection Molding Guide and
  Extrusion Guide.
 Notes
   Typical properties: these are not to be construed as specifications.
   1Product may not be available in one or more countries in the identified Availability regions. Please contact your Sales Representative for complete
   Country Availability.
 For additional technical, sales and order assistance: www.exxonmobilchemical.com/ContactUs
©2020 ExxonMobil. ExxonMobil, the ExxonMobil logo, the interlocking “X” device and other product or service names used herein are trademarks of
ExxonMobil, unless indicated otherwise. This document may not be distributed, displayed, copied or altered without ExxonMobil's prior written
authorization. To the extent ExxonMobil authorizes distributing, displaying and/or copying of this document, the user may do so only if the document
is unaltered and complete, including all of its headers, footers, disclaimers and other information. You may not copy this document to or reproduce it
in whole or in part on a website. ExxonMobil does not guarantee the typical (or other) values. Any data included herein is based upon analysis of
representative samples and not the actual product shipped. The information in this document relates only to the named product or materials when
not in combination with any other product or materials. We based the information on data believed to be reliable on the date compiled, but we do not
represent, warrant, or otherwise guarantee, expressly or impliedly, the merchantability, fitness for a particular purpose, freedom from patent
infringement, suitability, accuracy, reliability, or completeness of this information or the products, materials or processes described. The user is solely
responsible for all determinations regarding any use of material or product and any process in its territories of interest. We expressly disclaim liability
for any loss, damage or injury directly or indirectly suffered or incurred as a result of or related to anyone using or relying on any of the information in
this document. This document is not an endorsement of any non-ExxonMobil product or process, and we expressly disclaim any contrary implication.
The terms “we,” “our,” "ExxonMobil Chemical" and "ExxonMobil" are each used for convenience, and may include any one or more of ExxonMobil
Chemical Company, Exxon Mobil Corporation, or any affiliate either directly or indirectly stewarded.
exxonmobilchemical.com
Effective Date: 04/01/2017                                                                      ExxonMobil                                          Page: 4 of 4