Myhome - Up: For Installation and Catalogue
Myhome - Up: For Installation and Catalogue
BTicino SpA
Viale Borri, 231
21100 Varese - Italy
www.bticino.com
Music
Coloured light
Light
Rolling shutter
                                                                                                                                                                                                                        GUIDE
                                                                                                                                                                                                             FOR INSTALLATION
                                                                                                                                                VOICE
                                                                                                                                              COMMAND
                                                                                                                                                        CONTROL WITH
                                                                                                                                                        SMARTPHONE
                                                                                                                                                                       MANUAL
                                                                                                                                                                       CONTROL
                                                                                                                                                                                  TOUCH
                                                                                                                                                                                 CONTROL
                                                                                                                                                                                                               AND CATALOGUE
MyHOME_Up
            HOME AUTOMATION
               EVOLUTION
INTRODUCTION – PROJECT GUIDELINES
ENERGY MANAGEMENT
- Temperature control
- Load control and consumption display
SYSTEM INTEGRATION
                                               Contents   MyHOME_Up
CONTENTS
           INTRODUCTION
           General features. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
           PROJECT GUIDELINES
           General features. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 22
             Functional diagram of a MyHOME_Up system. .  .  .  .  .  .  .  .  .  .  .  .  .  .22
           Preliminary project and system layout. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 24
             The installation of a BUS system . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .24
             Light and automation system. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .28
             Temperature control system .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 29
             Consumption display and load control system. .  .  .  .  .  .  .  .  .  .  .  .  .  .32
             Burglar-alarm system. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .34
             NUVO Multiroom audio system . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .35
             Selection and positioning of the electric panel. .  .  .  .  .  .  .  .  .  .  .  .  .  .36
             Positioning of the junction boxes . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .44
                                                                                                                 Contents   MyHOME_Up
LIGHTS AND AUTOMATION
General features. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 46
  Light and shutter automation system .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 46
Wiring diagrams . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 64
  Diagram 1 - Switching on and off of 2 lamps with 4 light points
  with general ON/OFF control . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .64
  Diagram 2 - Automatic switching on of the light with passive
  infrared ceiling sensor. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .64
  Diagram 3 - Alternate current motor control for shutters, curtains,
  or motorised shutters . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .65
  Diagram 4 - Switching on and off of one lamp and shutter control
  using an actuator control . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .65
  Diagram 5 - Switching on, off and adjustment of the light level
  of fluorescent lamps through “ballast”. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .66
  Diagram 6 - Switching on, off and adjustment of the light level
  of LED lamps. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .66
  Diagram 7 - Lighting system with presence and
  lighting sensors - large meeting room. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .67
  Diagram 8 - Lighting system with presence and
  lighting sensors - hall and reception. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .68
CATALOGUES
  MyHOME_Up catalogue . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 108
  MyHOME_Up FLATWALL catalogue .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 130
  Appendix.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 142
                                                                                                                Contents   MyHOME_Up
    GENERAL FEATURES
Music
Coloured light
Light
Rolling shutter
MyHOME_Up App
                                                MyHOME_Up
                                                system
BUS
Digital controls
2
CONTROL MyHOME_UP AS YOU WISH
All the functions may be managed:
- with voice commands using the Google Home
  and Amazon Alexa voice assistants.
- using the Smartphone and dedicated app;                 VOICE COMMAND   CONTROL WITH
                                                                          SMARTPHONE
                                                                                              MANUAL
                                                                                              CONTROL
                                                                                                           TOUCH
                                                                                                          CONTROL
- with flush-mounted manual controls;
- with HOMETOUCH Touch Screen devices.
LAN network
                                                                       Air conditioning
                                                                       systems
MyHOMEServer1
                                                                       Management of
                                                                       weather stations
                                                                       and sensors
                                                                                          Introduction   MyHOME_Up 3
   WWW.BTICINO.COM
    GENERAL FEATURES
     System which can manage up to 175 channels (*)                                                                             In particular it is possible to associate the
     (lamps, shutters, controlled sockets etc.).                                                                                devices found in the system and create
     MyHOME_Up application allows start up of the                                                                               single and general commands and groups
     light and automation system and the check of the                                                                           of lights and shutters.
     operation of the individual devices.
                                 Basic contact
                                 interface                                         Shutter control                                                                             Light control and Full controls
          Traditional
          device
Power supply
230 Va.c.
                                                                                                                              TV/SAT                IPTV
                                                             DIN                                                                                                               DIN
                                                             module                                                                                                            module
                                                             actuator                                                                                                          dimmer
                                                                                                                                                                               actuator
                                            automazione   diffusione sonora   antifurto   termoregolazione   videocitofonia    controllo   lan   controllo carichi   energia        luci    tvcc    www   irrigazione
Shutters Lights
     Note (*): Channel means the individual relay or output of the actuator for the management of the load.
     The count includes any preset or unused outputs.
     For example, actuator F411/4 with 4 independent relays is identified in the MyHOME_Up as a 4-channel device.
4
Manageable functions
  	different lights and loads with ON/OFF and dimmed control;
  	rolling shutters with UP/DOWN control and management of the preferred position;
  	automatic switching on of loads as a function of presence (using sensors) or the closing of a
   contact (using contact interfaces).
                                                                   Basic
                                                                   actuator
MyHOMEServer1
                                                                                                       Internet
                                                          Lights
                                                                                        Introduction   MyHOME_Up 5
      WWW.BTICINO.COM
    GENERAL FEATURES
                                              Zone 1                      Zone 2
     Power supply                             sensor                      sensor
MyHOMEServer1
                                                                                                      Internet
                                                                                Cold
                                       M
                                      0÷10V
                                                                                Hot
6
                LOAD CONTROL SYSTEM
Electricity meter
                                                                     HOMETOUCH
                    Electrical switchboard
BUS SCS
230 Va.c.
230 Va.c.
                                                                                                  Introduction      MyHOME_Up 7
      WWW.BTICINO.COM
    GENERAL FEATURES
    System for display by means of energy meters                 In the MyHOME_Up App the installer must enter the
    (max. 128) of consumptions of electricity and                addresses of compatible devices, such as the electricity
    the production of instantaneous electrical                   meter, item F520, and the load control unit, item F521
                                                                 (consumption display only).
    energy.
    Manageable functions
     	the instant electrical consumption/production value
      can be displayed by the MyHOME_Up APP.                                  Photovoltaic
                                                                              panel
     	the App can use the consumption value as a condition
      for activating Smart scenarios.
       Compact
       power supply
                                                                       Electric              Energy
                                                                        power                  Data
                                                                        meter                Logger
                                                Energy Display
                                                                                                      MyHOMEServer1
                            Central unit for
                            load management
Internet
8
                WIRE-RADIO BURGLAR-ALARM system
KEYPAD
Internet
                                                                                                      Expansion
                                                                                                      modules
Modem                     Network cable                             4-conductor cable     BUS
router
MyHOMEServer1
Central unit
Multipolar cable
Volumetric sensors
                                  Volumetric sensors
          Light and
      automation system
Siren
                                                                                        Introduction       MyHOME_Up 9
    WWW.BTICINO.COM
     GENERAL FEATURES
                                                                                Player
     Manageable functions
      	player on/off and volume adjustment;
      	source selection (streaming radio, local network or
       Smartphone mp3 files, etc.);
      	creation of scenarios with activation of players in the
       various zones of the home.
     Moreover, if the system is managed using “scenario”
     type commands, it will be possible to also manage the
     functions using Amazon Alexa and Google Home voice
     commands.
                                                                                         Internet
                                                                 Modem router
10
                       BATHROOM                       BEDROOM
                                  Speaker
Speaker
Player Player
                                                 LIVING ROOM
                                  Speaker
Player
                                                Introduction   MyHOME_Up 11
WWW.BTICINO.COM
     GENERAL FEATURES
     MyHOME_Up may be controlled using your voice, flush mounted controls, customised digital controls,
     the HOMETOUCH 7” touch screen, or the smartphone App, which also allows remote control of the
     home.
VOICE ASSISTANT
                                                           Living Now digital control with integrated Amazon Alexa voice assistant
12
CONTROL WITH MANUAL CONTROLS
Living Now digital controls
Available in the “all key” Living Now range and
with capacitive pushbuttons, these devices
have LED icons that can be selected using the
MyHOME_Up App based on the function to
manage.
Two versions for each need:
- LIGHT control to manage the lighting (1 or 2
  lights, groups and general control);
- FULL control to manage from 1 to 3 light,
  dimmer, shutter, NUVO audio, load control,
  scenario and coloured light functions.
                                                             Introduction      MyHOME_Up 13
    WWW.BTICINO.COM
     GENERAL FEATURES
Rolling shutter
Luce
                                                                  Luce colorata
14
                                                                  Musica
                                                                   Temperature control
                                                                   status notification
CONTROL WITH HOMETOUCH
                                                                               Automation and audio
TOUCH SCREEN                                                                   status notification
Thanks to the simple and immediate
interface, with this touch device -
item 3488 (black) and item 3488W
(white) -, users will have all the
functions of the MyHOME_Up
system at their fingertips:
- 	Lighting;
- 	Shutter automation;
- 	Temperature control;
- 	Nuvo multi-room sound system;
- 	Scenarios;
- 	Function possible thanks to the
   integration of third-party devices
   and systems.
In addition, HOMETOUCH also
integrates the BTicino video door
entry system and can be used as
connected internal unit for the
handling of calls both locally and
from the Smartphone, using the free
DOOR ENTRY App for HOMETOUCH.
BUS
                                                                                         Wi-Fi Modem
                                                                                         router
MyHOMEServer1
                                                                         Introduction      MyHOME_Up 15
      WWW.BTICINO.COM
     GENERAL FEATURES
     The putting into operation of the system and the definition of the functions with the command-
     actuator association is easily completed using the MyHOME_Up App and the MyHOMEServer1
     gateway connected to the BUS and the Internet network.
     During system operation, the gateway allows users, both inside and outside the home, to manage the
     functions and customise their scenarios using their own Smartphone and the MyHOME_Up App.
     The putting into operation of the system only requires a few steps:
1                                                         3
            Connect all the devices and the                     Start the App which
            MyHOMEServer1 device to the BUS system.             will connect to the
            The self-learning procedure will be                 system using Access
            completely automatic. After a few minutes           Point.
            all the actuators will be working perfectly
            with default modes.
MyHOMEServer1
2                                                         4
            Install MyHOME_Up which can be                      After logging in select the room of the home and the
            downloaded free from Android and iOS                function to be defined.
            stores, on your smartphone or tablet.
Ground... Kitchen
Add an object
                                                                   Player       Smart TV
                                                                                           3   Controlled
                                                                                                socket
16
     5
                   Press the pushbuttons of the
                   devices which perform the function;
                   if it is difficult for you to reach
                   the devices you can easily select
                   them from the list of those which
                   MyHOME_Up has found on your
                   system.
PUSHBUTTON
     6
                   Associate all the control devices by pressing their pushbuttons. At the end of the association all
                   the controls selected will be working perfectly. You will also have created the graphic object to
                   check the function from the mobile device.
                               Identified device
63
                                      MOD: H4652/2
                                      ID: 00B475CE
                                 No start condition
                                  for this scenario
                     Choose the pushbutton to be associated
1 2 PUSHBUTTON
     WARNING: the list of energy Management and Automation devices that can be associated using the MyHOME_Up App is available in the Appendix
     pages at the end of the Guide. Any other unlisted devices can be configured using the MyHOME_Suite software discussed in the “Software and
     Services” chapter
                                                                                                          Introduction        MyHOME_Up 17
          WWW.BTICINO.COM
     GENERAL FEATURES
An open system
Music
Coloured light
Actuators Light
Rolling shutter
                                                                                                                        MyHOME_Up
                                                                                                                        APP
                                                           MyHOME_Up
                                                           system
     BUS                                                                                                    LAN network
MyHOMEServer1
                                                                                            Lighting with
                                                                                              RGB lamps
DMX
18
2. INTEGRATION WITH DRIVER MANAGER ITEM F459:
- 	Specific device for the use of integration drivers purposely created based on the characteristics and functions of
   the system to integrate (for example to integrate MyHOME_Up with HVAC Samsung and Mitsubishi systems, etc.);
- scalable and customisable solution for the realisation of functions not available with the MyHOME_Up system;
Reliable operation thanks to local interoperability.
SPECIFIC DRIVER
                                                                                  Air conditioning
                                                                      LAN         systems
                                         BUS                          network
                                                                                  Sensors,
MyHOME_Up                                       Driver manager F459               measurement
                                                                                  devices etc.
                                                                                          Introduction   MyHOME_Up 19
     WWW.BTICINO.COM
     GENERAL FEATURES
MyHOME_Up App
                                                                                                              Scenario activation
                                                                                                                     pushbutton
20
CONTENTS
                 MyHOME_Up – Project guidelines
                 General features. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 22
                 Preliminary project and
                 system layout. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 24
     The procedure for the creation of a MyHOME_Up system                         It will be necessary to install a wired and Wi-Fi network
     is similar to that for a traditional system.                                 connected to the Internet, for the integration of
     Power supplies and other DIN modular devices must be                         MyHOME_Up with the burglar-alarm system, with the
     installed in a general panel. All the others must be flush                   NUVO audio system, and with any installed third-party
     or wall mounted.                                                             devices.
     However, differently from traditional wiring, in this case                   Internet connection is also required for the remote
     the wiring will be using a grey 2 wires BUS cable for                        control of the system using a Smartphone.
     MyHOME_Up devices, and a white one for video door
     entry devices.
                                            MyHOME_Up
                                            APP
         Music
Coloured light
Light
Rolling shutter
                                    ADSL line
                                    (Intenet)
                          ELECTRIC PANEL
                                                                                                      Video door entry system BUS
LIGHT/SHUTTER AUTOMATION
MyHOMEServer1
MyHOME_Up BUS
22
  The MyHOMEServer1 device is at the heart of all the            As it can easily be seen in the diagram, some
  integrated system. When putting the system into operation,     MyHOME_Up system components are integrated with
  it is used to recognise and associate to each other all the    each other by sharing the BUS cable, while others,
  installed devices. It also acts as a gateway, allowing the     such as the Burglar Alarm system and the NUVO
  user to control the functions of the system and of third-      audio system, third-party products (for example
  party products using the HOMETOUCH touch screen,               coloured lamps) and voice assistants, are integrated
  Amazon Alexa or Google Home voice commands, or                 with the system through the wired or wireless
  remotely using the Smartphone and the MyHOME_Up App.           domestic LAN network connection.
LAN network
NUVO Player
optional connection
                                VIDEO DOOR ENTRY SYSTEM
HOME TOUCH
     The MyHOME_Up home-automation system uses BUS                  As can be seen from the diagram given below, relating
     installation technology: all the devices are connected         to the lighting system, the power line for the load power
     “in parallel” by means of a two-conductor wire, used           supply is free of the control line and the control line is
     to transport the information and low-voltage electrical        independent of the functional wiring.
     power supply (27 V d.c.).
     L
     T
     N                 Actuators in switchboard
BUS
24
MAKING THE WIRING
26
The following table can help to select the type of cable to use based on the MyHome application.
                                                                        MYHOME APPLICATIONS
                                                          COMFORT                          SAVING          COMMUNICATION        CONTROL
                     BTicino
                     336904
                     and 336905             (*)             (*)               (*)            (*)
                     L4669HT
                     (white)
                     BTicino
                     L4669 and
                     L4669/500
                     (grey)
                     BTicino
                     L4668CM
                     UTP 5
                     Multi-pair
                     UTP 5E
                     BTicino
                     C9881U/5E
                     C9882U/5E
Cables that may be used (for every system check against the installation regulations)
NOTE (*): Mandatory for the underground sections of the individual systems
        actuators.
     - 	more than 3 rooms: group
        together and, when convenient,
        distribute the actuators inside
        junction boxes. A “flush mounted”
        actuator should be preferred for                                                                                    BUS
        the shutters.
     - 	several floors: install an electric
        panel for each floor, for grouping
                                                                                Control device                  Control device
        the actuators together. Where it is
        convenient to install the actuators
        in junction boxes.
                                                                                                                   Junction box
                                                                                 BUS
Power supplies
     L
     T
     N
                                                                                                                                 Actuator
                         Temperature Control
                         Probe
                                            Control device                                                    Control
                                                                                                              device
BUS
Distributed installation: actuators and control devices are installed in device or junction boxes.
28
Temperature control system
The design of a temperature control system must be completed with the help of the temperature control
system/water system designer, in order to allow for the following requirements:
                                                       M
- 	with open/close contacts
	
            M
                                               cannot be directly managed
                                               by the MyHOME temperature
- 	with open/close contacts                    control system. They require
	 0÷10 Volt                                    an external control unit
                                               supplied by the radiant panel
                                               system manufacturer.
            M
          0 to 10
                                                                                 Project guidelines          MyHOME_Up 29
     WWW.BTICINO.COM
     PRELIMINARY PROJECT AND SYSTEM LAYOUT
                                                               Kitchen
     NOTE:                                                                                          Bathroom      Bedroom
                                                                                                    Bathroom
                                                                 Kitchen
                                                                                                                  Bedroom
            Distribution
            manifold
                                                                Etrance
                                                                hall
            Zone solenoid
            valves                                                                                       Living room
Counter
30
DISPOSITION OF SOLENOID VALVES AND ACTUATORS
                                                                 C1 C2
                                                                           4
                                                                               ART.F430/2
                                                                                            1 2 3 4
                                                                                            1   2 3
                                                                                            C1 C2
                                                                                                      4
                                                                                                          ART.F430/2
                                                                                                                       1 2 3 4
                                                                                                                       1   2 3
                                                                                                                       C1 C2
                                                                                                                                 4
                                                                                                                                     ART.F430/2
                                                                                                                                                  1 2 3 4
                                                                                                                                                  1   2 3
                                                                                                                                                  C1 C2
                                                                                                                                                            4
ART.F430/2
Box
Fan-coil systems                         Installation of the solenoid valve                                                                                                          Installation of the solenoid valve
                                         in 2-tube fan-coils                                                                                                                         in 4-tube fan-coils
In fan-coil systems the solenoid
valve may be installed inside the fan-
coil itself. In 2-tube systems there
is one single solenoid valve for both
the heating and cooling function. In
4-tube systems there are 2 solenoid                                                                                                                             M                                                      M
valves, one for heating and one for
cooling.
     TYPE OF WIRING
     The selection of the way the load is managed (forced reactivation in case
     of disconnection) and the mode for the display of the energy consumption
     levels define the characteristics of the electric wiring.
              Power cables
              BUS cable
Power cables
              BUS cable
                                                           Load control panel
32
CONSUMED AND PRODUCED ENERGY DISPLAY
Group the DIN module meters in the switchboard. Install energy meters, with their toroids, for each electric
line for which the display of consumption is required.
Switchboard
                                                                   Photovoltaic
                                                                   panel
BUS
Inverters
LAN network
                                                                                  Electric
                                                                                  power                 Energy Data
                                                                                  meter                 Logger
Burglar-alarm system
     TYPE OF WIRING
     The installation of a burglar-alarm system is completed with 3 different types of wiring.
     a) BUS wiring with 4-conductor cable for the parallel                       b) “star” wiring with 4-conductor cable for connection
        connection of the following devices:                                        to the control unit of all the sensors (volumetric
     	- keypad;                                                                     sensors, magnetic contacts, etc.).
     	- expansion modules;                                                       b) Control units with Ethernet port must be connected
     	- telephone communicators;                                                    to the Internet through the home LAN network using
     	- sirens.                                                                     appropriate wiring.
                                                                                 For further details see the “New Burglar-Alarm System ”
                                                                                 technical guide.
                                                                    Volumetric
                                                                    sensor
             Volumetric                                                                                   Magnetic contact
             sensor
Star wiring
                                                                                                                       Volumetric
         Volumetric sensor                                                                                             sensor
Keypad
                                                +   A   B   -
                                                                System central
                                                                unit                                                         External siren
                                                                   Cable shield-
                                                                   ing
34
                                                +   A   B   -
NUVO multiroom audio system
TYPE OF WIRING
IT is possible to create three different types of system:         - WIRELESS SOLUTION: in this case all the players with
- WIRED SOLUTION: all the players are connected to the              their speakers can be distributed freely in the various
  LAN network using a network cable belonging to cat.               rooms.
  5E or higher.                                                   - MIXED SOLUTION (wired LAN with radio expansion): if
The devices can be installed:                                       sound systems are to be set up in rooms which do not
- in an appropriate rack;                                           have wired LAN network a mixed wired-radio system
- in every room (stand-alone installation).                         can be created.
In the first case the wiring of all the speakers is from          For further details see the “NUVO Multi-Room Audio
the rack.                                                         System” technical guide.
When designing the NUVO multi-room audio system, it must be considered that this requires connection to a LAN
network with Wi-Fi modem/router, in order to take advantage of shared streaming music services and for any
firmware updates for the management of products and Apps.
Tabletop
                                                                                                              1-zone player
                             KITCHEN
LIVING ROOM
Soundbar
    Rack
                                                     LAN
a maximum total of 5
STUDIO
                                                           Modem/
                                                           Router
                                                           Wi-Fi
                                                                                                                1-zone player
                      Tabletop
                                              LAN                                                  LAN
                                                                                     to other zone
                                                                                     players or LAN
                                                                                     network devices
                                                                                    MyHOME
                                                                                    FLATWALL 150
36
ELECTRIC PANEL POSITION
The position of the electric panel must be defined based on the type of building. It is recommended to agree
with the installer the most appropriate position of the electric panel (if not already decided).
                                                                                                                                                                038 42                                         device
Electric                             mounted                                                                                       C1              C2
panel devices
                                                                                                 1       2            3      4
                                                                                             1       2   3        4
038 42
                                                                                             C1              C2
                                                                                                                                                                                                                     Flush
                                                                                                                                                                                                                     mounted
                                                                                                                                                                                                                     devices
                                                                             Electric
Multi-floor building                                                         panel                                                                                       1
                                                                                                                                                                             1
                                                                                                                                                                                 2
                                                                                                                                                                                     2
                                                                                                                                                                                     3        4
                                                                                                                                                                                                  3      4
C1 C2
stairs, and a panel for each floor in a central position.                                                                                                                                                               3rd FLOOR
DIN devices will partly be centralised and partly
distributed.
2nd FLOOR
1st FLOOR
                                                                 Technical
                                                                 room
                                                                                                                                                                             1       2            3      4
                                                                                                                                                                         1       2   3        4
038 42
C1 C2
                                                                                                                                                                                                                      Flush
                                                                                                                                                                                                                      mounted
                                                                                                                                                                                                                      devices
                                                              MyHOME
                                                              FLATWALL 150
38
The Flatwall offer includes a box intended for
the installation of multimedia devices (router,
modem, etc.) part of the Home network,
which is approved by all the main telephone
operators.
                                                                          2
                                                                                   1
      Electric panel type solution
40
                                                                               MyHOME FLATWALL 240 - 270
                                                                               Switchboard solution
         FLOOR RISER
  3      Configuration going through the various floors of the
         building, for wired distribution of common services
         (only possible with Flatwall 240-270).
                                                2
                                                                  3
     The compact sizes of the flush                   If installed during the construction               then installed on the metal base
     mounting bases, only 8.5 cm                      of the wall, the metal base also                   already in the wall.
     thick, make it possible to install               allows construction material                       To preserve their integrity, the
     MyHOME FLATWALL using the                        savings.                                           finishing elements can be installed
     same procedure as for pocket                     The required device holders can be                 after completing the masonry
     sliding doors.                                   equipped before being installed, and               works.
         NOTS: for installation in bearing walls, make a 60 cm wide recess from floor to ceiling. For partition or plasterboard walls, leave an
         opening of approximately 60 cm during the construction of the wall.
42
Example of typical masonry wall
installation.
The position and the quantity of junction boxes must be assessed based on the type of building.
30 cm
                                                NOTE: For the installation of the boxes refer to the IEC 64-50 standard.
                                                The guide recommends a height from the floor exceeding 17.5 cm.
                                                We recommend approximately 30 cm.
44
CONTENTS
                 MyHOME_Up – Lights and automation
                 General features. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 46
                 Wiring diagrams . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 64
     The system allows to use physical commands, touchscreen devices, smartphones and voice commands to
     manage the following functions:
                             Basic contact
                             interface                       Digital controls                                                                                                     Voice control
             Traditional
             device
Power supply
230 Va.c.
automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci automazione tvcc diffusione sonora www antifurtoirrigazionetermoregolazione videocitofonia controllo
46
SYSTEM COMPOSITION                                         Both devices are available in the
In the system there are two types of                       advanced digital version, with Living
device:                                                    Now finish, or in the version with silk-
                                                           screen printed key covers, and with
-	Controls, connected only to the BUS
                                                           Living Now, Axolute, Livinglight and
wire;
                                                           Matix finish.
- 	Actuators, connected to the BUS
                                                           The range of control devices is
   cable and to the 230 Vac power line
                                                           completed with other capacitive
   to manage the load.
                                                           sensor and IR infrared products.
Music
Coloured light
Light
Rolling shutter
           Basic
           actuator                                                                                                           TV/SAT                IPTV
automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazione
                                                                                                  MyHOMEServer1
                         Full control and
                         shutter actuator
Lights Shutters
Support K470..
                                                             Blanking
                                                             module K4950
                                                                                                                     Function indication
                                                                                                                     LED matrix
                                                                         Electrical
                                                                         contact
                                      
                                           Connection
                                             modules
                                                             2
                                         Electrified frame
48
They are available in two versions:
- FULL controls: advanced devices that can be set using the MyHOME_UP App, with a LED matrix
  for the definition of a wide range of functions, such as ON/OFF and Dimmer lighting, shutter
  management, scenarios, NUVO player, coloured light, load management etc.
	 IT is possible to simultaneously manage up to 3 different functions.
With reference to the illustration of the previous page,                      This solutions simplifies wiring of two or more control
digital devices are installed in their respective flush                       devices as it is no longer necessary to have a “parallel”
mounted box and support, item K470..., using an                               connection of the BUS cable. At the same time, it also
appropriate “frame” with 27 Vd.c. control device power                        facilitates the replacement and repositioning of the
supply contacts.                                                              control device, also by the user, without the need for
The BUS cable is connected to the electrified frame                           wiring.
using the connection module, item K8001.
Removal of the control devices from the electrified frame for installation in a different position.
      Flush mounted
      boxes                                502E                                503E                                                  504E
                                      (70x70x50 mm)                    (108x74x53.5 mm)                                         (133x74x53.5 mm)
      Plasterboard boxes
                                                                              PB503N                                                PB504N
                                          PB502N                                                                                (132.5x71x52 mm)
                                      (ø 71x50.5 mm)                    (110x71x52 mm)
      Supports
                                          K8102                        K4703 with screws                                     K4704 with screws
      Flush mounted
      devices
      - connection module                                     *                                                             *
        K8001;
      - actuators K8002L
        and K8002S;
                                                                  3 modules                                                       4 modules
      - additional power
        supply K8003
       (2 modules).
      Blanking module
      K4950
                                                        max. 2 blanking modules                                          max. 3 blanking modules
      Electrified frame
                                        3 modules            3 modules                3+1 modules               4 modules                     4+1 modules
                                         ..8102P1              ..8103                   ..8103P1                  ..8104                        ..8104P1
50
            ALLOCATION OF THE FUNCTIONS TO
            MANAGE
               Pian... AND   CONFIGURATION OF
                         Cucina                ICONS Cucina
                                            Pian...                                                                               Pian...        MyHOME_Up
                                                                                                                                                   Cucina  App                                   Pian...
           Using the same App, it will be possible to select the symbol                                                                                                                                        Pian
                          Identificazione
           of the function   managed.
                         Attuatore/Uscita                                                                                              Scegli il canale da associare
                                                                                 Attuatori/uscite compatibili                       con Luce Cucina 1 di Piano terra -                                F411/4 - ID:00
                       Per identificare l'attuatore/uscita da                           Luce Cucina 1                                              Cucina                                             Nessuna etich
                     associare al'oggetto grafico Luce Cucina                 Ricerca per ID o modello
                      1, premi uno qualunque dei pulsanti a
                              bordo del dispositivo                                  F411/4 - ID:00D16020
                                                                                                                   Test                                                                               H4652/2 - ID:
                                                                                     Nessuna etichetta
                                                                                                                                                        1         2                                   Pulsante 1
                                                                                     KW8002L- ID:00D1604B                                                                                             Nessuna etich
                                                                                                                   Test
                                                                                     Nessuna etichetta
                    A te la scelta
                            Non posso premere il ...                      Aggiungi un pulsante
                                                                                Aggiungi  dispositivo                              Controlla un altro
                                                                                                                                                 OK oggetto                                                  Pre
                                                                                                                                                                                                           Aggiun
                                                                   Il tuo comando accende una sola luce ma da                  Il tuo comando controlla una luce ma vorresti
     Con Living Link decidi tu cosa è meglio per te.
                                                                     quel comando ne vorresti accendere anche                          gestire un gruppo di tapparelle?                                     Per ini
      Vediamo qualche esempio di cosa    pui fare
                                       Chiudi                                       un'altra? Chiudi                                          Cambia Annulla
                                                                                                                                                      funzione
            Activation
                 Presa TVof the MyHOME_Up system -                       Customisation of the functions by the user
            definition of the LIGHT command for the                      - definition of the FULL command for the
            control
                Bagnoof two lights.                                      control of 2 separate light points.
Lampada piantana
LIVING NOW DIGITAL CONTROL DEVICES WITH AMAZON ALEXA VOICE ASSISTANT
     The “Voice command” device, item KG/KS/KM8013,                for “voice” control of the home automation functions of
     brings together the functions of two digital controls for     MyHOME, and to request any information, news, weather
     the management of lights with cyclical ON/OFF mode,           conditions, timetables, and so on, using the Amazon
     with an integrated voice assistant exploiting the Amazon      Alexa platform.
     Alexa technology.                                             The integration of the voice activated controls with
     The advantage resulting from the use of this device is        the MyHOME_Up system is ensured using the
     clear: the installer can offer to their customer an added     MyHOMEServer1 device.
     value service, setting “by default” each room of the home
                                             Voice control
                                             KG8013
     Voice control power supply                                       Rear clamp for power                         27 Vd.c. power supply
                                                                      supply 110–240 Va.c.                         contacts for connection
     The BUS 27 Vd.c. power supply is supplied to the voice                                                        module or actuators
                                                                                                27 Vd.c. power
     command device by the connection module, item K8001,                                      supply contacts
     through the electrified frame, item 8103/P1, or item                                     for voice control
     8104/P.
     In addition to the above module, it is also possible to use
     the extra flush mounted 2 module power supply, item
     K8003.
     For further details, see the technical sheets of the
     power supply and voice control.
                                                     Blanking module
                                                     K4950
                                                       Electrical
                                                       contact
                          Connection
                   1        modules
Electrified frame
Voice control
                      Blanking
                      module
                                     
                    Connection
                       module
                                               Actuator
                                                                  2
                                              Electrified frame
                                                                                               3
                                                                            Digital controls
                                                                  and/or blanking modules
54
CONTROL DEVICES WITH KEY COVERS
They are completed with two types of keys and key covers:
- With 1 function, one or two modules, to be used with the grey control key;
- With 2 functions, one or two modules, to be used with the black control.
All the devices have luminous indications, which can be adjusted or excluded, for the
notification of the status of the load, and so that they can be seen in the dark.
  Upper pushbutton
                                                    Lower pushbutton
LED
The control with single key cover can be compared         The control with double key cover (rocker) can, on the other hand, can be compared with
with a traditional closing contact (pushbutton or         a traditional exchange contact.
switch).                                                  NOTE: the control keys are supplied with the device.
56
CONTACT INTERFACES
                                                          Contact interface
These devices integrate the traditional control           in DIN module
equipment (switch, pushbutton, etc.) in the MyHOME_       item F428
Up BUS system and allow their use in rooms where
traditional systems are already present or in historic
and prestigious rooms whereby the complete or partial
remaking of the electric system would entail heavy
masonry work.                                                           Contact interface
                                                                        in basic module
                                                                        item 3477
Cyclical ON/OFF
Timed controls
                  Normal UP/DOWN
                  and safe UP/DOWN
     AUTOMATION   mode shutter control
                  General, room, group
                  controls
     SCENARIO
     MANAGEMENT
58
8-Key control         Brightness and movement/   Nighter e Whice capacitive   Contact interface
                      presence sensor            control
H/LN4652
                      HC/HD/HS4658
                      HC/HD/HS4659
                      L/N/NT4658                 HD4657M3/4
                      L/N/NT4659                 HC4657M3/4
                      BMSE3001                   HS4657M3/4
                      BMSE3003
                      048834
                      K4659	                                                  F428          3477
                                                            Upper pushbutton
                                         Lower pushbutton
LED
Control key
Control key
     Key cover
     1 function
     2 modules                                                           Remote              Key cover
                                                                         actuator            2 functions
                                                                         “control”           2 modules
                                                        Light            key cover
                                                        management
                                                        “actuator”
                                                        key cover
60
Basic modularity devices - flush mounted installation
Box
                                                                                          L1
                                                                                               M L2
                                                       L
                                                                                                Pushbutton UP
                                                                     MQ01016-a-IT        27/04/2015
     Actuators with164
                    preset and position
     calibration function
     Devices with 2 interlocked relays for the control
     of standard motors with automatic calibration,
     standard with manual calibration, and pulse motors.
     Available in all the flush mounted civil versions and
     2 DIN module versions, to be used with the specific
     control device.
62
SIZING OF THE SYSTEM                   The length of the cable must also                 - 	For optimum division of the
When sizing the system, check the      be considered, complying with the                    currents on the bus line, it
absorption of the devices to ensure    following rules:                                     is recommended that the
correct system operation. With         - 	The length of the connection                      power supply is installed in an
absorption levels below 600 mA,           between the power supply and                      intermediate position.
it will be possible to use compact        the furthest device must not
power supply E49. With absorption         exceed 250 m.
levels between 600 and 1200 mA,        - 	The total length of the
power supply E46ADCN must be              connections must not exceed
used.                                     500 m (laid out cable).
For the current absorption of the
device see its technical data sheet.                                                                         ON
OFF
                                         B	     = 250 m max                                                                                                B
                                                                                         E46ADCN
                                         A + B 	 = 500 m
NOTE: For the sizing of the lighting system with light and movement/presence sensors,
refer to the technical data sheets of the products available at the bticino.com website
and the homesystems-legrandgroup.com website.
     DIAGRAM 1
     SWITCHING ON AND OFF OF 2 LAMPS WITH 4 LIGHT POINTS WITH GENERAL ON/OFF CONTROL
                            N
                            L
        E46ADCN                       H4672M2          ON
                                                                                                  L1    H4672M2             ON
                                                                                                                                                     L2
OFF OFF
H4652/2 ON H4652/2 ON ON
GEN
     DIAGRAM 2
     AUTOMATIC SWITCHING ON OF THE LIGHT WITH PASSIVE INFRARED CEILING SENSOR
                                              N
                                              L
                          E46ADCN                              3476     L        L1
                                                                                            1 1
                                                                      ART. 3476
                                                                            230V ˜
                                                                            2A cosϕ = 0,6
                                                                            2A
HD4659 H4652/2 ON
                                                                                                                                   For other
                                                                                                                                   functions
                                                                                                                      OFF
     The device controls the load with the address indicated in A and PL. When a presence is detected, if the light level is below the set level the device
     switches on the assigned load and keeps it on for a period of time set using the configurator in T. The sensitivity of the PIR movement sensor is set
     using the configurator in S. For correct operation, it will be necessary to set the sensor lighting setpoint (see procedure).
64
DIAGRAM 3
ALTERNATE CURRENT MOTOR CONTROL FOR SHUTTERS, CURTAINS, OR MOTORISED SHUTTERS
            N
            L                                      N                                N                                                     N
                                                 M1                                M2                                                    M3
                                            L1         L2                     L1          L2                                        L1        L2
E46ADCN
 230 Va.c.
                                                                                   BUS
                                                                                                                                                        To other
                                                                                                                                                        devices
DIAGRAM 4
SWITCHING ON AND OFF OF ONE LAMP AND SHUTTER CONTROL USING AN ACTUATOR
CONTROL
                     N
                     L
                                                                         L1
 E46ADCN                                                                                                 L        L1                               L2
                                                                       M
                                                                                                                              1 1
ART. 3476
                                                                  N                                          230V ˜
                                                                                                             2A cosϕ = 0,6
                                                                                                             2A
L2
                                      H4672M2(*)                                                      3476
230 Va.c.                                                                                                                                                    BUS
                                                                                                                                                         To other
* Complete the device with key covers as per the drawing:                                                                                                 devices
ON
OFF
     DIAGRAM 5
     SWITCHING ON, OFF AND ADJUSTMENT OF THE LIGHT LEVEL OF FLUORESCENT LAMPS
     THROUGH “BALLAST”
                                                                                                                     N
                                  L                                                                                      230 Va.c.
                                                                                                                     L
                                  +
F413N
                  Ballast                                          1 2 NC 3 4
                                                                   -+
                                                                   0-10V
                                                                                ART. F413N
                                            E46ADCN
                 N L - +                                            C1
                                           230 Va.c.
                                                                                             BUS
                                                                                                                     To other
                                                                                                                     devices
OFF
     DIAGRAM 6
     SWITCHING ON, OFF AND ADJUSTMENT OF THE LIGHT LEVEL OF LED LAMPS
                            N
                            L
                                    DIN
                                dimmer
      E46ADCN                   actuator
F418U2
     230 Va.c.
                                                       BUS                                                To other
                                                                                                          devices
ON
66
DIAGRAM 7
LIGHTING SYSTEM WITH PRESENCE AND LIGHTING SENSORS - LARGE MEETING ROOM
The SCS 1-10 V dimmer, item                        the room for optimum detection, and                         the blackboard (circuit 3) and
BMDI1002, manages all the room                     automatically disables the general                          the general lights (circuit 1), are
lighting circuits: switching on/off                lighting of the room (circuit 1) based                      managed using the 3 module SCS
the lamps of the screen (circuit 2)                on the detection of presence and the                        control, item H4652/3.
and the blackboard (circuit 3), and                level of natural light.                                     The shutters (circuit 5, 6 and 7) and
adjusting the general lighting of the              It is also possible to manually adjust                      the screen up and down control
room (circuit 1).                                  the light using one of the 3 module                         (circuit 2) are controlled by three SCS
The SCS double technology sensor,                  SCS control buttons, item H4652/3,                          actuators, item F411/2, and adjusted
item BMSE3003, configured in ECO                   installed at the entrance.                                  using the special SCS control, item
mode, is installed at the centre of                The lights of the screen (circuit 2),                       H4651M2.
L                                                                                                                                                                L
N                                                                                                                                                                N
                Motor for             Motor for              Motor for                 Motor for   Central              1 Halogen for        1 Halogen for
                shutters              shutters               shutters                  screen      lamps 10 x 72 W      screen               blackboard
                      7                      6                    5
                                                                                            4                  1                      2                      3
Warning:
1. 	To ensure optimum detection, install the       3. 	Connect together all the devices using                  5. 	The sensor has the following factory
    double technology ceiling SCS sensor,              the SCS cable, item L4669, L4669/500,                       settings: delay time 15 minutes, brightness
    item BMSE3003, at the centre of the room;          L4669HF.                                                    threshold 500 lux, maximum PIR sensitivity
    install the three module SCS control, item     4. 	Configure sensors, controls and controller                  and high US. Whenever necessary
    H4652/3; install the special SCS control,          using the MyHOME_Suite software.                            use the configuration remote control
    item H4651M2, between the screen and the                                                                       item BMSO4001 to change the sensor
    shutters.                                                                                                      parameters.
2. 	Install the 2-channel SCS actuators item
    F411U2 + the 1-10 V 4 channel dimmer,
    item BMDI1002 + the SCS power supply
    unit, item E46ADCN, in a cabinet.
     DIAGRAM 8
     LIGHTING SYSTEM WITH PRESENCE AND LIGHTING SENSORS - HALL AND RECEPTION
     Each passive infrared ceiling                  amount of natural light: sensors are
     sensor, item BMSE3001, or double               configured to keep a 500 lux level in
     technology sensor, item BMSE3003,              the reception and a 100 lux level on the
     controls the corresponding zone                staircases.
     (circuit 1, 2 and 3).                          The light can also be switched on using
     During the day, the illumination is            the touch screen, item H/LN4890.
     automatically adjusted based on
     presence or movement, and the
     L1
     L2
     N
                                                                                 Circuit 1           Circuit 2                  Circuit 3
                     Item
                     E49                                               Item                                           Item
                                                                       F417U2                                         F416U1
                             BUS/SCS cable
                                                                                                                  Item
                                                                                                                  LN4890
                                     Item           Item              Item
                                     BMSE3001       BMSE3003          BMSE3003
     1. 	Install the double technology or passive   3. 	Install the SCS touch screen, item LN4890,       6. 	The sensors have the following factory
         infrared SCS ceiling sensors, items            on the wall.                                         settings: delay time 15 minutes, brightness
         BMSE3003 and BMSE300, at the centre of     4. 	Connect all the devices together using               threshold 500 lux, maximum PIR sensitivity
         each of the areas to control.                  the SCS cable, item L4669, L4669/500,                and high US.
     2. Install the SCS power supply unit, item         L4669HF.                                         	 Whenever necessary use the configuration
        E46ADCN, and the SCS dimmers, items         5. 	Configure all the installed devices using the      remote control item BMSO4001 to change
        F417U2 and F416U1, in the hall patch            MyHOME_Suite software.                             the sensor parameters.
        cabinet.
68
CONTENTS
                 MyHOME_Up – Temperature control
                 General features. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 70
                 General rules for installation. .  .  .  .  .  .  .  .  .  . 76
                 Wiring diagrams . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 78
Temperature control
     The MyHOME temperature control               With the installation of the                 With the integration of the Driver
     system includes the following                MyHOMEServer1 gateway, the                   manager, item F459, it is possible
     devices:                                     system can also be managed                   to manage third-party heating and
     - Probes with and without display            using the HOMETOUCH touch                    cooling systems using the mentioned
     - Actuators                                  screen, or the Smartphone with               devices.
                                                  the MyHOME_Up App.
                                                  IT is also possible to define
                                                  programs for the activation of the
                                                  heating system based on custom
                                                  profiles.
                                                                                                       HOMETOUCH 7”
                                                  Zone 1                        Zone 2
     Power supply                                 probe                         probe
MyHOMEServer1
                                                                                               Cold
                                 M
                                0-10V
                                                                                               Hot
70
THE PROBES
Temperature control
     THE ACTUATORS
     Manufactured for installation in DIN switchboards, these devices control
     the solenoid valves and the pumps of the temperature control system.
     The range is below:
                                                                                                                Actuator
     With NA contact relay output,                                                                              with 2 contacts
                                                                                                                item F430/2
     item F430/2 (2 contacts), item F430/4 (4 contacts) and item F430R8
     (8 contacts), for the control of ON/OFF valves and pumps. If the
     system includes fan-coils, the fan speed can also be adjusted.
                                                                                                   OUT 3
                                                                                                   OUT 2
                                                                                                   OUT 1
                                                                                                   OUT 5
                                                                                                   OUT 4
                                                                                                                                           N
                                                                                                                                           L
                                                                                                           L1                       L2
                                                                 OUT 3
                                                                 OUT 2
                                                                 OUT 1
                                                                  N
                                                                 OUT 5
                                                                 OUT 4
                                                                                                                                  F430R8
Use of the F430/8 actuator, for the control of a 4-tube and 3-speed fan-coil.
72
With output voltage 0-10 V
item F430R3V10 (also with 3 NC contacts) and item F430V10, for the control of proportional solenoid valves,
type 0-10.
                                                                                                 OUT 3
                                                                                                 OUT 2
                                  M 0 – 10 V                                                     OUT 1
                                                                                                                                N
                                  M 0 – 10 V                                                                                    L
                                                                                                         L1
                                                               OUT 3
                                                               OUT 2
                                                               OUT 1
                                                                 N
                                                                        –
                                                                          5
                                                                        +
                                                                          6
                                                                        –
                                                                          7                                         F430R3V10
                                                                        +
                                                                          8
Use of the F430R3V10 actuator for the control of one 4-tube fan-coil with 0-10 3-speed valves.
Temperature control
Actuators
                                                      1    2    3   4          1   2   3     4   5
                                                      1 2 3 4                 1 2 3 4 5
C1 C2 C1 C2 C3 C4
ON/OFF
                          OPEN/CLOSE
      VALVES
                          3 POINTS
0-10V
2 ON/OFF TUBES
4 ON/OFF TUBES
4 TUBES 3 POINTS
ELECTRICAL HEATING
CLIMAVENETA
Note 1): Changing the speed using the probes is not possible
74
                                  Probes
1)
1)
1)
Temperature control
                                               following rules:
                                                                                                                                                                                1 2 3 4
     SYSTEM PHYSICAL
     EXPANSION
     Particularly extended systems,
     or systems with overall device                                                                                                                     1    2    3   4
ART. F430/2
AR T.F422 AR T.F422
     that:
     - It is not possible to connect two
       interfaces in parallel on the
       same BUS;
     - It is possible to install up to 4
       interfaces to split the system
       into 5 separate sections.
MyHOMEServer1
76
 ASSOCIATION OF THE DEVICES
 This operation defines:
 - the logic link between a probe and the corresponding actuator that must be managed;
 - the operating mode of probes and actuators based on the type of temperature control system to manage.
 As for the light and shutter automation system, this function is carried out when putting the system into operation
 and using the MyHOMEServer1 web server and the MyHOME_Up smartphone App.
For the list of the devices compatible with this mode, refer to the APPENDIX section at the end of the guide.
                                           Actuator
                                                      H/LN4691
                                           F430R3V10      Probe
                           ZONE 4                                               Ground...          Kitchen            Ground...           Kitchen
OK Add device
                                          F430R3V10       Probe
                           ZONE 2
                                           Actuator
                                                                     FAN-COIL
       LAN network                                    H/LN4691       SYSTEM
                                                                     E46ADCN
                                                          Probe
        MyHOMEServer1
                                          F430R3V10
                           ZONE 1
MyHOMEServer1                                                        Power supply
Temperature control
     DIAGRAM 1
     4 ZONE VILLA - HEATING BY MEANS OF RADIATOR WITH 0-10 V SOLENOID VALVES
                                                                                                           -                  + -                +      -   + -    +
                                                                                                           OUT 1OUT 2                                   OUT 1OUT 2
Actuator Actuator
                                  0 to 10
                              Solenoid valve              ZONE 4                      H/LN4691
Probe
                                   0 to 10                                                                 BUS
                               Solenoid valve             ZONE 3                      H/LN4691
                                                                              Probe
                                                                                                           MyHOMEServer1
                                                                                                                                                               E46ADCN
                                  0 to 10
                              Solenoid valve              ZONE 2                      H/LN4691                                MyHOMEServer1
                                  0 to 10
                              Solenoid valve              ZONE 1                      H/LN4691
                                                 L                                                                                     Actuator
                                                 N
                                                                                                           1    2    3   4
                                                                                                           1 2 3 4
ART. F430/2
C1 C1 C2
F430/2
                                                            Circulation
                                                            pump
                                                                             Boiler
     WARNING: The diagrams, showing Axolute and Livinglight, also apply, when possible, to MyHOME_Up products, Living Now series.
     For further information, see the Technical sheets of every item available in the bticino.com site.
78
DIAGRAM 2
4 ZONE VILLA - HEATING BY MEANS OF RADIATORS WITH ON/OFF SOLENOID VALVES
C4 C3 C2 C1
                                                                                                                      F430/4
                                                                                            1    2      3    4   5
                                                                                            1 2 3 4 5
                         ZONE 4   Probe
        Solenoid valve
H/LN4691
                         ZONE 3   Probe
        Solenoid valve
BUS
                                          H/LN4691
                                                          MyHOMEServer1
                         ZONE 2   Probe                                                                                   E46ADCN
        Solenoid valve
                                                                       MyHOMEServer1
                                          H/LN4691
                                                                                                            Power supply
                                  Probe
                         ZONE 1
        Solenoid valve
                                                              1    2     3   4
                                                              1 2 3 4
ART. F430/2
                                                              C1   C2
                                                                                       Actuator
F430/2
                                                     L
                                                     N
                                                                                 C1
                                                          Circulation
                                                          pump
                                                                                                                 Boiler
Temperature control
     DIAGRAM 3
     4-ZONE VILLA - HEATING AND COOLING WITH 4-TUBE FAN-COILS, WITH 0-10V SOLENOID
     VALVES OR WITH 0-10 SPEED ADJUSTMENT.
                                               Actuator
                                                            H/LN4691
                                                F430R8            Probe
                       ZONE 4
                                               Actuator
                                                            H/LN4691
                                                F430R8            Probe
                       ZONE 3
                                               Actuator
                                                                                   BUS
                                                            H/LN4691
                                                F430R8            Probe
                       ZONE 2
E46ADCN
                                                F430R8            Probe
                       ZONE 1
Power supply
Boiler
Chiller
Note: 0-10V valves are not managed in proportional mode, but in ON-OFF mode
80
Actuator connection
F430R8
                                                                          2
                          M                                               3
                         0 to 10                                          4
                                                                                      1
                          M                                                       L1
                         0 to 10
                                                                              N
                                             M
                                                                                  5
                                                                                  6
Variation for the connection of a 4-tube fan-coil with 0-10 V speed adjustment
- use of two 0–10 V outputs (set LOAD = 3 in case of physical configuration).
M N
                                                       Control
                                             M           unit
                                                                    VC
                                                                    VH
                                                     -+        -+   COM
                                                 H     0 – 10 V C
                      VH= heating valve
                      VC= cooling valve
                      COM= common entrance
F430R3V10
Temperature control
     DIAGRAM 4
     3-ZONE VILLA - INTEGRATION OF THE TEMPERATURE CONTROL SYSTEM WITH RADIANT
     PANEL HEATING SYSTEMS AND DAIKIN VRV COOLING (IP PROTOCOL)
                                                                 F430/4
                                                                                            1    2      3    4       5
                       Daikin VRV
                                                                                            1 2 3 4 5
ART. F430/4
internal unit C1 C2 C3 C4
C1 C2 C3 C4
                                 ZONE 3
                                                                              H/LN4691
                                             VRV internal unit                                              MODE
           Dill-Net
                                                                                                             FAN
                                 ZONE 2
                                                                                  H/LN4691
                                             VRV internal unit
                                                                                                             MODE
Dill-Net FAN
                                 ZONE 1
                                                                                  H/LN4691
                                             VRV internal unit
                                                                                                             MODE
Dill-Net FAN
                                                                   C1
                      Intelligent                                                           F430/2
                      Touch Controller                              1    2    3   4
                                                                   1 2 3 4
                                                                                                                           E46ADCN
                                                                              ART. F430/2
C1 C2
Dill-Net
                                                                                                                         SCS
                      Switch
                      Ethernet
                                                                                                                                      Mixing
                                                                                                                                      valve
                                                                                                                     C1
                      LAN                                                                                                              M
                                            Driver
                                            manager
                                            F459
                                 ETHERNET
SCS AI SCS AV
                                                       SCS
                                                                                                                                                         L
                                                                                                                                                         N
82
CONTENTS
               MyHOME_Up - Load control and consumption display
               General features. .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 84
               Wiring diagrams . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 89
     The load control Management system manages the maximum power used, by automatically disconnecting the
     least important appliances in case of overload.
     OPERATION                                      In the example shown, the oven,                   The microwave is on the other
     The control unit measures the                  the microwave and the washing                     hand the appliance with the highest
     power absorbed by the connected                machine represent the loads                       importance, with priority level 3, and
     loads and compares it with the                 controlled through actuators, while               only disconnects after the oven and
     preselected value (between 1.5 and             the refrigerator, the operation of                the washing machine.
     18 kW, with tolerance +/- 20%).                which must never be stopped, is                   The status of the disconnected
                                                    connected to the socket without                   appliance is displayed on the
     Each load to control is associated
                                                    actuator.                                         7” HOMETOUCH touch screen
     with an actuator managed by the
     control unit, which disconnects the            In case of overload, the first                    and on the digital controls, item
     load from the network in case of               appliance that disconnects is the                 KW/KG/KM8011, through LED
     overload.                                      least important one; in this example              pictograms.
                                                    this is the oven, which has a priority            The device can be reactivated
     The load disconnection sequence
                                                    level of 1.                                       using the button of the actuator,
     can be configured during
     installation; it is possible to manage                                                           using the 7” HOMETOUCH touch
     up to 63 priority levels (actuators).                                                            screen, and the digital controls,
                                                                                                      item KW/KG/KM8001.
                                                                                                      If after reactivation the overload
                                                                   Central unit for load
                                                                   management                         persists, the control unit
                                                                                                      disconnects the loads with priority
                                                                                                      levels 2 and 3, until the overload
     Electrical counter                                                                               situation is resolved,
                                                                            HOMETOUCH
                          Electrical switchboard
BUS SCS
230 Va.c.
84
Consumption display and energy production
Inverters
Music
Coloured light
Light
Rolling shutter
MyHOME_Up App
                                          SCS/BUS
                                         connection
                                             Configurator
                                              socket door
                                                                                                 SCS/BUS
                                                                                                connection
86
16A actuator with current sensor item F522
Device equipped with 1 10A bistable relay with zero                                                                   230 Va.c.
crossing functionality for the load control management                                                              connection
and/or automation functions, with the same modes of the
flush mounted actuator, item .....4672N.
The actuator can be used for the measuring of the
electricity, as it is fitted with an internal current sensor for
                                                                                   Device status
the measurement of the consumptions of the controlled                              LED
                                                                                                                 Load forcing
load and, in conjunction with the external optional toroid,
                                                                                                                  pushbutton
item 3523, for the measurement of the earth leakage
current of the diagnostic system.
                                                                                   Configurator
                                                                                   socket door
DEVICE SELECTION
   Available functions                                                        Devices
                              Energy meter     Central unit   Actuator 16A   16A actuator        Flush
                               item F520          for load    with current    item F523        mounted          Living Now Full control
                                               management        sensor                            16A              item ...8011 and
                                                item F521      item F522                       actuator               Touch screen
                                                                                                  item                HOMETOUCH
                                                                                               ...4672N
Display
Load control
 Diagnosis 1)
 Note 1): in combination with optional toroid 3523
     The maximum number of devices        If the system shares the same cable        When sizing the system, it is also
     in a system depends on the total     of the Automation/Temperature              necessary to consider the length of
     absorption of the same and the       control system, the calculation of         the cable, complying with the follow-
     distance between the point of        the maximum number of devices              ing rules:
     connection and the power supply.     must be completed taking into              - 	The connection length between
     With absorption levels below         account the general absorption of             the power supply and the furthest
     600 mA, it will be possible to use   the same.                                     device must not exceed 250 m.
     compact power supply E49. With
                                          For the purpose of the above               - 	The total length of the connections
     absorption levels between 600 and
                                          calculations, refer to the absorption         must not exceed 500 m (cable
     1200 mA, power supply E46ADCN
                                          values indicated on the technical             extended).
     must be used.
                                          data sheets of the devices, available      - 	For optimum division of the
                                          in the on-line catalogue that can be          currents on the bus line it
                                          found at bticino.com.                         is recommended that the
                                                                                        power supply is installed in an
                                                                                        intermediate position.
                                                                    A	      =	250 m max
                                                         A          B	      =	250 m max
                                                                    A + B 	=500 m
                                                                    Maximum current provided by the power supply:
                                                         B          1200 mA for item E46ADCN and 600mA for item E49.
     Power supply
                                                                    Note: If a UTP5 cable is used in alternative to the L4669
                                                                    BUS cable, distances are halved.
88
WIRING DIAGRAMS
                                                                                                                                        Load
                                                                                         Load   Load
                                                       L N
                                                                                                                                   ...4672N
                                                          Central unit
                                                             for load                Actuator    Actuator                                      HOMETOUCH
                                       E49               management                  16 A        16 A                              A                 3488
            PRI
                                                                 F521                F523        F523                     A    =    0
                                       Compact
                                                                                      A = 0       A = 0
            E49
            PRI: 220 – 240 V~
                 185 – 175 mA
                 50/60 Hz
                                       power supply           A1    =   0                                                 PL   =    0
                                                                                      PL = 0      PL = 0
            SCS: 27 Vdc
                                                                                                                          G    =    0
                 600 mA
                                                              A2    =   0
                                SCS
                                                                                      G = 0       G = 0                   M    =    0
                                                              A3    =   1
                                                                                      M = 0       M = 0                   P1   =    0
                                                              P     =   0
                                                                                      P1 = 0      P1 = 0                  P2   =    3
                                                              HST   =   5
                                                                                      P2 = 2      P2 = 1
BUS/SCS
                                                                                                      Single                    Single
                                                                     R N                              phase                     phase
                                                                                                      load                      load
                 E49
                 PRI: 220 – 240 V~
                      185 – 175 mA
                      50/60 Hz
                 SCS: 27 Vdc
                                                 A3 = 1    P2 = 1                            P2 = 2                    P2 = 3
                      600 mA
BUS
                                                 F521      F523
                                                                                                                  Energy display
                                                                                    R N
                                                                                                                  H/LN4710
                                                                                                           TIME
                                                 A3 = 2    P2 = 1
                                                 PHASE S   PHASE 2
FC4A...
F521 F523
                                                                                                                                      Three-phase load
                                                 A3 = 2    P2 = 1          NOTE: 1) configurators must be selected
                                                                           based on the contract power.
                                                 PHASE T   PHASE 3
CAUTION
90
           MyHOME_Up - Function integration
Function integration
     The integration of the various home automation                                 The integration also allows to control all the home
     functions allows to set advanced functions that could                          automation functions through central control
     not be possible with a traditional system.                                     devices, such as the HOMETOUCH Touch Screen, or a
                                                                                    Smartphone with the MyHOME_Up supervision App.
     For example it is possible to:                                                 With MyHOME_Up it is possible to have two types of
     - create advanced functions, such as switching on all                          integration:
       the lights following an intrusion alarm;
     - create scenarios for the simultaneous activation of
       several devices of the MyHOME_Up system for the
       creation of comfort situations.
HOMETOUCH
                                               Integrated MyHOME_Up
                                                      functions
Music
Coloured light
Light
Rolling shutter
MyHOME_Up APP
92
1.	Integration of two or more MyHOME_Up functions, such as the light
   automation system with the temperature control system, or the load
   management system.
                                                         Air conditioning
                                                                systems
MyHOMEServer1
                                                                Management of
                                                               weather stations
                                                                   and sensors
Function integration
                                                                                                                                                                       TV/SAT                   IPTV
                                                                                                                                                                                                                   Energy
                                   Automation                                                                                                                                                                    Management
automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www irrigazione
Music
Coloured light
Light
Rolling shutter
      MyHOME_Up APP                                       WiFi Modem router                       MyHOMEServer1 for control with Smartphone
                                                                                                  and MyHOME_Up app
94
“Physical separation” mode
In case of need of splitting the system in order to
achieve the current absorption values, or to keep them
separate, interface F422 must be used in “physical
separation” mode.
                          Energy
                        management
                          system
                                                                              Automation
                                                                                system
F422 interface
                                                                                                              230 Va.c.
                                                  IN
Music
Light
MyHOME_Up APP
Function integration
                                       Video door
     Power supply                     entry system
                                                           SCS interface
                                                  OUT      MOD=0                    Light          Shutter                                           Temperature                                   Temperature
     230 Va.c.                                                                      control        control                                           probe                                         probe
IN
                                                               230 Va.c.
                                                                                                                                                                                                                                BUS SCS
                                                                                                                                                                                      TV/SAT                  IPTV
automazione diffusione sonora antifurto termoregolazione videocitofonia controllo lan controllo carichi energia luci tvcc www
Light
Rolling shutter
                                                          MyHOMEServer1 for
                                                          control with Smartphone
     MyHOME_Up APP                                        and MyHOME_Up app
96
A2. Use of HOMETOUCH Touch Screen
When managing home automation                        The MyHOMEServer1 gateway must
and video door entry system                          also be installed in the system, for
functions using the HOMETOUCH                        the integrated management of the
touch screen, interface F422 is not                  Automation, Temperature control
required.                                            and Video door entry system for the
In this case, the integration is                     association of the devices.
completed from HOMETOUCH                             Function control can be completed
connected to the Automation and                      locally or remotely using the
Video door entry system BUS.                         Smartphone, with the MyHOME_Up
                                                     and Door Entry Apps.
TV/SAT IPTV
Music
Light
Function integration
                                                                                                                                                     Burglar alarm
                                                                  Volumetric sensors
Siren
                                                                                     BUS SCS
     230 Va.c.
                         Dimmer        2 relay             Temperature              Temperature control
                         actuator      actuator            control actuator         actuator
LAN network
Music
Coloured light
Light
                  Video door
                                                                                                                     Rolling shutter
                                                                  LAN network
                 entry system
                                                                                                                     MyHOME_Up APP
                                                                                WiFi Modem router
                                               MyHOMEServer1 for control
                                               with Smartphone and
                                               MyHOME_Up app
98
 This page shows another example of integration through the LAN
 network of Automation, Temperature control, NUVO multiroom audio
 system, and lighting with Philips HUE lamps.
1-zone player
                                                                                BUS SCS
 230 Va.c.                                                                                             NUVO player
LAN network
Music
Coloured light
Light
Rolling shutter
                                                                LAN network
                                                                                                           MyHOME_Up APP
Function integration
                                                        Specific driver
                                                        for application
      MyHOME_Up                                                                                 ■ 	SAMSUNG
                                                                                                ■ 	OREGON SCIENTIFIC
                                                                                                ■	 ...........
                                                                                  To the DALI
                                                                                    devices
      Power supply
                                                        Actuator
230 Va.c.
                                              MyHOME_Up
                                                system
100
E. Integration using the Application Programming Interface (API)
API integration can be made in two      This is the open interoperability           For more details please
ways:                                   platform, a strategic part of the Eliot     visit: www.bticino.com
- interoperability through the          program (program of the connected
  sharing of different languages on     objects of the Legrand group).
  the IP level (local and through the   Compatible with the main IoT world
  cloud).                               players, it gives the possibility
- interoperability through IOT Cloud    of connecting with the Legrand
  platforms, for example Artik          ecosystem in several ways, allowing             WORKS WITH
  Samsung and similar.                  small and large developers to
Works With Legrand is available for     interact with MyHOME_Up.
professionals that must use this
integration solution.
102
GENERAL FEATURES
The HOME configurator is a tool                  - MyHOME_Up BUS, and to                          which can be changed at any time,
that helps the installer or the                    customise the control/device points            and saved in the MyBTicino personal
final use to correctly estimate                    in the various finishes: Axolute,              area. If the system is a MyHOME_Up
an electric system, either                         Màtix, Livinglight and Living Now.             system, also the total system current
traditional, traditional with                    With this simple information, the                consumption will be supplied, for
connected Smart devices, or                      application will provide the value for           the appropriate checks at the design
MyHOME_Up BUS.                                   the total system, or split into rooms,           stage.
The application, available after
free registration on the
https://my.bticino.it website,
offers a range of “standard
homes” that can be modified
based on specific needs. For each
home the functions to value can
also be defined.
- Driving force and services;
- Light;
- Shutters;
- Temperature control;
- Consumption display;
- Electric panel;
- Protections.
After selecting the function, the
application requires the definition
of the system technology:
- traditional;
- traditional with connected
                                             Definition of the functions to value.
  Smart devices;
NOTE: to ensure constant product improvement, this software may be subjected to revision.
We therefore recommend that the my.bticino.it website is checked regularly to make sure to obtain the most recent version of the web application.
YouDiagram software
      NOTE: to ensure constant product improvement, this software may be subjected to revision.
      We therefore recommend that the my.bticino.it website is checked regularly to make sure to obtain the most recent version of the web application.
104
MyHOME_SUITE
MyHOME_Suite is the application that can be used in alternative to the MyHOME_Up App to assign functions
to the devices of the Automation, Energy management and Temperature systems.
  On-line
  update            Icon for the consultation                               Web Server IP address
  icon              of the software integrated                              and connection status
                    user guide                                                             display
        List of                    Working area for the collection of the                       Selection of the parameters for the
     configurable                      system devices to configure                             configuration of the address and the
        items                                                                                             operating mode
CUSTOMER SERVICE
                                                                   MYOPEN COMMUNITY
                                                                  The home automation system
                                                                  integrator community, with detailed
                                                                  information and services relating to
                                                                  new applications.
                                                                  www.myopen-legrandgroup.com
106
CONTENTS
           MyHOME_Up catalogue . .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 108
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . 138
108
                                                        NOTE:      White device                     Tech device               Anthracite device                   Neutral item
LIVING NOW DIGITAL DEVICES FOR LIGHTS AND SHUTTERS
                             CONNECTION MODULES
   K8001                     device for the power supply of controls through
                             electrified frame
                             item KW/KG/KM8103......8104.....
      Item                    CONTROLS FOR SINGLE OR DOUBLE LOADS                  Item                         CONTROL FOR SPECIAL FUNCTIONS
                              control which can drive a single actuator for                                     control for the management of one or two ON/
                              single or double loads or two actuators for                                       OFF functions, the shutter UP/DOWN function
                              single loads or independent double loads – to                                     and the adjustment of a dimmer load. It can also
                              be completed with 1 2-module key cover for                                        be used as scenario control and for the call to the
                              controls with one or two functions or 2 1-module                                  floor, staircase light switching on and door lock
                              key covers with one or two functions - 2 modules                                  activation functions. It manages advanced shutter
         H4652/2              Axolute                                                                           functions. - 2 modules.
         L4652/2              Livinglight                                                                       To be completed with 1 or 2-module covers.
                                                                                      K4652M2                   Living Now
         AM5832/2             Màtix
                              control which can drive three actuators for single
                              or double loads or two actuators for single loads                                 Control for the management of up to three
                              or independent double loads – to be completed                                     separate functions as described above - 3
                              with 3 1-module key covers for controls with one                                  modules. To be completed with 1 or 2-module
                              or two functions - 3 modules                                                      covers.
         H4652/3              Axolute                                                 K4652M3                   Living Now
         L4652/3              Livinglight
         AM5832/3             Màtix
110
                                               NOTE:     White device                     Tech device             Anthracite device                      Neutral item
LIGHTS AND SHUTTER AUTOMATION
Control
                         Energy saving             LED lamps             Linear fluorescent      Compact fluorescent      Electronic transformers Ferromagnetic          Reducer motors
                         incandescence and                               lamps 1)                lamps                    3)
                                                                                                                                                  transformers 2) 3)     for shutters 4)
                         halogen lamps
      H4672M2            1380 W                    250 W                 250 VA                  250 W                    460 W                    460 VA                460 W
      LN4672M2                                     Max 2 lamps                                   Max 2 lamps
      AM5852M2
      K4672M2L
      3476     2A                                  40 W                  -                       40 W                     -                        2 A cosφ 0,5          -
                460 W                              Max 1 lamp            -                       Max 1 lamp               -                        460 VA                -
      H/L4661M2 -                                  -                     -                       -                        -                        -                     2 A 250 Va.c.
      AM5861M2
      K4672M2S
      Notes:
      1) 	 Power factor corrected fluorescent lamps, discharge lamps.
      2) 	 Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator. For example if a dimmer is connected to a 100 VA ferromagnetic
      transformer with yield 0.8, the effective power of the load will be 125 VA.
      3) 	 The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
      parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
      4) The          symbol on the actuators refers to the shutter reducer motors.
112
                                                            NOTE:       White device                        Tech device                     Anthracite device                    Neutral item
LIGHTS AND SHUTTER AUTOMATION
                        Energy saving incandescence   LED lamps       Linear fluorescent     Compact fluorescent    Electronic transformers Ferromagnetic           Reducer motors
                        and halogen lamps                             lamps 1)               lamps                  3)
                                                                                                                                            transformers 2) 3)      for shutters 4)
 F411U2                 10 A                          250 W           4A                     250 W                  4A                      4 A cosφ 0,5            2A
                        1380 W                        Max 4 lamps     230 W                  Max 4 lamps            230 W                   460 VA                  460 W
 F411/4                 2A                            70 W            0.3 A                  70 W                   0.3 A                   2 A cosφ 0,5            2A
                        460 W                         Max 2 lamps     70 W                   Max 2 lamps            70 W                    460 VA                  460 W
 BMSW1003               16 A                          2.1 A           10 X (2 X 36 W)        1150 W                 16 A                    16 A                    -
                        3680 W                        500 VA          4.3 A                  5A                     3680 W                  3680 W                  -
 BMSW1005               16 A                          2.1 A           4.3 A                  5A                     16 A                    16 A                    -
                        3680 W                        500 VA          10X2X36 W              1150 VA                3680 W                  3680 W                  -
 F401                                                                                                                                                               2 A 250 Va.c.
Notes:
1) 	 Power factor corrected fluorescent lamps, discharge lamps.
2) 	 Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator. For example if a dimmer is connected to a 100 VA ferromagnetic
transformer with yield 0.8, the effective power of the load will be 125 VA.
3) 	 The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
4) The          symbol on the actuators refers to the shutter reducer motors.
                           Energy saving incandescence LED lamps             Linear fluorescent lamps 1)     Compact fluorescent    Electronic      Ferromagnetic          Reducer motors
                           and halogen lamps                                                                 lamps                  transformers 3) transformers 2) 3)     for shutters 4)
      BMDI1002             Dimmer for ballast - 4 x 4.3 A outputs - 4x 1000VA@ 230 Vac - 4x500VA@ 230 Vac
      F413N                -                                -                2 A 460 W 5)                    -                      -                -                     -
                           -                                -                Max 10 ballast, type T5, T8,    -                      -                -                     -
                                                                             compact or driver for LED
      F414                 0.25 - 4.3 A                     -                -                               -                      -                0.25 - 4.3 A          -
                           60 - 1000 VA                     -                -                               -                      -                60 - 1000 VA          -
      F416U1               4.3 A                            -                -                               -                      4.3 A            4.3 A                 -
                           40 - 1000 W                      -                -                               -                      40 - 1000 W      40 - 1000 W           -
      F418U2               2x300 W                          2x300 VA         -                               2x300 VA               2x300 VA         2x300 VA              -
      F429                 SCS/DALI dimmer interface - 8 x16 ballast
      Notes:
      1) 	 Power factor corrected fluorescent lamps, discharge lamps. 2) Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator.
      For example if a dimmer is connected to a 100 VA ferromagnetic transformer with yield 0.8, the effective power of the load will be 125 VA.
      3) 	 The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
      parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
      4) The          symbol on the actuators refers to the shutter reducer motors. 5) Only compatible with lamps with 1/10 V ballast.
114
                                                             NOTE:      White device                         Tech device                      Anthracite device                   Neutral item
   LIGHT SENSOR
   Item                              PIR+US DOUBLE TECHNOLOGY GREEN SWITCH              Item                                PIR PASSIVE INFRARED GREEN SWITCH
                                     Green Switch: double technology presence                                               Green Switch: passive IR (PIR) sensor, suitable
                                     sensor, passive IR and ultrasound (PIR+US),                                            for the detection of presence in transit areas
                                     suitable for the detection of presence in                                              (corridors, toilets, service rooms). Operating mode
                                     working areas (offices, meeting rooms). With                                           (automatic or manual), time delay (5 s to 59min),
                                     manual ON/OFF pushbutton. Operating mode                                               and brightness threshold (20 to 1275 LUX)
                                     (automatic or manual), time delay (5 s to 59                                           settable using the advanced/basic (BMSO4001/
                                     min), and brightness threshold (20 to 1275 LUX)                                        BMSO4003) configuration remote control;
                                     settable using the advanced/basic (BMSO4001/                                           physical or virtual configuration. 2 modules
                                     BMSO4003) configuration remote control;                  HD4659                        Axolute
                                     physical or virtual configuration. 2 modules             HC4659
       HD4658                        Axolute                                                  HS4659
       HC4658                                                                                 N4659N                        Livinglight
       HS4658                                                                                 NT4659N
       N4658N                        Livinglight                                              L4659N
       NT4658N                                                                                AM5659                        Màtix
       L4658N                                                                                 K4659                         Living Now
       AM5658                        Màtix
   DIAGRAM FOR THE USE OF THE GREEN SWITCH, ITEM L/N/NT4658N                                                   ECO MODE
                                                                                                               Manual load activation and automatic switch off managed by the
                                 Green Switch                                                                  dimmer/actuator based on the detection of the presence of people
   Power supply                  control item       Dimmer item F416U1
                                 L4658N                                                                        and the desired level of illumination detected by the control, item
                                                                                                 L4658N. The function of the control is first of all to activate the automatism of
                                                                                                 the dimmer/actuator: upon first pressure, the sensor compares the desired light
                                                                                                 level with the actual light level of the room, and ascertains if the light should be
                                                                                                 switched on or not. A subsequent pressure of the control forces the switching ON
                                                                           Lighting devices      or OFF of the automatism determined by the dimmer/actuator.
116
                                                 NOTE:      White device                     Tech device                     Anthracite device                 Neutral item
TEMPERATURE CONTROL
   KM4691                                                                                 F430R8
                                                                                                                     control of on-off valves, motorised valves (open-
                                                                                                                     close and three points), pumps and fan coils with
                               SLAVE PROBE                                                                           2 and 4 tubes - 4A resistive, 1A motor valves,
                               probe to control the room temperature for                                             pumps and fan-coils- SCS-bus connection - 4 DIN
                               heating and cooling systems – temperature                                             modules
                               measurement range 3–40 °C                                  F430R3V10                  actuator with 3 independent relays and 2 x 0-10
                               - 2 modules                                                                           Volts outputs for the control of fan coils with 2
   HD4693                      Axolute                                                                               and 4 tubes with proportional 0-10 Volt valves -
   HC4693                                                                                                            4A resistive, 1A fan coil - SCS-BUS connection - 4
   HS4693                                                                                                            DIN modules
   N4693                       Livinglight                                                F430V10                    actuator with 2 x 0-10 Volt outputs for the control
   NT4693                                                                                                            of 0-10 proportional valves - SCS-BUS connection
   L4693                                                                                                             - 2 DIN modules
NOTE: White device Tech device Anthracite device Neutral item sand device
118
                                        NOTE:      White device                      Tech device             Anthracite device                  Neutral item
COMMON ACCESSORIES AND DEVICES
                                                                            System	                                      Cable
                                                                            	                                            L4669 		   336904	
                                                                            	                                            L4669/500	
                                                                            	                                            L4669KM1
                                                                            	336905
                                                                            Automation	                               •   •		 (1)
                                                                            Energy Management/Consumption Display	    •		 •          (1)
                                                                            Temperature control	                      •		 •          (1)
                                                                            Video door entry system			                    •
                                                                            NOTE (1): for systems underground cable sections
      COVER FOR ACTUATOR ITEM K4672M2L,                               COVER FOR ACTUATOR ITEM K4672M2S,
      CONTROLS ITEM K4652M2 AND ITEM K4652M3                          CONTROLS ITEM K4652M2 AND ITEM K4652M3
120
                                                           NOTE:   White device               sand device   black device
LIVING NOW KEY COVERS
COVERS FOR ACTUATOR ITEM K4672M2L AND                                      COVERS FOR ACTUATOR ITEM K4672M2S AND
CONTROL ITEM K4652M2                                                       CONTROLS ITEM K4652M2
KM01MH2F KW01MH2X
2-FUNCTION NON-SILK-SCREEN PRINTED KEY COVERS 2-FUNCTION NON-SILK-SCREEN PRINTED KEY COVERS
HD4915 HD4915M2 N4915LN N4915M2LN AM5911* HD4911 HD4911M2 N4911N N4911M2N AM5911/2*
               NON-SILK-SCREEN PRINTED KEY COVERS - 1 FUNCTION                         NON-SILK-SCREEN PRINTED KEY COVERS - 2 FUNCTIONS
               1 module                      2 modules                                  1 module                      2 modules
               Item                                  Item                                 Item                                      Item
               Axolute                                                                    Axolute
               HD4915                                HD4915M2                             HD4911                                    HD4911M2
               HC4915                                HC4915/2                             HC4911                                    HC4911/2
               HS4915                                HS4915/2                             HS4911                                    HS4911/2
               Livinglight                                                                Livinglight
               N4915LN                               N4915M2LN                            N4911N                                    N4911M2N
               NT4915N                               NT4915M2N                            NT4911N                                   NT4911M2N
               L4915N                                L4915M2N                             L4911N                                    L4911M2N
               Màtix                                                                      Màtix
               AM5911*                               AM5911/2*                            AM5911*                                   AM5911/2*
           * key cover that can be used for 1 and 2 functions                                                          NOTE: the control keys are supplied with
                                                                                                                       the device.
upper pushbutton
                                                                                                                                                 control
                                                                                                           lower pushbutton                      key
                                                                                                           LED
                                                                                                                                                                  key cover
                                                                                                                                                                  2 functions
                                                                                                                                                                  2 modules
                                                                                                                                    key cover
                                                                                                                                    1 function
                                                                                                        key cover                   2 modules
                                                                                           key cover    2 functions
                                                                                           1 function   1 module
                                                                                           1 module
122
                                                        NOTE:   White device        Tech device                       Anthracite device                       Neutral item
1-FUNCTION SILK-SCREEN PRINTED KEY COVERS
NOTE (*): key covers also suitable for use with Sound System devices
124
                                                      NOTE:          White device                 Tech device            Anthracite device          Neutral item
CUSTOMISABLE LIVINGLIGHT KEY COVERS WITH DIFFUSERS, AVAILABLE IN KIT
                                CUSTOMISABLE KEY COVERS               1 FUNCTION         2 FUNCTIONS
                                1 module                2 modules
Description                     Item                     Item
1 FUNCTION CUSTOMISABLE         N4915TN                  N4915M2TN
KEY COVER WITH 1 DIFFUSER*      NT4915TN                 NT4915M2TN
                                L4915TN                  L4915M2TN
                                                                      Customisable       Customisable
2 FUNCTION CUSTOMISABLE         N4911TN                  N4911M2TN    with 1 diffuser    with 2 diffusers
KEY COVER WITH 2 DIFFUSERS*     NT4911TN                 NT4911M2TN
                                L4911TN                  L4911M2TN
                                DIFFUSER KIT
Description                     Item
KIT WITH DIFFUSER ON THE SIDE   N4915SETBL
(50 DIFFUSERS)
                                NT4915SETBL
                                L4915SETBL
                           3750          3823
                           3751
126
MyHOME FLATWALL
FINISHES
                                  Item         PANELS
                                   3794N       front cover panel h 120 cm for 1 device with 506E modularity
                                   3795N       front cover panel h 120 cm for 2 devices with 506E modularity
                                   3796N       front cover panel h 120 cm for 3 devices with 506E modularity
                                   3791N       front cover panel h 30 cm for 1 device with 506E modularity
                                   3792N       front cover panel h 30 cm for 2 devices with 506E modularity
                                   3793N       front cover panel h 30 cm for 3 devices with 506E modularity
                                   3797*       DIN switchboard h 30 cm - glass
                                   3798*       DIN switchboard h 30 cm - metal sheet
                                   3829        Multimedia box panel h 30 cm
                                   3799*       DIN switchboard h 30 cm - plastic
                                   3757        front cover panel h 30 cm
3794N      3795N   3796N
                                   3759        front cover panel h 60 cm
                                   3785        front cover panel h 90 cm
                                   3786        front cover panel h 120 cm
                                   3771        upper and lower finishing end caps for 240 and 270 version
                                   3825        upper and lower finishing end caps for 150 version
3791N      3792N   3793N           3761**      front cover panel for non-modular central units
                                   3769        front cover panel h 60 cm for burglar alarm
                                   * Provide some white blanking modules F215FP, to close any internal
                                   empty compartments
                                   ** Provide some white blanking modules 16133, to close any empty
                                   compartments
3797       3798    3799
           3829
3757
3759
                   3785
 3825              3786
3771 3761
                                                                                                                       3802
                                                                                                                       Mounting bracket
                                                                                                                       3 devices
                              3787
                              Device holder support
                              h 30 cm max 36 DIN mod.                                                                  3801
                                                                                                                       Mounting bracket
                                                                                                                       1 or 2 devices
                                                                            3756
                                                                            Horizontal partition
                                                                            (optional)
                              3789
                              Device holder support
                              h 60 cm max 72 DIN mod.
                                                                                                                       Power supplies and other devices
                                                                                                                       MyHOME DIN module
                              3788                        3790
                              Device holder support for   Pair of kits with
                              free fastening of non-DIN   trunking and DIN rails
                              devices                     for 3788 (optional)
                                                                                            3828
                                                                                            Multimedia equipment box
                                                                                            F496/MF
                                                                                            Clips
      3750
      Flush mounted bottom
      3751                    3787
                                                                                            3805
      Flush mounted bottom    Device holder support
                                                                                            Support bracket            3550                 3486
      for plasterboard        h 30 cm max 36 DIN mod.
                                                                                            for non-modular            Temperature          GSM burglar-alarm
      (without masonry net)                                                                 central units              control central unit central unit
128
FINISHINGS: PANELS FOR DEVICES WITH 506E MODULARITY, END CAPS AND FRAMES***                                                                     SIDE FRAME
                                                                                                                                                 FINISHING
                                                                                                                          3817N
                                                                                                                          Frames for
                                                                                                                          AXOLUTE items
                                                                                                                          3818N
                                                                                                                          Frames for
                                                                                                                          LIVING items
                                                                                                                                    3802
                                                                                                                                    Mounting bracket
                                                                                                                                    for 3 devices
                                                                                                                                    3801
                                                                                                                                    Mounting bracket
                                                                                                                                    for 1 or 2 devices
                             3787
                             Device holder support
                             h 30 cm max 36 DIN mod.
                                                                           3756
                                                                           horizontal partition
                                                                           (optional)
      3823
      Flush mounted bottom
                             3788                        3790
                             Device holder support for   Pair of kits with trunking
                             free fastening of non-DIN   and DIN rails for 3788
                             devices                     (optional)
                                                                                                  3828
                                                                                                  Multimedia equipment box
                                                                                                  F496/MF
                                                                                                  Clips
130
FINISHINGS: PANELS FOR DEVICES WITH 506E MODULARITY, END CAPS AND FRAMES***                                                 SIDE FRAME
                                                                                                                             FINISHING
    3817N                        3818N
    Frames for                   Frames for
    AXOLUTE items                LIVING items
      BASIC SETUP:            DEVICE HOLDER                     SUPPORTS                        DEVICES  FINISHINGS: PANELS, END SIDE FRAME
        BOTTOM                SUPPORTS AND                     FOR MYHOME                     THAT CAN BE CAPS AND FRAMES***      FINISHING
                               ACCESSORIES                       DEVICES                       INSTALLED
                                                                                                                       3759
                              3803                                                                                     Front cover panel h 60 cm
                              Extension module
                              (indispensable use in
                              the riser solution)
                              3787
                              Device holder support
                              h 30 cm max 36 DIN mod.
                                                                                                                       3785
                                                               3756                                                    Front cover panel h 90 cm
                                                               horizontal partition                 Power supplies
                                                               (optional)                           and other
                                                                                                    MyHome devices -
                                                                                                    DIN module
                              3789
                              Device holder support
                              h 60 cm max 72 DIN mod.
                                                                                                                       3786
                                                                                                                       Front cover panel h 120 cm
                                                                                                                                                            3821
                                                                                                                                                            3822
                                                                                                                                                            Side finishing
                                                                                                                                                            frames h 270 cm
                              3788                             3790                                                                                         and h 240 cm
                              Device holder support for free   Pair of kits with trunking and DIN
                              fastening of non-DIN devices     rails for 3778 (optional)                               3771
      3750                                                                                                             Upper and lower finishing
      Flush mounted bottom                                                                                             end caps (to be fitted last)
      3751
      Flush mounted bottom                                                                                             *** Panels and end cap must
      for plasterboard                                                                                                 always be installed after the side
      (without masonry net)                                                                                            finishing frames (3821 or 3822).
132
ASSEMBLY GUIDE:
MyHOME FLATWALL 150 AS ELECTRIC PANEL
   BASIC SETUP:        DEVICE HOLDER                SUPPORTS   DEVICES THAT CAN                              FINISHINGS:                       SIDE FRAME
     BOTTOM            SUPPORTS AND                FOR MY HOME   BE INSTALLED                              PANELS, END CAPS                     FINISHING
                        ACCESSORIES                  DEVICES                                                AND FRAMES***
                       3787
                       Device holder support h
                       30 cm max 36 DIN mod.
                                                     3756
                                                     Horizontal partition               Power supplies and   3759
                                                     (optional)                         other MyHome devices Front cover panel h 60 cm
                                                                                        - DIN module
                       3789
                       Device holder support h
                       60 cm max 72 DIN mod.
                                                                                                              3785
                                                                                                              Front cover panel h 90 cm
3823
Flush mounted bottom
                                                                                                                                                3826
                                                                                                               3825                             side finishing
                                                                                                               Upper and lower finishing        frames h 150 cm
                                                                                                               end caps (to be fitted before
                       3788                        3790                                                        front cover panels)
                       Device holder support for   Pair of kits with trunking and DIN
                                                                                                              *** Panels and end cap must
                       free fastening of non-DIN   rails for 3778 (optional)
                                                                                                              always be installed after the
                       devices
                                                                                                              side finishing frames (3821
                                                                                                              or 3822).
      BASIC SETUP:                BRACKETS AND ACCESSORIES                                      FINISHINGS: PANELS AND                                SIDE FRAME
      BOTTOM                                                                                         END CAPS ***                                      FINISHING
                                                                                            3759
                                                                                            Front cover plate
                              3803
                                                                                            h 60 cm
                              Extension module
                              (indispensable use in
                              the riser solution)
                                                                                                                                                        3821
                                                                                                                                                        3822
                                                                                                                                                        Side finishing frames
                                                                                                                                                        h 270 cm
                                                                                                                                                        and h 240 cm
      3750
      Flush mounted bottom
                                                                                    Floor
                                                                                    slab                                Extension
      3751
                                                                                                                        module
      Flush mounted bottom
      for plasterboard
      (without masonry net)             3803
                                        Example of installation of the extension module
134
COMPOSITION EXAMPLE
Composition with switchboard for protective devices h 270 cm.
63 cm
                           56 cm                            58 cm
                                                                                                                        63 cm
                                                                                                                        56 cm                            58 cm
                                        267.5 cm
267.5 cm
                                                                                                                                                                  237.5 cm
                                                                                                                                     237.5 cm
                                                                                     165 cm
       3 cm*
3 cm*
* Bottom part embedded in the floor only corresponding to the 3750 (not for 3751).
8.5 cm
                                                         58 cm
                Maximum protrusion from the wall: 2 cm
                                                                                                                                                          58 cm
                                       153 cm
60 cm
136
PANELS, SWITCHBOARDS, FINISHING END CAPS AND EXTENSION MODULE (PASSING BETWEEN FLOORS)
                                                                                                                                                                                                        7 cm
                            30 cm
                                                                              30 cm
                                                                                                                                                                          14.5 cm   14.5 cm   14.5 cm
53.3 cm 53.3 cm
                                                                                                                                               120 cm
                            30 cm
30 cm
                                                                                                                                                                                                         54.5 cm
          3757                                              3761
53.3 cm 53.3 cm
                                                                                                                         53.3 cm                                                    53.3 cm
                             30 cm
60 cm
3829
3759 90 cm
                                                                                                                                                                                                        120 cm
          58 cm                                                                           4 cm ± 1 cm
                                                                                          adjustable
                                                                                          25 cm ± 1 cm
                           2 cm
           3825                                                                           adjustable
                                                                                                                          3785
                                                            53.3 cm
                                                             3771
                                                                                                                                                                                    3786
DEVICE HOLDER SUPPORTS
Max 72 DIN modules divided on 4 rows of 18 - Max 36 DIN modules divided on 2 rows of 18.
               54 cm
                                                                      54 cm
                                     59 cm
                                                                                                                                   38 cm
                                                                                                29 cm
12 cm
                                                                37.8 cm                                         32 cm                                      7 cm
              25 cm
                                     15 cm
30 cm
                                                                                                                                                        23.5 cm
                                             29 cm
              18 cm                                                3828
                            3788
                                                                                                  Useful space for installing multimedia devices
              28 cm
      * 	 If the device is installed on the output of the F422 interface, the minimum batch is 15W25
      **	 If the device is installed on the output of the F422 interface, it is not possible to associate it using the APP.
      	 It is recommended to replace it with the code F411U2
138
For the updated list of devices see the technical sheet of the gateway device item
MyHOMEServer1.
      NOTE 1: in the case of systems with 99-zone temperature control unit, the device configuration must be made by means of physical or virtual
      configuration. In this case, all the batches are compatible.
NOTA 2: for any updates of this table, see the Gateway MyHOMEServer1 technical sheet in the Catalogue section of the bticino.com site
140
MyHOME_Up
            HOME AUTOMATION
               EVOLUTION
                                                                                                                                                                          BTicino SpA
                                                                                                                                                                          Viale Borri, 231
                                                                                                                                                                          www.bticino.com
                                                                                                                                                                          21100 Varese - Italy
                       BTicino SpA reserves at any time the right to modify the contents of this booklet
                                                                                                           AD-ITMH20GT/GB - Version 01/2020
                      and to communicate, in any form and modality, the changes brought to the same.