SERVICE BULLETIN                                                           N°   139-468
                                                                           DATE:         May 15, 2017
                                                                           REV. :        / - March 3, 2017
  TITLE
   ATA 26 - LEFT AND RIGHT FIRE DETECTION SYSTEM
  REVISION LOG
   New Issue
               An appropriate entry should be made in the aircraft log book upon accomplishment.
               If ownership of aircraft has changed, please,             forward to new owner.
                                                                                                           Page 1 of 14
 1. PLANNING INFORMATION
    A. EFFECTIVITY
       All AB139/AW139 helicopters from S/N 31005 to S/N 31157 (except S/N 31007), from
       S/N 31201 to S/N 31398 and from S/N 41201 to S/N 41293 (except S/N 41237)
       equipped with firewalls reinforcements P/N 3G7106P07351 and 3G7106P07451 or
       P/N 3P7119A35152 and 3P7119A35252 (refer to figures 1 thru 3).
    B. COMPLIANCE
       Part I
       Within one hundred (100) FH or one (1) month from receipt of this Service Bulletin,
       whichever comes first, and then every twenty-five (25) FH until part II is applied.
       Part II
        • Immediately after accomplishment of part I, if damages on sensing element beyond
           acceptable limits are found during the accomplishment of part I of this Service
           Bulletin.
        • Within one hundred (100) FH or one (1) month, whichever comes first, after first
           accomplishment of part I, if either interference without damages between firewall
           reinforcements and sensing element is detected or an acceptable damage on
           sensing element is found during the accomplishment of part I of this Service Bulletin.
        • Within fifteen hundred (1500) FH or at first engine removal, whichever comes first,
           after first accomplishment of part I, if interference is not detected and damages on
           sensing element are not found during the accomplishment of part I of this Service
           Bulletin.
    C. CONCURRENT REQUIREMENTS
       N.A.
    D. REASON
       This Service Bulletin is issued to provide the necessary instructions to modify fire
       detection sensing element installation, thus preventing possible interference with the
       firewall reinforcements.
                                                                                   S.B. N°139-468
                                                                                DATE: May 15, 2017
Page 2 of 14                                                                           REVISION: /
      E. DESCRIPTION
         Following some events of chafing between the engine fire detection system sensing
         element and the reinforcements introduced by firewalls retro modification P/N
         3G7106P06011 or repair drawing P/N 3G0203P00311, this Service Bulletin provides
         the instructions to ensure the appropriate clearance between the parts.
         In particular, part I of this Service Bulletin prescribes a visual inspection of the affected
         area that has to be repeated every twenty-five FH, in case interference between
         firewall reinforcements and sensing element is found, until accomplishment of part II.
         Part II provides instructions to implement an improved design (fire detection LH and
         RH retromod P/N 3G2610P00211), installing a new bracket between sensing element
         and firewall reinforcement, in order to increase clearance and to prevent any possible
         interference issue.
      F. APPROVAL
         The technical content of this Service Bulletin is approved under the authority of DOA
         nr. EASA.21.J.005. For helicopters registered under other Aviation Authorities, before
         applying the Service Bulletin, applicable Aviation Authority approval must be checked
         within Leonardo Helicopters customer portal.
         E.A.S.A. states mandatory compliance with inspections, modifications or technical
         directives and related time of compliance by means of relevant Airworthiness
         Directives.
         If an aircraft listed in the effectivity embodies a modification or repair not LHD certified
         and affecting the content of this Service Bulletin, it is responsibility of the
         Owner/Operator to obtain a formal approval by Aviation Authority having jurisdiction on
         the aircraft, for any adaptation necessary before incorporation of the present Service
         Bulletin.
      G. MANPOWER
         To comply with this Service Bulletin the following MMH are deemed necessary:
         Part I: approximately one (1) MMH;
         Part II: approximately ten (10) MMH.
         MMH are based on hands-on time and can change with personnel and facilities
         available
S.B. N°139-468
DATE: May 15, 2017
REVISION: /                                                                              Page 3 of 14
    H. WEIGHT AND BALANCE
       N.A.
    I. REFERENCES
       1) PUBLICATIONS
          DATA MODULE                            DESCRIPTION                       PART
          DM01    39-A-00-20-00-00A-120A-A       Helicopter on ground for a safe   I, II
                                                 maintenance
          DM02    39-A-06-41-00-00A-010A-A       Access doors and panels           I, II
          DM03    39-A-26-11-01-00A-520A-A (LH) Sensing element – Remove           I
                                           procedure
          DM04    39-A-26-12-01-00A-520A-A (RH) Sensing element – Remove           I
                                           procedure
          DM05    39-A-26-11-01-00A-720A-A (LH) Sensing element - Install          I
                                           procedure
          DM06    39-A-26-12-01-00A-720A-A (RH) Sensing element - Install          I
                                           procedure
          DM07    39-A-24-31-01-00A-520A-A Number 1 starter generator -            II
                                           Remove procedure
          DM08    39-A-24-31-01-00A-720A-A Number 1 starter generator -            II
                                           Install procedure
          DM09    39-A-24-31-02-00A-520A-A Number 2 starter generator-
                                           Remove procedure
          DM10    39-A-24-31-02-00A-720A-A Number 2 starter generator -            II
                                           Install procedure
          DM11    39-A-GG-01-00-00A-066A-A Platform (GG-01-00)                     I, II
          DM12    39-A-GG-02-00-00A-066A-A Platform (GG-02-00)                     I, II
         Refer also to the engine maintenance manual for the procedures referenced in the
         accomplishment instructions.
       2) ACRONYMS
          AMDI      Aircraft Material Data Information
          AMP       Aircraft Maintenance Publication
          ASRP      Aircraft Structural Repair Publication
          DM        Data Module
          FH        Flight Hours
          FMM       Fuel Management Module
          IPD       Illustrated Parts Data
          ITEP      Illustrated Tools & Equipment Publication
                                                                               S.B. N°139-468
                                                                            DATE: May 15, 2017
Page 4 of 14                                                                       REVISION: /
           MMH       Maintenance Man-Hours
           MMIR      Maintenance Malfunction Information Report
         3) ANNEX
           N.A.
      J. PUBLICATIONS AFFECTED
         AW139 AMP
         AW139 IPD
      K. SOFTWARE ACCOMPLISHMENT SUMMARY
         N.A.
S.B. N°139-468
DATE: May 15, 2017
REVISION: /                                                       Page 5 of 14
 2. MATERIAL INFORMATION
    A. REQUIRED MATERIALS
       1) PARTS
       PART II
       P/N                          DESCRIPTION                          Q.TY      NOTE
       3G2610P00211                 FIRE DETECTION LH AND RH             REF
                                    RETROMOD
        Composed of
       3G2610A00551                 LH sensing element bracket           1
       3G2610A00651                 RH sensing element bracket           1
       NSA5592-01                   Sensor bushing                       2
       7C31-1AA                     Clamp, loop                          2         (1)
       MS20615-4M3R                 Rivet                                4         Local
                                                                                   supply
       NAS9307M-4-01                Rivet                                4         Local
                                                                                   supply
       2) CONSUMABLES
       Refer to AMDI for the consumable materials required to comply with the AMP DM
       referenced in the accomplishment instructions.
    B. SPECIAL TOOLS
       P/N                       DESCRIPTION                      Q.TY   NOTE            PART
       RMGE-DS-06-2010-LH        Platform (GG-01-00)              AR                     I, II
       or
       2004-5007-A
       or equivalent
       RMGE-SL-06-2010           Platform (GG-02-00)              AR                     I, II
       or
       2004-5007-A
       or equivalent
       Commercial                Depth gauge                      1      (2)             I
       Refer also to ITEP for the special tools required to comply with the AMP DM
       referenced in the accomplishment instructions.
       NOTE
       (1) P/N 30-024-1 may be supplied as a valid alternative.
       (2) The Depth Gauge dial indicator must have a graduation of 0.01 mm.
                                                                                  S.B. N°139-468
                                                                               DATE: May 15, 2017
Page 6 of 14                                                                          REVISION: /
      C. INDUSTRY SUPPORT INFORMATION
         Owners/Operators who comply with the instructions of this Service Bulletin no later
         than the applicable date in the “Compliance” section will be eligible to receive
         REQUIRED MATERIALS on free of charge basis, except for Consumable Materials
         and Special Tools.
         NOTE: Customers who fail to comply with the instructions in this Service Bulletin
                before the compliance date are not eligible for the aforementioned special
                policy.
         Please Issue relevant MMIR form to your Warranty Administration Dpt.
         NOTE: INSPECTION REPORTS are mandatory; in case the MMIR is not
                accompanied by these documents, it will be rejected.
S.B. N°139-468
DATE: May 15, 2017
REVISION: /                                                                      Page 7 of 14
 3. ACCOMPLISHMENT INSTRUCTIONS
                                               GENERAL NOTES
                         a) Place an identification tag on all components that
                             are re-usable, including the attaching hardware that
                             has been removed to gain access to the
                             modification area and adequately protect them until
                             their later re-use.
                         b) Exercise extreme care during drilling operations to
                             prevent instruments, cables and hoses damage.
                         c) After drilling, remove all swarf and sharp edges.
                             Apply on bare metal a light film of primer unless the
                             hole is used for ground connection.
                         d) Lenghts in the figures are in mm.
 PART I
 1.   In accordance with DM 39-A-00-20-00-00A-120A-A, prepare the helicopter on ground for
      a safe maintenance. Disconnect the battery, all electrical power sources and/or the
      external power supply.
 2.   Prepare access to the inspection area on the left side as follows:
      2.1      Put the Platform (GG-01-00), or an approved alternative, adjacent to the left side
               of the fuselage.
      2.2      Open the access door (461AL). Refer to AMP, see DM 39-A-06-41-00-00A-010A-
               A.
 3.   Prepare access to the inspection area on the right side as follows:
      3.1      Put the Platform (GG-02-00), or an approved alternative, adjacent to the right
               side of the fuselage.
      3.2      Open the access door (462AR). Refer to AMP, see DM 39-A-06-41-00-00A-
               010A-A.
 4.   With reference to figure 1, perform a visual inspection of the fire detection system
      sensing element for possible interference with the firewall reinforcements and damage.
      4.1      In case of no findings or if a scratch is found on the sensing element with a depth
               of 0.1 mm or lower, go to step 5.
      4.2      If a scratch is found on the sensing element with a depth higher than 0.1 mm,
               perform following steps:
               4.2.1     Remove the damaged sensing element. Refer to AMP, see DM 39-A-
                         26-11-01-00A-520A-A and/or DM 39-A-26-12-01-00A-520A-A.
                                                                                    S.B. N°139-468
                                                                                 DATE: May 15, 2017
Page 8 of 14                                                                            REVISION: /
               4.2.2     Perform immediately fire detection retromod P/N 3G2610P00211
                         according to part II of this Service Bulletin.
               4.2.3     Install a new sensing element. Refer to AMP, see DM 39-A-26-11-01-
                         00A-720A-A and/or DM 39-A-26-12-01-00A-720A-A.
   5.   Close the access doors (461AL) and (462AR). Refer to AMP, see DM 39-A-06-41-00-
        00A-010A-A.
   6.   Remove the platforms from both sides of the fuselage.
   7.   Return the helicopter to flight configuration and record for compliance with part I of this
        Service Bulletin on the helicopter logbook.
S.B. N°139-468
DATE: May 15, 2017
REVISION: /                                                                            Page 9 of 14
 PART II
 1.   In accordance with DM 39-A-00-20-00-00A-120A-A, prepare the helicopter on ground for
      a safe maintenance. Disconnect the battery, all electrical power sources and/or the
      external power supply.
 2.   Prepare access to the work area on the left side as follows:
      2.1    Put the Platform (GG-01-00), or an approved alternative, adjacent to the left side
             of the fuselage.
      2.2    Open the access door (461AL). Refer to AMP, see DM 39-A-06-41-00-00A-010A-
             A.
 3.   With reference to figure 2, perform fire detection retromod P/N 3G2610P00211 on the
      LH side as follows:
      3.1    Remove the Number 1 starter generator according to AMP DM 39-A-24-31-01-
             00A-520A-A.
      3.2    Remove the FMM according to the engine maintenance manual (see chapter
             73.20.03, paragraph 5.A).
      3.3    Install   clamp    P/N    7C31-1AA   on   new   sensing   element    bracket   P/N
             3G2610A00551 using two rivets P/N MS20615-4M3R.
                                              CAUTION
                        Make sure that there is clearance between the firewall
                        reinforcement and the sensing element new routing
                        when positioning the bracket, according to figure 2
                        section C-C.
                                                  NOTE
                        It is allowed to temporarily disconnect the sensing
                        element from clamps near the firewall reinforcement, if
                        required to have an easier access to the work area.
      3.4    Install the sensing element bracket P/N 3G2610A00551 on the firewall
             reinforcement using two rivets P/N NAS9307M-4-01.
      3.5    Fix the sensing element with sensor bushing P/N NSA5592-01 on the clamp in
             the new position.
      3.6    Install the FMM according to the engine maintenance manual (see chapter
             73.20.03, paragraph 5.B).
      3.7    Install the Number 1 starter generator according to AMP DM 39-A-24-31-01-00A-
             720A-A.
 4.   Prepare access to the work area on the right side as follows:
      4.1    Put the Platform (GG-02-00), or an approved alternative, adjacent to the right
                                                                                 S.B. N°139-468
                                                                              DATE: May 15, 2017
Page 10 of 14                                                                        REVISION: /
               side of the fuselage.
        4.2    Open the access door (462AR). Refer to AMP, see DM 39-A-06-41-00-00A-
               010A-A.
   5.   With reference to figure 3, perform fire detection retromod P/N 3G2610P00211 on the
        RH side as follows:
        5.1    Remove the Number 2 starter generator according to AMP DM 39-A-24-31-02-
               00A-520A-A.
        5.2    Install   clamp    P/N    7C31-1AA     on   new   sensing   element   bracket    P/N
               3G2610A00651 using two rivets P/N MS20615-4M3R.
                                                 CAUTION
                          Make sure that there is clearance between the firewall
                          reinforcement and the sensing element new routing
                          when positioning the bracket, according to figure 3
                          section D-D.
                                                    NOTE
                          It is allowed to temporarily disconnect the sensing
                          element from clamps near the firewall reinforcement, if
                          required to have an easier access to the work area.
        5.3    Install the sensing element bracket P/N 3G2610A00651 on the firewall
               reinforcement using two rivets P/N NAS9307M-4-01.
        5.4    Fix the sensing element with sensor bushing P/N NSA5592-01 on the clamp in
               the new position.
        5.5    Install the Number 2 starter generator according to AMP DM 39-A-24-31-02-00A-
               720A-A.
   6.   Close access doors (461AL) and (462AR). Refer to AMP, see DM 39-A-06-41-00-00A-
        010A-A.
   7.   Remove the platforms from both sides of the fuselage.
   8.   Return the helicopter to flight configuration and record for compliance with part II of this
        Service Bulletin on the helicopter logbook.
   9.   Send the attached compliance form to the following mail box:
                                 cse.aw139.aw@leonardocompany.com
        As an alternative, gain access to My Communications section on Leonardo WebPortal
        and compile the “Service Bulletin Application Communication”.
S.B. N°139-468
DATE: May 15, 2017
REVISION: /                                                                           Page 11 of 14
                                      B                                                3G2610P00211
                                                                                       FIRE DETECTION
                                                                                       LH AND RH RETROMOD
                  LH
            D
         FW
                SPACE VIEW
                            3G7106P07351 OR 3P7119A35152
                            REINFORCEMENT LH (SHOWN) (REF.)
                            3G7106P07451 OR 3P7119A35252
                            REINFORCEMENT RH (OPPOSITE) (REF.)
                         WAS
                                                                            EXISTING NSA5592-01
  EXISTING NSA5592-01                                                       SENSOR BUSHING (REF)
  SENSOR BUSHING (REF)                                                      EXISTING 7C31-1AA
  EXISTING 7C31-1AA                                                         CLAMP LOOP (REF)
  CLAMP LOOP (REF)
  FIRE DETECTOR SENSOR
  OLD ROUTING
                                                           VIEW A      (TYP OPP SIDE)
                         ENGINE, STRUCTURES AND SYSTEMS ARE PARTIALLY OMITTED FOR BETTER CLARITY PURPOSE
                                                       Figure 1
                                                                                                         S.B. N°139-468
                                                                                                      DATE: May 15, 2017
Page 12 of 14                                                                                                REVISION: /
                                                                                                                    3G2610P00211
                                                     BECOMES                                                        FIRE DETECTION
                  INSTALL:
                  3G2610A00551 SENSING
                                                                                                                    LH AND RH RETROMOD
                                                                  15.00
                  ELEMENT BRACKET
                                                                                                       EXISTING NSA5592-01
                                                                   INSTALL:                            SENSOR BUSHING
         INSTALL:                                                                                      EXISTING 7C31-1AA
         NSA5592-01 SENSOR BUSHING                                  02 N
                                                                                                       CLAMP LOOP
         7C31-1AA CLAMP LOOP
                                                                                 INSTALL:
                                                                                  01 N
                                INSTALL:
                                 01 N
  EXISTING NSA5592-01
  SENSOR BUSHING
  EXISTING 7C31-1AA                                                       INSTALL:
  CLAMP LOOP                                                               02 N
                                 C                            C
                                                                                     249.4
     FIRE DETECTOR SENSOR
     NEW ROUTING
                         WL
                        2671                                               VIEW A
                                                          ENGINE, STRUCTURES AND SYSTEMS
                                                  ARE PARTIALLY OMITTED FOR BETTER CLARITY PURPOSE
                                                                                                                             FIRE DETECTOR SENSOR
                                                                                                                             NEW ROUTING
                                                                              3G7106P07351 OR 3P7119A35152
                                                                              REINFORCEMENT LH (REF.)
                                     3.5 RAN
                                     CL
                                        EA
                                                                          SECTION C-C
                                           CE
                                                                     RIVET CODE
                                                       N: Head is on Near side
                                           REF. NUMBER F: Head is on Far side                REF. N.    RIVET P/N
                                         :COUNTERSINK                                            01     MS20615-4M3R
                                          (100˚ only) is on                                      02     NAS9307M-4-01
                                          Near side
                                         :COUNTERSINK
                                          (100˚ only) is on
                                          Far side
                                                                      Figure 2
S.B. N°139-468
DATE: May 15, 2017
REVISION: /                                                                                                                              Page 13 of 14
                                                                                                        3G2610P00211
                          INSTALL:
                                                             BECOMES                                    FIRE DETECTION
                            01 N
                                                                                                        LH AND RH RETROMOD
                                                                            15.00
                                                                                           INSTALL:
             EXISTING NSA5592-01                                                           3G2610A00651 SENSING
             SENSOR BUSHING                               INSTALL:
                                                                                           ELEMENT BRACKET
             EXISTING 7C31-1AA                              02 N
             CLAMP LOOP
                                                                                                        INSTALL:
                                                                                                        NSA5592-01 SENSOR BUSHING
                                                                                                        7C31-1AA CLAMP LOOP
                                                                                                  INSTALL:
                                                                                                    01 N
                                                                                                                    EXISTING NSA5592-01
                                                                                                                    SENSOR BUSHING
                                                                                                                    EXISTING 7C31-1AA
                                                                                                                    CLAMP LOOP
                                                            D                D
                                                          INSTALL:
                                                            02 N
                                            249.4
                                                                                                                      FIRE DETECTOR SENSOR
                                                                                                                      NEW ROUTING
                                                                VIEW B                                                               WL
                                                                                                                                    2671
                                               ENGINE, STRUCTURES AND SYSTEMS
                                       ARE PARTIALLY OMITTED FOR BETTER CLARITY PURPOSE
        FIRE DETECTOR SENSOR
        NEW ROUTING
                           3G7106P07451 OR 3P7119A35252
                                                                                              E
                                                                                            NC
                           REINFORCEMENT RH (REF.)
                                                                                       EA 3.5
                                                                                         RA
                                                                                      CL
                                                          SECTION D-D
                                                                 RIVET CODE
                                                  N: Head is on Near side
                                      REF. NUMBER F: Head is on Far side            REF. N.      RIVET P/N
                                     :COUNTERSINK                                       01       MS20615-4M3R
                                      (100˚ only) is on                                 02       NAS9307M-4-01
                                      Near side
                                     :COUNTERSINK
                                      (100˚ only) is on
                                      Far side
                                                                Figure 3
                                                                                                                          S.B. N°139-468
                                                                                                                       DATE: May 15, 2017
Page 14 of 14                                                                                                                 REVISION: /
 Please send to the following address:
                                                                 SERVICE BULLETIN COMPLIANCE FORM                                          Date:
LEONARDO S.p.A.
CUSTOMER SUPPORT & SERVICES - ITALY                            Number:
PRODUCT SUPPORT ENGINEERING & LICENSES DEPT.
Via Giovanni Agusta, 520
21017 Cascina Costa di Samarate (VA) - ITALY                   Revision:
Tel.: +39 0331 225036 Fax: +39 0331 225988
Customer Name and Address:                                                                   Telephone:
                                                                                             Fax:
                                                                                             B.T. Compliance Date:
     Helicopter Model                              S/N                            Total Number                       Total Hours                       T.S.O.
Remarks:
Information:
We request your cooperation in filling this form, in order to keep out statistical data relevant to aircraft configuration up-to-date. The form should be filled in all
its parts and sent to the above address or you can communicate the application also via Technical Bulletin Application Communication Section placed in
Leonardo AW Customer Portal - MyCommunications Area. We thank you beforehand for the information given.