ATCC TEST LABS ULR No.

:
TL110424000000297

DOC No. : ATCC/24021003 KHASRA NO. 45/6, SITUATED IN THE AREA, VILLAGE
Telephone : +91 9891606632 PRAHLADPUR BANGER,, North West Delhi, Delhi,
FAX : - 110042, Delhi, North West, Delhi, India - 110042
E-Mail : info@atncc.in
BO Code : NA

Test REPORT AS PER : IS 13252 : Part 1 (2010)

QR Code/Barcode : 180964CRS

REPORT NO : SC24EPF02900_2 DATE : 26 Apr, 2024

PART A. PARTICULARS OF SAMPLE SUBMITTED

a) Customer Name & Address : KINGPLUS INC


NO.2 WEST BUILDING, CHANG XINGGAO XIN
TECHNICAL INDUSTRIAL PARK, WAN-AN ROAD,
SHA-YI VILLAGE, SHA-JING LANE, BAO AN AREA,
SHENZHEN CITY, GUANGDONG CHINA, NA,
SHENZHEN, China - 000000
b) Nature of sample : -
c) Grade/Variety/Type/Class Size etc : NA
d) Declare values, if any : -
e) Batch No. & Date of Manufacture : /
f) Quantity : 1
g) Date of Receipt : 10 Feb, 2024
h) BIS Seal : Verified by Sample Cell
i) IO's Signature : Verified by Sample Cell
j) Any other Information / Expiry Date, If any : /
k) Date of Commencement of Testing : 13 Feb, 2024
l) Date of Completion of Testing : 26 Mar, 2024
m) Section Code : 24EBCA3N
n) Section Report No. : 24EBCA3N_1_A1
o) Report Type : Revised
p) Reference Report No. : SC24EPF02900_1
q) Remarks :

Rajiv Jadon
OIC SAMPLE CELL
(Authorized Signatory)
Authorized on: 26 Apr, 2024 16:30 PM

1.

This is a Computer Generated Report.

Page 1 of 110
Section Report No. : 24EBCA3N_1_A1 IS 13252 : Part 1 (2010)

PART B. SUPPLEMENTARY INFORMATION

1. Reference to sampling procedure, wherever applicable. Not Applicable


2. Supporting documents for the measurements taken and results derived like graphs, Yes
table sketches and or photographs as appropriate to test report, if any.
3. Deviation from the test methods as prescribed in relevant ISS/Work instruction, if any. Not Applicable
3. NABL Report required ? -

Ravi Kumar Kushwaha


OIC Electrical
(Authorized Signatory)
Authorized on: 26 Apr, 2024 16:29 PM

This is a Computer Generated Report.

Page 2 of 110
Section Report No. : 24EBCA3N_1_A1 IS 13252 : Part 1 (2010)

PART C. TEST RESULT

S.No. Clause No Parameter - Test Description Min Max Unit Result/


Table No. Method of test Limit Limit Observation
Sl. No

1 4.6.2 Bottoms of fire - - - - Test Not Applicable


enclosures

2 Annex EE Household and - - - - Test Not Applicable


home/ office
document/ media
shredders

3 Annex DD Requirements for the - - - - Test Not Applicable


mounting means of a
rack mounted
equipment

4 Annex C Transformers - - - - Test Not Applicable

5 Annex B Motor tests under - - - - Test Not Applicable


abnormal conditions

6 Annex Q Voltage Dependent - - - - Test Not Applicable


Resistors

7 Annex K Thermal Control - - - - Test Not Applicable

8 3.1.4 Internal wire - - - - Test Not Applicable

9 2.10.12 Enclosed and sealed - - - - Test Not Applicable


parts

10 2.10.11 Tests for - - - - Test Not Applicable


semiconductor
devices and for
cemented joints

11 2.10.10 Test for Pollution - - - - Test Not Applicable


Degree 1
environment and for
insulating compound

12 2.10.9 Thermal Cycling - - - - Test Not Applicable

13 2.10.8.4 Abrasion resistance - - - - Test Not Applicable


test

14 2.10.8.2 Thermal conditioning - - - - Test Not Applicable


(thermal ageing)

15 2.10.6 PCB material - - - - Test Not Applicable

16 2.10.5.6 Thin sheet materials - - - - Test Not Applicable

17 2.10.5.3 Insulating Compound - - - - Test Not Applicable


as Solid Insulation

18 2.10.4.2 Material Group and - - - - Test Not Applicable


Comparative
Tracking Index

19 2.8.2/2.8.5 Interlock switches - - - - Test Not Applicable

20 7.4 Insulation between Insulation between - - - Test Not Applicable


primary circuits and primary circuits and
cable distribution cable distribution
systems systems

21 7.3 Protection of Protection of - - - Test Not Applicable


equipment users equipment users
from overvoltages on from overvoltages on
the cable distribution the cable distribution
system system

Page 3 of 110
22 7.2 Protection of cable Protection of cable - - - Test Not Applicable
distribution system distribution system
service persons, and service persons, and
users of other users of other
equipment equipment
connected to the connected to the
system, from system, from
hazardous voltages hazardous voltages
in the equipment in the equipment

23 7.1 General Connection to cable - - - Test Not Applicable


distribution systems

24 6.3 Protection of the Protection of the - - - Test Not Applicable


telecommunication telecommunication
wiring system from wiring system from
overheating overheating

25 6.2 Protection of Protection of - - - Test Not Applicable


equipment users equipment users
from overvoltages on from overvoltages on
networks networks
telecommunication telecommunication

26 6.1 Protection of Protection of - - - Test Not Applicable


telecommunication telecommunication
network service network service
persons, and users of persons, and users of
other equipment other equipment
connected to the connected to the
network, from network, from
hazards in the hazards in the
equipment equipment

27 5.3 Abnormal operating Abnormal operating - - - Compliance (For


and fault conditions and fault conditions more describe result
test see final report)

28 5.2 Electric strength To Check Insulation - - - Test Not Applicable


as per Clause
5.2,5.2.1,5.2.2

29 5.1 Touch current and Cl. 5.1 - - - Test Not Applicable


protective conductor
curren

30 4.7 Resistance to fire Clause 4.7, 4.7.1, - - - Compliance (For


4.7.2, 4.7.2.1, more describe result
4.7.2.2, 4.7.3, 4.7.3.1 see final report)

31 4.6 Openings in Openings in - - - Test Not Applicable


enclosures enclosures

32 4.5 Thermal Temperature rise - - - Compliance (For


requirements measurement Test more describe result
see final report)

33 4.4 Protection against Protection against - - - Test Not Applicable


hazardous moving hazardous moving
parts parts

34 4.3 Design and Design and - - - Compliance (For


construction construction more describe result
see final report)

35 4.2 Mechanical strength Mechanical Strength - - - Compliance (For


Test more describe result
see final report)

36 4.1 Stability Clause 4.1 Stability - - - Test Not Applicable

37 3.5 Interconnection of Clause 3.5, 3.5.1, - - - Compliance (For


equipment 3.5.2, 3.5.4 more describe result
see final report)

38 3.4 Disconnection from Appliance inlet is - - - Test Not Applicable


the mains supply considered as
disconnect device

39 3.3 Wiring terminals for Wiring terminals for - - - Test Not Applicable
connection of connection of
external conductors external conductors

40 3.2 Connection to a Clause 3.2: - - - Test Not Applicable


mains supply Connection to a
mains supply

Page 4 of 110
41 3.1 General Clause 3.0, 3.1.1, - - - Compliance (For
3.1.2, 3.1.3 more describe result
see final report)

42 2.10 Clearances, creepage Clause 2.10, - - - Compliance (For


distances and 2.10.1.2, 2.10.1.3, more describe result
distances through 2.10.3, 2.10.3.4 see final report)
insulation

43 2.9 Electrical insulation Clause 2.9 Electrical - - - Compliance (For


insulation more describe result
see final report)

44 2.8 Safety interlocks Clause 2.8 Safety - - - Test Not Applicable


Interlocks-

45 2.7 Overcurrent and Certified Fuse is - - - Test Not Applicable


earth fault protection provided for
in primary circuits protection against
short – circuits and
overcurrent. The
building installation
consider as short-
circuit backup
protection.

46 2.6 Provisions for Clause 2.6 Provisions - - - Test Not Applicable


earthing and bonding for earthing and
bonding

47 2.5 Limited power Limited power - - - Test Not Applicable


sources . sources test perform
on Secondary Li-ion
battery pack

48 2.4 Limited current Limited current - - - Test Not Applicable


circuits circuits

49 2.3 TNV circuits TNV circuits - - - Test Not Applicable

50 2.2 SELV circuits Clause 2.2: SELV - - - Compliance (For


circuits more describe result
see final report)

51 2.1 Protection from Clause 2.1: - - - Compliance (For


electric shock and Protection from more describe result
energy hazards electric shock and see final report)
energy hazards

52 1.7 Markings and Clause: 1.7.11 - - - Compliance (For


instructions (Durability) Rubbing more describe result
the marking by hand see final report)
for 15s with a piece
of cloth soaked with
water and again for
15 s with a piece of
cloth soaked with
petroleum spirit.

53 1.6 Power interface . Input current - - - Compliance (For


Measurement more describe result
see final report)

54 1.5 Components Addition of alternate - - - Compliance (For


certified switching more describe result
power supply based see final report)
on relevant
documents provided
by manufacturer

Ravi Kumar Kushwaha


OIC Electrical
(Authorized Signatory)
Authorized on: 26 Apr, 2024 16:29 PM

This is a Computer Generated Report.

Page 5 of 110
Section Report No. : 24EBCA3N_1_A1 IS 13252 : Part 1 (2010)

PART D. REMARKS

Ravi Kumar Kushwaha


OIC Electrical
(Authorized Signatory)
Authorized on: 26 Apr, 2024 16:29 PM

This is a Computer Generated Report.

Page 6 of 110
SUMMARY OF TEST REPORT

TEST REPORT NO: SC24EPF02900_1 DATE: 19/03/2024


ULR- B-TL110424000000297

(Number of Pages in Test Report: Page No. 1 to 101)

TEST FORMAT AS PERIS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / IEC 60950-1: 2005 + A1: 2009 +
A2: 2013

1. Name of the Manufacturer: KINGPLUS INC

2. Product: Scanner
3. Model: S602

4. Trade Mark:
5. Model differences provided (if applicable): N/A
6. Model differences verified as per MEITY Guidelines for series formulation: N/A
7. Test Results: Refer below
PARTA: GENERAL

SL. NO. TEST REQUIREMENT TEST CODE CLAUSE VERDICT


1. Components EL 2100 1.5 P
2. Power interface EL 2101 1.6 P
3. Markings and instructions EL 2102 1.7 P

PART B: PROTECTION FROM HAZARDS

SL. NO. TEST REQUIREMENT TEST CODE CLAUSE VERDICT


1. Protection from electric shock and energy hazards EL 2103 2.1 P
2. SELV circuits EL 2104 2.2 P
3. TNV circuits EL 2105 2.3 N/A
4. Limited current circuits EL 2106 2.4 N/A
5. Limited power source EL 2107 2.5 N/A
6. Provisions for earthing and bonding EL 2108 2.6 N/A
7. Overcurrent and earth fault protection in primary circuits EL 2109 2.7 N/A
8. Safety interlocks EL 2110 2.8 N/A
9. Electrical insulation EL 2111 2.9 P
Clearances, creepage distance and distances through P
10. EL 2112 2.10
insulation

Page 1 of 3

Page 7 of 110
TEST REPORT NO: SC24EPF02900_1 DATE: 19/03/2024
ULR- B-TL110424000000297

PART C: WIRING, CONNECTIONS AND PHYSICAL REQUIREMENTS

SL. NO TEST REQUIREMENT TEST CODE CLAUSE VERDICT


1. Wiring, connections and supply EL 2113 3 P
.
2. Connection to a mains supply EL 2114 3.2 N/A
3. Wiring terminals for connection of external conductors EL 2115 3.3 N/A
4. Disconnections from the main supply EL 2116 3.4 N/A
5. Interconnection of equipment EL 2117 3.5 P
6. Stability EL 2118 4.1 N/A
7. Mechanical strength EL 2119 4.2 P
8. Design and construction EL 2120 4.3 P
9. Protection against hazardous moving parts EL 2121 4.4 N/A
10. Thermal requirements EL 2122 4.5 P
11. Openings in enclosures EL 2123 4.6 N/A
12. Resistance to fire EL 2124 4.7 P

PART D: ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS

SL. NO. TEST REQUIREMENT TEST CODE CLAUSE VERDICT


1. Touch current and protective conductor current EL 2125 5.1 N/A
2. Electric strength EL 2126 5.2 N/A
3. Abnormal operating and fault conditions EL 2127 5.3 P
PART E: CONNECTION TO TELECOMMUNICATION NETWORK AND CABLE DISTRIBUTION SYSTEM

SL. NO. TEST REQUIREMENT TEST CODE CLAUSE VERDICT


1. Protection of telecommunication network service EL 2128 6.1 N/A
persons and users of other equipment connected to the
network, from hazards in the equipment
2. Protection of equipment users from overvoltages on EL 2129 6.2 N/A
telecommunication networks
3. Protection of the telecommunication wiring system from EL 2130 6.3 N/A
overheating
4. Connection to cable distribution systems EL 2131 7 N/A

Page 2 of 3

Page 8 of 110
TEST REPORT NO: SC24EPF02900_1 DATE: 19/03/2024
ULR- B-TL110424000000297

GENERAL INFORMATION:

1. The conformity certificates of critical components are verified to ensure complete testing of apparatus
under test and details regarding harmonized IEC standards (where IEC standards are not available)
are also provided in the list of critical components.

CONCLUSION:

1. Sample meets all relevant requirements of IS 13252 (Part 1): 2010 + A1: 2013 + A2 : 2015 / IEC
60950-1: 2005 + A1: 2009 + A2 : 2013

2. Sample fails to meet the following test requirements.

I, hereby undertake that the verdict stated in the test reports for all the test matches with the test results. The
sample meets all relevant requirements of IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / IEC 60950-1:
2005 + A1: 2009 + A2: 2013/does not meet the requirements. If any deviation found, suitable punitive action
may be taken by BIS

Date: 19/03/2024 (Signature of Authorized person with Stamp)

Page 3 of 3

Page 9 of 110
Test Report No.: SC24EPF02900_1 Page 1 of 101
ULR- B-TL110424000000297 Issue Date: 19/03/2024

Manufacturer: KINGPLUS INC


NO.2 WEST BUILDING, CHANG XINGGAO XIN TECHNICAL INDUSTRIAL
PARK, WAN-AN ROAD, SHA-YI VILLAGE, SHA-JING LANE, BAO AN AREA,
SHENZHEN CITY, GUANGDONG CHINA

Test item: Scanner

Identification: S602 Serial No.: KFG1040E1000027


Job No.: 24021003 Date of receipt: 10/02/2024
Sample Code: 24EBCA3N
Test Request No: SC24EPF02900
Testing laboratory and its ATCC TEST LABS
address: 45/6, Village Prahaladpur Bangar, Industrial Area, Rohini, Delhi 110042

IS 13252 (Part 1): 2010 + A1: 2013 + A2 : 2015 /


Test specification:
IEC 60950-1: 2005 + A1: 2009 + A2 : 2013
Test Result: The test item passed / failed the test specification.

Other Aspects: This report consists of 101 pages

This test report relates to the test sample submitted and list of documents attached.

Approved by /
Tested by: Issued by:
Authorized Signatory:

Divyanshu Ravi Prakash Kushavaha Rohit


(Testing Engineer) (Technical Manager) (Customer Officer)
Date: 19/03/2024 Date: 19/03/2024 Date: 19/03/2024

Page 10 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2 : 2015 / Page 2 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2 : 2013 ULR- B-TL110424000000297

TEST REPORT
IS 13252 (Part 1): 2010 + A1: 2013+ A2: 2015 /
IEC 60950-1: 2005 + A1: 2009 + A2: 2013
Information technology equipment – Safety –
Part 1: General requirements
“SCANNER”
Report Reference No. .................... : SC24EPF02900_1
Date of issue .................................... : 19/03/2024
Total number of pages ...................... 101
Testing Laboratory ......................... : ATCC TEST LABS
Address ............................................ : 45/6, Village Prahaladpur Bangar, Industrial Area, Rohini, Delhi
110042
Manufacturer’s name ..................... : KINGPLUS INC
Address ............................................ : NO.2 WEST BUILDING, CHANG XINGGAO XIN TECHNICAL
INDUSTRIAL PARK, WAN-AN ROAD, SHA-YI VILLAGE, SHA-JING
LANE, BAO AN AREA, SHENZHEN CITY, GUANGDONG CHINA
Test specification:
Standard ........................................... : IS 13252 (Part 1): 2010 + A1: 2013+ A2:2015 /
IEC 60950-1: 2005 + A1: 2009 +A2:2013
Test procedure ................................. : Compliance Report
Non-standard test method…………..: N/A
Test Report Form No. .................... : BIS_IT/S_IS13252_V1.4
Test Report Form(s) Originator ........ : Bureau of Indian Standards
Master TRF ...................................... : 03/06/2016
Test item description ..................... : Scanner
Trade Mark ....................................... :

Model/Type reference ...................... : S602

Ratings ............................................. : INPUT: 5V 500mA


Other Documents submitted ............ : Please refer to Table – List of Attachments at Page No.08

Approved by /
Tested by: Issued by:
Authorized Signatory:

Divyanshu Ravi Prakash Kushavaha Rohit


(Testing Engineer) (Technical Manager) (Customer Officer)
Date: 19/03/2024 Date: 19/03/2024 Date: 19/03/2024

TRF No. BIS_IT/S_IS13252_V1.4

Page 11 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 3 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Test Description Measurement/ testing Total No. Total no. of No. of Page
Code of tests applicable tests/ No.
tests/ Req. Req.
passed
EL 2100 General Components (Cl.1.5) 18 03 03 11-12
Requirements
EL 2101 General Power interface (Cl.1.6) 05 02 02 13
Requirements
EL 2102 Marking Marking & 39 16 16 14-16
Requirements instructions(Cl.1.7)
EL 2103 Electrical safety Protection from electric 14 04 04 17-18
shock and energy
hazards (Cl.2.1)
EL 2104 Electrical safety SELV Circuits (Cl.2.2) 04 04 04 19
EL 2105 Electrical safety TNV Circuits (Cl.2.3) 12 00 N/A 20
EL 2106 Electrical safety Limited current circuits 04 00 N/A 21
(Cl.2.4)
EL 2107 Electrical safety Limited Power sources 07 00 N/A 22
(Cl.2.5)
EL 2108 Electrical safety Provisions for earthing 19 00 N/A 23-24
and bonding (Cl.2.6)

EL 2109 Electrical safety Overcurrent and earth 07 00 N/A 25


fault protection in
primary circuits (Cl.2.7)
EL 2110 Electrical safety Safety Interlocks 13 00 N/A 26
(Cl.2.8)
EL 2111 Electrical safety Electrical Insulation 05 04 04 27
(Cl.2.9)
EL 2112 Electrical safety Clearances, Creepage 63 04 04 28-31
distances and distances
through insulation
(Cl.2.10)
EL 2113 Wiring Wiring, connections 11 01 01 32
and supply (Cl.3)
EL 2114 Wiring Connection to a main 14 00 N/A 33-34
supply (Cl.3.2)
EL 2115 Wiring Wiring terminals for 09 00 N/A 35
connection of external
conductors (Cl.3.3)
EL 2116 Wiring Disconnection for the 12 00 N/A 36
main supply (Cl.3.4)
EL 2117 Wiring Interconnection of 05 03 03 37
equipment (Cl.3.5)
EL 2118 Mechanical Stability (Cl.4.1) 04 00 N/A 38
properties
EL 2119 Mechanical Mechanical strength 13 05 05 39

TRF No. BIS_IT/S_IS13252_V1.4

Page 12 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 4 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

properties (Cl.4.2)
EL 2120 Mechanical Design and 25 03 03 40-41
properties construction (Cl.4.3)
EL 2121 Mechanical Protection against 14 00 N/A 42
properties hazardous moving parts
(Cl.4.4)
EL 2122 Thermal Thermal requirements 06 05 05 43
Properties (Cl.4.5)
EL 2123 Mechanical Openings in Enclosures 18 00 N/A 44-45
properties (Cl.4.6)
EL 2124 Fire Safety Resistance to fire 25 09 09 46-51
(Cl.4.7)
EL 2125 Insulating Electrical requirements 20 01 01 52-53
properties and simulated abnormal
conditions(Cl.5),5.1
EL 2126 Insulating Electric Strength 03 00 N/A 54
properties (Cl.5.2)
EL 2127 Insulating Abnormal operating and 11 05 05 55
properties fault conditions (Cl.5.3)
EL 2128 Communicating Protection of 04 00 N/A 56-57
connection telecommunication
network service
persons, and users of
other equipment
connected to the
network, from hazards
in the equipment(Cl.6.1)
EL 2129 Communicating Protection of equipment 06 00 N/A 58
connection users from overvoltages
on telecommunication
networks (Cl.6.2)
EL 2130 Communicating Protection of the 05 00 N/A 59-60
connection telecommunication
wiring system from
overheating (Cl.6.3)
EL 2131 Connection to Connection to cable 08 00 N/A 61
cable distribution distribution systems
systems (Cl.7)
EL 2132 Fire safety Tests for resistance to 20 02 02 62-63
heat and fire (Annex A)
EL 2133 Insulating Motor tests under 19 07 07 64-65
properties abnormal conditions
(Annex B)
EL 2134 Electrical Safety Transformers 03 00 N/A 66
(Annex C)
EL 2135 Insulating Measuring Instruments 03 00 N/A 67
properties For Touch-Current
Tests (Annex D)

TRF No. BIS_IT/S_IS13252_V1.4

Page 13 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 5 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

EL 2136 Thermal Temperature Rise Of A 01 00 N/A 68


Properties Winding(Annex E)
EL 2137 Electrical safety Measurement Of 01 00 N/A 69
Clearances And
Creepage
Distances(Annex F)
EL 2138 Electrical safety Alternative Method For 17 00 N/A 70-71
Determining Minimum
Clearances(Annex G)
EL 2139 Radiation Safety Ionizing 01 00 N/A 72
Radiation(Annex H)
EL 2140 Electrical Safety Table of 01 00 N/A 73
electrochemical
potentials (Annex J)
EL 2141 General Thermal controls 07 00 N/A 74
Requirements (Annex K)
EL 2142 General Normal load conditions 08 02 02 75
Requirements for some types of
electrical business
equipment (Annex L)
EL 2143 Electrical Safety Criteria for telephone 13 00 N/A 76
ringing signals
(Annex M)
EL 2144 Electrical safety Impulse Test 03 00 N/A 77
Generators(Annex N)
EL 2145 General Normative 02 00 N/A 78
Requirements References(Annex P)
EL 2146 General Voltage dependent 03 00 N/A 79
Requirements resistors (VDRs)
(Annex Q)
EL 2147 General Examples Of 03 00 N/A 80
Requirements Requirements For
Quality Control
Programmes(Annex R)
EL 2148 General Procedure For Impulse 04 00 N/A 81
Requirements Testing (Annex S)
EL 2149 Protection Guidance On Protection 01 00 N/A 82
against Ingress Against Ingress Of
of water Water (Annex T)
EL 2150 Wiring Insulated Winding 17 00 N/A 83-84
Wires For Use Without
Interleaved Insulation
(Annex U)
EL 2151 Electrical Ac Power Distribution 05 00 N/A 85
Safety Systems(Annex V)
EL 2152 Electrical Summation Of Touch 08 00 N/A 86
Safety Currents (Annex W)
EL 2153 Electrical Maximum Heating 03 00 N/A 87
TRF No. BIS_IT/S_IS13252_V1.4

Page 14 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 6 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Safety Effect In Transformer


Tests(Annex X)
EL 2154 Radiation safety Ultraviolet light 05 00 N/A 88
conditioning test
(Annex Y)
EL 2155 Electrical Overvoltage Categories 01 00 N/A 89
Safety (Annex Z)

EL 2156 Mechanical Mandrel Test(Annex 01 00 N/A 90


properties AA)

EL 2157 Electrical Changes In The -- -- -- --


Safety Second Edition(Annex
BB)

EL 2158 Electrical Safety Evaluation Of 06 00 N/A 91


Integrated Circuit (IC)
Current Limiters (Annex
CC)
EL 2159 Mechanical Requirements For The 04 00 N/A 92
properties Mounting Means Of
Rack-Mounted
Equipment (Annex DD)
EL 2160 Electrical Household And 06 00 N/A 93
Safety Home/Office
Document/Media
Shredders (Annex EE)

Certificate: It is certified that the above tests were performed and found to be passing/Failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 15 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 7 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Copy of marking plate:

Marking Plate of EUT

TRF No. BIS_IT/S_IS13252_V1.4

Page 16 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 8 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Table – List of Attachments

Attachment No. Attachment Description No. of pages in Attachment

Attachment – 1 Photo Document 101

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.

Possible test case verdicts:


- test case does not apply to the test object ................ : N/A
- test object does meet the requirement ...................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)

Testing .......................................................................... :
Date of receipt of test item ........................................... : 10/02/2024
Date(s) of performance of tests ................................... : From 13/02/2024 to 19/03/2024
Laboratory conditions ................................................... :
Ambient Temperature................................................... : 27±2°C
Ambient Humidity ......................................................... : 50±5% Rh

TRF No. BIS_IT/S_IS13252_V1.4

Page 17 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 9 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Test item particulars .................................................. : Scanner


Equipment mobility .................................................... : movable hand-held transportable
stationary for building-in direct plug-in
Connection to the mains ............................................ : pluggable equipment [ ] type A [ ] type B
permanent connection
detachable power supply cord
non-detachable power supply cord
not directly connected to the mains
Operating condition ................................................... : continuous
rated operating / resting time:
Access location ......................................................... : operator accessible
restricted access location
Over voltage category (OVC) ................................... : OVC I OVC II OVC III OVC IV
other: SELV
Mains supply tolerance (%) or absolute mains supply
values ....................................................................... : N/A
Class of equipment ................................................... : Class I Class II Class III
Not classified
Considered current rating of protective device as a
part of the building installation (A) ............................ : N/A
Pollution degree (PD) ............................................... : PD 1 PD 2 PD 3
IP protection class .................................................... : IPXX
Altitude during operation (m) .................................... : Up to 2000
Altitude of test laboratory (m) ................................... : < 1000
Mass of equipment (kg) ............................................ : 0.187Kg
Abbreviations that may be used throughout this test report:
PE/PB .............. : protective earth/protective bonding Pri .....................: primary
CB .................... : circuit breaker sec ....................: secondary
(SW)PS ............ : (switching) power supply gnd....................: ground
HV .................... : high voltage I/O .....................: input/output
PCB ................. : printed circuit (wiring) board ii ......................... : installation instruction
TIW .................... : triple insulated wire PSU ................... : Power Supply Unit
B/I ...................... : built-in application (compliance shall be guarantee in host equipment)
F/B/S/R : Functional/Basic/Supplementary/Reinforced Insulation

TRF No. BIS_IT/S_IS13252_V1.4

Page 18 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 10 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

General product information:

4) Application details / Description of the product:


The equipment under test is Class III
Product name “Scanner”
Model No. “S602”,
INPUT: 5V 500mA

Max. specified ambient temperature (°C) ...... : 40°C

2) Differences between the models……….: N/A

Model No. tested with-in the family series . : N/A

3) Options:
The equipment was tested without any optional accessory installed. Hence, this report does not cover
parameters that are influenced by the installation of optional accessory that might affect safety in the meaning
of this standard.

TRF No. BIS_IT/S_IS13252_V1.4

Page 19 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 11 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

DISCIPLINE: ELECTRONICS
GROUP: IT EQUIPMENT

Tests relating to General Requirements EL 2100 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
1.5 Components* EL 2100-00 Verification of approvals with due P
correlation between the components
used and the approval certificates
submitted (Please see the table 1.5.1)
1.5.1 General: EL 2100-01 See below P
Components shall be complying Component certified with relevant P
with IEC 60950-1 or relevant component standard.
component standard.
Components and subassemblies N/A
approved for IEC 62368-1 can be
considered as complying with this
standard
1.5.2 Evaluation and testing of EL 2100-02 Component certified to IEC standard P
components and/or their harmonized standards are
used within their ratings
(See Table 1.5.1)
1.5.3 Thermal controls EL 2100-03 No Thermal Controls N/A
1.5.4 Transformers EL 2100-04 No Transformers N/A
1.5.5 Interconnecting cables* EL 2100-05 No internal wire used N/A
1.5.6 Capacitors bridging insulation * EL 2100-06 No such capacitors bridging insulation N/A
1.5.7 Resistors bridging insulation EL 2100-07 No such resistors bridging insulation N/A
1.5.7.1 Resistors bridging functional, EL 2100-08 See above Cl. No. 1.5.7 N/A
basic or supplementary
insulation*
1.5.7.2 Resistors bridging double or EL 2100-09 See above Cl. No. 1.5.7 N/A
reinforced insulation between a.c.
mains and other circuits
1.5.7.3 Resistors bridging double EL 2100-10 See above Cl. No. 1.5.7 N/A
insulation or reinforced insulation
between the a.c. mains supply
and circuits connected to an
antenna or coaxial cable
1.5.8 Components in equipment for IT EL 2100-11 Not for IT power Distribution system N/A
power distribution systems*
1.5.9 Surge suppressors EL 2100-12 No surge suppressors used N/A
1.5.9.1 General* EL 2100-13 See above Cl. No. 1.5.9 N/A
1.5.9.2 Protection of VDRs* EL 2100-14 See above Cl. No. 1.5.9 N/A

TRF No. BIS_IT/S_IS13252_V1.4

Page 20 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 12 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to General Requirements EL 2100 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
1.5.9.3 Bridging of functional insulation EL 2100-15 See above Cl. No. 1.5.9 N/A
by a VDR*
1.5.9.4 Bridging of basic insulation by a EL 2100-16 See above Cl. No. 1.5.9 N/A
VDR*
1.5.9.5 Bridging of supplementary, EL 2100-17 See above Cl. No. 1.5.9 N/A
double or reinforced insulation by
a VDR*

*- Total number of Requirements to be observed / inspected = 10


Total No of applicable Requirement = 01
No of Requirements for which the sample passed = 01

Total number of tests to be conducted = 08


Total No of applicable Tests = 02
No. of tests for which the sample passed = 02

Certificate: It is certified that the above tests were performed and found to be passing/ failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 21 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 13 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2101 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
1.6 Power interface* EL 2101-00 See below P
1.6.1 AC power distribution systems* EL 2101-01 Equipment not directly connected to N/A
AC mains
1.6.2 Input current EL 2101-02 See table 1.6.2 P
1.6.3 Voltage limit of hand-held EL 2101-03 Not a hand-held Equipment N/A
equipment*
1.6.4 Neutral conductor * EL 2101-04 Class III Equipment N/A

*- Total number of Requirements to be observed / inspected = 04


Total No of applicable Requirement = 01
No of Requirements for which the sample passed = 01

Total number of tests to be conducted = 01


Total No of applicable Tests = 01
No. of tests for which the sample passed = 01

Certificate: It is certified that the above tests were performed and found to be passing/ failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 22 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 14 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Marking Requirements EL 2102 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
1.7 Marking and instructions* EL 2102-00 Complies P
1.7.1 Power rating and identification See below P
markings
1.7.1.1 Power rating marking* EL 2102-01 See below P
Rated voltage(s) or voltage EL 2102-02 5V P
ranges(s) (V)*.
Multiple mains supply EL 2102-03 No multiple mains supply connection N/A
connections*.
Symbol for nature of supply, for EL 2102-04 symbol used on marking plate P
d.c. only*:
Rated frequency or rated EL 2102-05 DC supply used N/A
frequency range (Hz) *:
Rated current (mA or A)*: EL 2102-06 500mA P
1.7.1.2 Identification markings* EL 2102-07 See below P
Manufacturer’s name or trade- EL 2102-08 P
mark or identification mark *:

Model identification or type EL 2102-09 S602 P


reference *:
Symbol for Class II equipment EL 2102-10 Class III equipment N/A
only* :
Other markings and symbols*: EL 2102-11 Other marking and symbol do not P
give rise to misunderstanding
1.7.1.3 Use of graphical symbols* EL 2102-12 Graphical Symbol are used P
1.7.2 Safety instructions and marking* EL 2102-13 See below P
1.7.2.1 General EL 2102-14 Instruction manual provided with P
sufficient information
1.7.2.2 Disconnect devices* EL 2102-15 Not directly connected to mains N/A
1.7.2.3 Overcurrent protective devices* EL 2102-16 No such protective devices used N/A
1.7.2.4 IT power distribution systems* EL 2102-17 Not for IT power distribution system N/A
1.7.2.5 Operator access with a tool* EL 2102-18 No tools required N/A
1.7.2.6 Ozone* EL 2102-19 No ozone generated N/A
1.7.3 Short duty cycles* EL 2102-20 Continuous operation N/A
1.7.4 Supply voltage adjustment* EL 2102-21 No such voltage adjustment N/A
1.7.5 Power outlets on the equipment* EL 2102-22 No such power outlets N/A
TRF No. BIS_IT/S_IS13252_V1.4

Page 23 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 15 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Marking Requirements EL 2102 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
1.7.6 Fuse identification (marking, EL 2102-23 Fuse not used N/A
special fusing characteristics,
cross-reference)
Fuse(s) shall clearly and
adequately marked with fuse
number and rating*.
1.7.7 Wiring terminals EL 2102-24 See below Cl. No. 1.7.7.1 to 1.7.7.3 N/A
1.7.7.1 Protective earthing and bonding EL 2102-25 Class III equipment N/A
terminals*
1.7.7.2 Terminals for a.c. mains supply EL 2102-26 Not directly connected to mains. N/A
conductors*
1.7.7.3 Terminals for d.c. mains supply EL 2102-27 No DC main supply N/A
conductors*
1.7.8 Controls and indicators EL 2102-28 See below cl. No. 1.7.8.1 to 1.7.8.4 P

1.7.8.1 Identification, location and EL 2102-29 Functions of controls affecting safety P


marking *: are obvious regardless of language
1.7.8.2 Colours* EL 2102-30 Functional indicators are coloured P
1.7.8.3 Symbols according to IEC EL 2102-31 No symbol used N/A
60417*:
1.7.8.4 Markings using figures*: EL 2102-32 No such figures N/A
1.7.9 Isolation of multiple power EL 2102-33 No multiple power sources N/A
sources*
1.7.10 Thermostats and other EL 2102-34 No such components N/A
regulating devices*
1.7.11 Durability EL 2102-35 Marking were legible and durable P
after test
1.7.12 Removable parts* EL 2102-36 No removable parts N/A
1.7.13 Replaceable batteries* EL 2102-37 No battery used N/A
Language(s) See above N/A
1.7.14 Equipment for restricted access EL 2102-38 Not for restricted access location N/A
locations*

TRF No. BIS_IT/S_IS13252_V1.4

Page 24 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 16 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

*- Total number of Requirements to be observed / inspected = 35


Total No of applicable Requirement = 13
No of Requirements for which the sample passed = 13

Total number of tests to be conducted = 04


Total No of applicable Tests = 03
No. of tests for which the sample passed = 03

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 25 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 17 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2103 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.1 Protection from electric shock and EL 2103-00 See below P
energy hazards*
2.1.1 Protection in operator access areas* EL 2103-01 No hazardous voltage in P
operator access area
2.1.1.1 Access to energized parts EL 2103-02 Equipment powered by SELV P
Test by inspection: See above Cl. No. 2.1.1.1 P
Test with test finger (Figure 2A) See above Cl. No. 2.1.1.1 N/A
Test with test pin (Figure 2B): See above Cl. No. 2.1.1.1 N/A
Test with test probe (Figure 2C) No TNV circuits N/A
2.1.1.2 Battery compartments * EL 2103-03 No TNV circuit in battery N/A
compartment
2.1.1.3 Access to ELV wiring EL 2103-04 No ELV wiring N/A
Working voltage (Vpeak or Vrms); See above Cl. No. 2.1.1.3 N/A
minimum distance through insulation
(mm)
2.1.1.4 Access to hazardous voltage circuit EL 2103-05 No hazardous voltage circuit N/A
wiring wiring
2.1.1.5 Energy hazards : EL 2103-06 No energy hazards, powered P
by SELV only
2.1.1.6 Manual controls EL 2103-07 No Manual controls N/A
2.1.1.7 Discharge of capacitors in equipment Class III Equipment N/A
Measured voltage (V); EL 2103-08 See above Cl. No. 2.1.1.7 N/A
time-constant (s):
2.1.1.8 Energy hazards – d.c. mains supply No DC main supply N/A
a) Capacitor connected to the d.c. EL 2103-09 See above Cl. No. 2.1.1.8 N/A
mains supply :
b) Internal battery connected to the EL 2103-10 See above Cl. No. 2.1.1.8 N/A
d.c. mains supply :
2.1.1.9 Audio amplifiers to be tested EL 2103-11 No audio amplifier N/A
according to IEC 60065, cl. 9.1.1.:
2.1.2 Protection in service access areas EL 2103-12 Class III Equipment N/A
2.1.3 Protection in restricted access EL 2103-13 Not for restricted access N/A
locations locations

TRF No. BIS_IT/S_IS13252_V1.4

Page 26 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 18 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

*- Total number of Requirements to be observed / inspected = 03


Total No of applicable Requirement = 02
No of Requirements for which the sample passed = 02

Total number of tests to be conducted = 11


Total No of applicable Tests = 02
No. of tests for which the sample passed = 02

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 27 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 19 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2104 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.2 SELV circuits* EL 2104-00 See below P
2.2.2 Voltages under normal conditions EL 2104-01 Powered by SELV circuit P
2.2.3 Voltages under fault conditions EL 2104-02 Powered by SELV circuit P
2.2.4 Connection of SELV circuits to EL 2104-03 SELV to SELV circuit connection only P
other circuits* :

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 02
No of Requirements for which the sample passed = 02

Total number of tests to be conducted = 02


Total No of applicable Tests = 02
No. of tests for which the sample passed = 02

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 28 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 20 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2105 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.3 TNV circuits* EL 2105-00 No TNV Circuit N/A
2.3.1 Type of TNV circuits: EL 2105-01 See above Cl. No. 2.3 N/A
TNV-1 / TNV-2 / TNV-3
a) Limits of TNV-1: EL 2105-02 See above Cl. No. 2.3 N/A
b) Limits of TNV-2 or TNV-3: EL 2105-03 See above Cl. No. 2.3 N/A
Continuous voltages,
combination of AC and DC
values, are such that :

2.3.2 Separation from other circuits EL 2105-04 See above Cl. No. 2.3 N/A
and from accessible parts*
2.3.2.1 General Requirements EL 2105-05 See above Cl. No. 2.3 N/A
2.3.2.2 Protection by basic insulation EL 2105-06 See above Cl. No. 2.3 N/A
2.3.2.3 Protection by earthing EL 2105-07 See above Cl. No. 2.3 N/A
2.3.2.4 Protection by other EL 2105-08 See above Cl. No. 2.3 N/A
constructions :
2.3.3 Separation from hazardous EL 2105-09 See above Cl. No. 2.3 N/A
voltages
2.3.4 Connection of TNV circuits to EL 2105-10 See above Cl. No. 2.3 N/A
other circuits
2.3.5 Test for operating voltages EL 2105-11 See above Cl. No. 2.3 N/A
generated externally

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 10


Total No of applicable Tests = 00
No. of tests for which the sample passed =N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 29 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 21 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2106 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.4 Limited current circuits * EL 2106-00 No limited current circuit N/A
2.4.1 General requirements * EL 2106-01 See above Cl. No. 2.4 N/A
2.4.2 Limit values EL 2106-02 See above Cl. No. 2.4 N/A
2.4.3 Connection of limited current EL 2106-03 See above Cl. No. 2.4 N/A
circuits to other circuits*

*- Total number of Requirements to be observed / inspected = 03


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 30 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 22 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2107 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.5 Limited power sources * EL 2107-00 No limited power sources N/A
a) Inherently limited output EL 2107-01 See above Cl. No. 2.5 N/A
b) Impedance limited output EL 2107-02 See above Cl. No. 2.5 N/A
c) Regulating network limited EL 2107-03 See above Cl. No. 2.5 N/A
output under normal operating
and single fault condition
Use of integrated circuit (IC)
current limiters
d) Overcurrent protective device EL 2107-04 See above Cl. No. 2.5 N/A
limited output
Max. output voltage (V), EL 2107-05 See above Cl. No. 2.5 N/A
Max. output current (A),
Max. apparent power (VA)
Current rating of overcurrent EL 2107-06 See above Cl. No. 2.5 N/A
protective device (A)

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 06


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 31 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 23 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2108 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.6 Provisions for earthing and bonding* EL 2108-00 Class III Equipment N/A
2.6.1 Protective earthing EL 2108-01 See above Cl. No. 2.6 N/A
2.6.2 Functional earthing : EL 2108-02 See above Cl. No. 2.6 N/A
The Functional earthing either
separated from hazardous voltages
by double or reinforced insulation or
by protectively earthed screen or
conductive part separated by at least
basic insulation, or safely connected
to Protective Bonding Conductor.*
Use of symbol for functional EL 2108-03 See above Cl. No. 2.6 N/A
earthing:*
2.6.3 Protective earthing and protective EL 2108-04 See above Cl. No. 2.6 N/A
bonding conductors*
2.6.3.2 Size of protective earthing EL 2108-05 See above Cl. No. 2.6 N/A
conductors
Rated current (A), cross-sectional See above Cl. No. 2.6 N/A
area (mm2),
2.6.3.3 Size of protective bonding EL 2108-06 See above Cl. No. 2.6 N/A
conductors
Protective current Rating (A), cross- See above Cl. No. 2.6 N/A
sectional area (mm2)
2.6.3.4 Resistance of earthing conductors EL 2108-07 See above Cl. No. 2.6 N/A
and their terminations; resistance
(), voltage drop (V), test current (A),
duration (min):
2.6.3.5 Colour of insulation*: EL 2108-08 See above Cl. No. 2.6 N/A
2.6.4 Terminals See above Cl. No. 2.6 N/A
2.6.4.2 Protective earthing and bonding EL 2108-09 See above Cl. No. 2.6 N/A
terminals : Rated current(A), Type,
Nominal thread diameter (mm)
2.6.4.3 Separation of the protective earthing EL 2108-10 See above Cl. No. 2.6 N/A
conductor from protective bonding
conductors*
2.6.5 Integrity of protective earthing* See above Cl. No. 2.6 N/A
2.6.5.1 Interconnection of equipment* EL 2108-11 See above Cl. No. 2.6 N/A
2.6.5.2 Components in protective earthing EL 2108-12 See above Cl. No. 2.6 N/A
conductors and protective bonding
conductors*

TRF No. BIS_IT/S_IS13252_V1.4

Page 32 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 24 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

2.6.5.3 Disconnection of protective earth* EL 2108-13 See above Cl. No. 2.6 N/A
2.6.5.4 Parts that can be removed by an EL 2108-14 See above Cl. No. 2.6 N/A
operator*
2.6.5.5 Parts removed during servicing* EL 2108-15 See above Cl. No. 2.6 N/A
2.6.5.6 Corrosion resistance* EL 2108-16 See above Cl. No. 2.6 N/A
2.6.5.7 Screws for protective bonding* EL 2108-17 See above Cl. No. 2.6 N/A
2.6.5.8 Reliance on telecommunication EL 2108-18 See above Cl. No. 2.6 N/A
network or cable distribution system*

*- Total number of Requirements to be observed / inspected = 14


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 05


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 33 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 25 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2109 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.7 Overcurrent and earth fault EL 2109-00 Class III equipment N/A
protection in primary circuits*
2.7.1 Basic requirements: EL 2109-01 See above Cl. No. 2.7 N/A
Protection in primary circuits
against overcurrents, short-
circuits and earth faults shall be
provided, either as an integral
part of the equipment or as part
of building installation.
If pluggable equipment Type B or See above Cl. No. 2.7 N/A
permanently connected
equipment relies on protective
device external to the equipment
for protection, the equipment
installation Instructions shall so
state and shall also specify the
requirements for short-circuit
protection or overcurrent
protection or, where necessary,
for both.
2.7.2 Faults not simulated in 5.3.7* EL 2109-02 See above Cl. No. 2.7 N/A
need not be fitted as an integral
part of the equipment
2.7.3 Short-circuit backup protection EL 2109-03 See above Cl. No. 2.7 N/A
2.7.4 Number and location of protective EL 2109-04 See above Cl. No. 2.7 N/A
devices:
2.7.5 Protection by several devices* EL 2109-05 See above Cl. No. 2.7 N/A
2.7.6 Warning to service personnel*: EL 2109-06 See above Cl. No. 2.7 N/A
*- Total number of Requirements to be observed / inspected = 05
Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 02


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)
TRF No. BIS_IT/S_IS13252_V1.4

Page 34 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 26 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2110 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.8 Safety Interlocks* EL 2110-00 No safety interlocks N/A
2.8.1 General principles* EL 2110-01 See above Cl. No. 2.8 N/A
2.8.2 Protection requirements EL 2110-02 See above Cl. No. 2.8 N/A
2.8.3 Inadvertent reactivation EL 2110-03 See above Cl. No. 2.8 N/A
2.8.4 Fail-safe operation EL 2110-04 See above Cl. No. 2.8 N/A
2.8.5 Moving parts EL 2110-05 N/A
2.8.6 Overriding* EL 2110-06 See above Cl. No. 2.8 N/A
2.8.7 Switches, relays and their related EL 2110-07 See above Cl. No. 2.8 N/A
circuits
2.8.7.1 Separation distances for contact EL 2110-08 See above Cl. No. 2.8 N/A
gaps and their related circuits`
2.8.7.2 Overload test EL 2110-09 See above Cl. No. 2.8 N/A
2.8.7.3 Endurance test EL 2110-10 N/A
2.8.7.4 Electric strength test EL 2110-11 See above Cl. No. 2.8 N/A
2.8.8 Mechanical actuators EL 2110-12 See above Cl. No. 2.8 N/A

*- Total number of Requirements to be observed / inspected = 03


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 10


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 35 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 27 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2111 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.9 Electrical insulation* EL 2111-00 See Below P
2.9.1 Properties of insulating materials* EL 2111-01 Natural rubber, materials Containing P
asbestos and hygroscopic materials
are not used as insulation
2.9.2 Humidity conditioning EL 2111-02 Class III equipment N/A
Relative Humidity : 93 ±3 %, See above Cl. No.2.9.2 N/A
Temperature: t at 40 ± 2°C
Duration : 120 hours
2.9.3 Grade of insulation* EL 2111-03 Functional insulation P
2.9.4 Separation from hazardous EL 2111-04 Powered by SELV only P
voltages*
Method(s) used See above Cl. No. 2.9.4 P

*- Total number of Requirements to be observed / inspected = 04


Total No of applicable Requirement = 04
No of Requirements for which the sample passed = 04

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 36 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 28 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2112 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
2.10 Clearances, creepage distances EL 2112-00 See below P
and distances through
Insulation*
2.10.1.1 Frequency * EL 2112-01 DC Supply N/A
2.10.1.2 Pollution degrees* EL 2112-02 Pollution degree 2 P
2.10.1.3 Reduced values for functional EL 2112-03 Functional insulation Complies with P
insulation the requirements of Cl. No.5.3.4)

2.10.1.4 Intervening unconnected conductive EL 2112-04 No such parts N/A


parts
2.10.1.5 Insulation with varying dimensions EL 2112-05 No such insulation N/A
2.10.1.6 Special separation requirements EL 2112-06 No such requirements N/A
2.10.1.7 Insulation in circuits generating EL 2112-07 No such circuit N/A
starting pulses
2.10.2 Determination of working voltage EL 2112-08 Class III equipment N/A
2.10.2.2 RMS working voltage EL 2112-09 See above cl. No. 2.10.2 N/A
2.10.2.3 Peak working voltage EL 2112-10 See above cl. No. 2.10.2 N/A
2.10.3 Clearances EL 2112-11 Class III equipment N/A
2.10.3.1 General EL 2112-12 N/A
2.10.3.2 Mains transient voltages* See below N/A
a) AC mains supply * : EL 2112-13 Not directly connected to mains N/A
b) Earthed d.c. mains supplies* ..............................
EL 2112-14 : No DC mains supply N/A
c) Unearthed d.c. mains supplies* : EL 2112-15 No DC mains supply N/A
d) Battery operation* : EL 2112-16 No such battery N/A
2.10.3.3 Clearances in primary circuits EL 2112-17 Class III equipment N/A
2.10.3.4 Clearances in secondary circuits EL 2112-18 Class III equipment N/A
2.10.3.5 Clearances in circuits having EL 2112-19 No such circuit N/A
starting pulses
2.10.3.6 Transients from a.c. mains supply : EL 2112-20 Not directly connected to mains N/A
2.10.3.7 Transients from d.c. mains supply : EL 2112-21 No DC mains supply N/A
2.10.3.8 Transients from telecommunication EL 2112-22 No telecommunication networks N/A
networks and cable distribution and cable distribution systems
systems .................................................................... :
2.10.3.9 Measurement of transient voltages Not directly connected to mains N/A

TRF No. BIS_IT/S_IS13252_V1.4

Page 37 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 29 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

a) Transients from a mains supply EL 2112-23 Not directly connected to mains N/A
For an a.c. mains supply Not directly connected to mains N/A
For a d.c. mains supply No DC mains supply N/A
b) Transients from a EL 2112-24 No telecommunication network N/A
telecommunication network
2.10.4 Creepage distances* EL 2112-25 Class III equipment N/A
2.10.4.1 General EL 2112-26 See above cl. No. 2.10.4 N/A
2.10.4.2 Material group and comparative EL 2112-27 See above cl. No. 2.10.4 N/A
tracking index : CTI tests*
2.10.4.3 Minimum creepage distances EL 2112-28 See above cl. No. 2.10.4 N/A
2.10.5 Solid insulation EL 2112-29 No such insulation N/A
2.10.5.1 General EL 2112-30 N/A
2.10.5.2 Distances through insulation EL 2112-31 No such insulation N/A
2.10.5.3 Insulating compound as solid EL 2112-32 No such insulation N/A
insulation
2.10.5.4 Semiconductor devices EL 2112-33 N/A
2.10.5.5. Cemented joints EL 2112-34 No cemented joints N/A
2.10.5.6 Thin sheet material – General EL 2112-35 No Thin sheet material used N/A
2.10.5.7 Separable thin sheet material EL 2112-36 See above Cl. No. 2.10.5.6 N/A
2.10.5.8 Non-separable thin sheet material EL 2112-37 See above Cl. No. 2.10.5.6 N/A
2.10.5.9 Thin sheet material – standard test EL 2112-38 See above Cl. No. 2.10.5.6 N/A
procedure
Electric strength test as per Cl.5.2.2 See above Cl. No. 2.10.5.6 N/A
2.10.5.10 Thin sheet material – alternative EL 2112-39 See above Cl. No. 2.10.5.6 N/A
test procedure
Electric strength test as per Cl.5.2.2 See above Cl. No. 2.10.5.6 N/A
2.10.5.11 Insulation in wound components EL 2112-40 No wound components used N/A
2.10.5.12 Wire in wound components See above Cl. No. 2.10.5.11 N/A
If Peak Working voltage >71 V See above Cl. No. 2.10.5.11 N/A
a) Basic insulation not under stress EL 2112-41 See above Cl. No. 2.10.5.11 N/A
b) Basic, supplementary, reinforced EL 2112-42 See above Cl. No. 2.10.5.11 N/A
insulation
c) Compliance with Annex U EL 2112-43 N/A
d) Where two winding wires in EL 2112-44 See above Cl. No. 2.10.5.11 N/A
contact inside wound component;
angle between 45 and 90

TRF No. BIS_IT/S_IS13252_V1.4

Page 38 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 30 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

2.10.5.13 Wire with solvent-based enamel in See above Cl. No. 2.10.5.11 N/A
wound components
a) Electric strength test (Type test EL 2112-45 See above Cl. No. 2.10.5.11 N/A
as per Cl.5.2.2)
b) Electric Strength test (Routine EL 2112-46 See above Cl. No. 2.10.5.11 N/A
test as per Cl.5.2.2)
2.10.5.14 Additional insulation in wound See above Cl. No. 2.10.5.11 N/A
components
If Peak Working Voltage >71V See above Cl. No. 2.10.5.11 N/A
a) Basic insulation not under stress EL 2112-47 See above Cl. No. 2.10.5.11 N/A
b) Supplementary, reinforced EL 2112-48 See above Cl. No. 2.10.5.11 N/A
insulation
2.10.6 Construction of printed boards* See below P
2.10.6.1 Uncoated printed boards EL 2112-49 Uncoated printed boards used P
2.10.6.2 Coated printed boards EL 2112-50 Not used N/A
2.10.6.3 Insulation between conductors on EL 2112-51 No such construction N/A
the same inner surface of a printed
board
2.10.6.4 Insulation between conductors on See above Cl. No. 2.10.6.3 N/A
different surfaces of a printed
board*
a) Minimum Thickness of EL 2112-52 See above Cl. No. 2.10.6.3 N/A
insulation: 0.4mm or
b) Confirm with one of the EL 2112-53 See above Cl. No. 2.10.6.3 N/A
specification and pass the relevant
tests as per Table 2R
2.10.7 Component external terminations EL 2112-54 No such construction N/A
2.10.8 Tests on coated printed boards and Uncoated printed boards used N/A
coated components
2.10.8.1 Sample preparation and preliminary EL 2112-55 N/A
inspection*
2.10.8.2 Thermal conditioning EL 2112-56 See above Cl. No. 2.10.8 N/A
2.10.8.3 Electric strength test EL 2112-57 See above Cl. No. 2.10.8 N/A
2.10.8.4 Abrasion resistance test EL 2112-58 See above Cl. No. 2.10.8 N/A
2.10.9 Thermal cycling EL 2112-59 Class III equipment N/A
2.10.10 Test for Pollution Degree 1 EL 2112-60 Pollution degree 2 N/A
environment and insulating
compound
2.10.11 Tests for semiconductor devices EL 2112-61 N/A
and cemented joints

TRF No. BIS_IT/S_IS13252_V1.4

Page 39 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 31 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

2.10.12 Enclosed and sealed parts EL 2112-62 No such parts N/A

*- Total number of Requirements to be observed / inspected = 10


Total No of applicable Requirement = 02
No of Requirements for which the sample passed = 02

Total number of tests to be conducted = 53


Total No of applicable Tests = 02
No. of tests for which the sample passed = 02

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 40 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 32 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Wiring EL 2113 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
3.0 Wiring, connections and supply* EL 2113-00 See below P
3.1.1 Current rating and overcurrent EL 2113-01 No internal wire used N/A
protection
3.1.2 Protection against mechanical EL 2113-02 No internal wire used N/A
damage*
3.1.3 Securing of internal wiring* EL 2113-03 No internal wire used N/A

3.1.4 Insulation of conductors EL 2113-04 No internal wire used N/A


3.1.5 Beads and ceramic insulators EL 2113-05 Beads and ceramic insulators are N/A
not used
3.1.6 Screws for electrical contact EL 2113-06 No such screws used N/A
pressure*
3.1.7 Insulating materials in electrical EL 2113-07 No such construction N/A
connections*
3.1.8 Self-tapping and spaced thread EL 2113-08 No such screws used N/A
screws*
3.1.9 Termination of conductors: EL 2113-09 No such termination N/A
10 N pull test
3.1.10 Sleeving on wiring* EL 2113-10 No sleeving used N/A

*- Total number of Requirements to be observed / inspected = 07


Total No of applicable Requirement = 01
No of Requirements for which the sample passed = 01

Total number of tests to be conducted = 04


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 41 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 33 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Wiring EL 2114 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
3.2 Connection to a main supply* EL 2114-00 N/A
3.2.1 Means of connection See below N/A
3.2.1.1 Connection to an a.c. mains supply* EL 2114-01 Equipment not directly connected N/A
to mains
3.2.1.2 Connection to a d.c. mains supply* EL 2114-02 No DC mains supply N/A
3.2.2 Multiple supply connections EL 2114-03 No multiple supply connections N/A
3.2.3 Permanently connected equipment EL 2114-04 Not a Permanently connected N/A
equipment
3.2.4 Appliance inlets: EL 2114-05 Appliance inlets not used N/A
Are so Located that parts at
hazardous voltage are not accessible
during insertion or removal of the
connector, connector can be inserted
without difficulty and after insertion of
the connector, the equipment is not
supported by the connector for any
position of normal use on a flat
surface
(appliance inlets complying with IEC
60309 or IEC 60320 considered to
comply with this requirement.
3.2.5 Power supply cords Power supply cords not used N/A
3.2.5.1 AC power supply cords* EL 2114-06 See above Cl. No. 3.2.5 N/A
Rated current (A), cross-sectional See above Cl. No. 3.2.5 N/A
area (mm²), AWG
3.2.5.2 DC power supply cords* EL 2114-07 See above Cl. No. 3.2.5 N/A
3.2.6 Cord anchorages and strain relief See above Cl. No. 3.2.5 N/A
Mass of the equipment: EL 2114-08 See above Cl. No. 3.2.5 N/A
Pull Force (N):
b) Longitudinal displacement: 2 mm EL 2114-09 See above Cl. No. 3.2.5 N/A
(Max)
3.2.7 Protection against mechanical EL 2114-10 See above Cl. No. 3.2.5 N/A
damage
3.2.8 Cord guards See above Cl. No. 3.2.5 N/A
4) ........................................................................
EL 2114-11D See above Cl. No. 3.2.5 N/A
iameter or minor dimension D
(mm):
Test mass (g):

TRF No. BIS_IT/S_IS13252_V1.4

Page 42 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 34 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

b) Radius of curvature of cord: 1.5 D EL 2114-12 See above Cl. No. 3.2.5 N/A
(Min)
3.2.9 Supply wiring space EL 2114-13 See above Cl. No. 3.2.5 N/A

*- Total number of Requirements to be observed / inspected = 05


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 09


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 43 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 35 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Wiring EL 2115 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
3.3 Wiring terminals for connection EL 2115-00 No wiring terminals used N/A
of external conductors*
3.3.1 Wiring terminals* EL 2115-01 See above Cl. No. 3.3 N/A
3.3.2 Connection of non-detachable EL 2115-02 See above Cl. No. 3.3 N/A
power supply cords
3.3.3 Screw terminals* EL 2115-03 See above Cl. No. 3.3 N/A
3.3.4 Conductor sizes to be EL 2115-04 See above Cl. No. 3.3 N/A
connected
Rated current (A), cord/cable See above Cl. No. 3.3 N/A
type, cross-sectional area
(mm2)
3.3.5 Wiring terminal sizes EL 2115-05 See above Cl. No. 3.3 N/A
Rated current (A), type, nominal See above Cl. No. 3.3 N/A
thread diameter (mm)
3.3.6 Wiring terminal design EL 2115-06 See above Cl. No. 3.3 N/A
3.3.7 Grouping of wiring terminals* EL 2115-07 See above Cl. No. 3.3 N/A
3.3.8 Stranded wire EL 2115-08 See above Cl. No. 3.3 N/A

*- Total number of Requirements to be observed / inspected = 04


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 05


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 44 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 36 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Wiring EL 2116 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
3.4 Disconnection from the mains EL 2116-00 Equipment not directly connected to N/A
supply* mains
3.4.1 General Requirement EL 2116-01 See above Cl. No. 3.4 N/A
A disconnect device or devices
shall be provided to disconnect
the equipment from the mains
supply for servicing.
3.4.2 Disconnect devices* EL 2116-02 See above Cl. No. 3.4 N/A
3.4.3 Permanently connected EL 2116-03 See above Cl. No. 3.4 N/A
equipment*
3.4.4 Parts which remain energized* EL 2116-04 See above Cl. No. 3.4 N/A
3.4.5 Switches in flexible cords* EL 2116-05 See above Cl. No. 3.4 N/A
3.4.6 Number of poles – single-phase EL 2116-06 See above Cl. No. 3.4 N/A
and d.c. equipment*
3.4.7 Number of poles – three-phase EL 2116-07 See above Cl. No. 3.4 N/A
equipment*
3.4.8 Switches as disconnect devices* EL 2116-08 See above Cl. No. 3.4 N/A
3.4.9 Plugs as disconnect devices* EL 2116-09 See above Cl. No. 3.4 N/A
3.4.10 Interconnected equipment* EL 2116-10 See above Cl. No. 3.4 N/A
3.4.11 Multiple power sources* EL 2116-11 See above Cl. No. 3.4 N/A

*- Total number of Requirements to be observed / inspected = 11


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed =N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 45 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 37 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Wiring EL 2117 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
3.5 Interconnection of equipment* EL 2117-00 Comply P
3.5.1 General requirements* EL 2117-01 See below P
3.5.2 Types of interconnection EL 2117-02 SELV to SELV connections only P
circuits*
3.5.3 ELV circuits as interconnection EL 2117-03 No ELV Circuit N/A
circuits *
3.5.4 Data ports for additional EL 2117-04 No data ports for additional equipment N/A
equipment

*- Total number of Requirements to be observed / inspected = 04


Total No of applicable Requirement = 03
No of Requirements for which the sample passed = 03

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 46 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 38 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Mechanical Properties EL 2118 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
4 PHYSICAL REQUIREMENTS* EL 2118-00 See below P
4.1 Stability EL 2118-01 Mass of equipment is 0.187Kg N/A
a) A unit having a mass of 7 kg EL 2118-02 Mass < 7 kg N/A
or more shall not fall over when
tilted to an angle of 10° from its
normal upright position.
Alternatively, the unit is placed in
its intended position of use on a
plane, inclined at an angle of 10°
to the horizontal, and then
rotated slowly through an angle
of 360° about its normal vertical
axis.
b) A floor-standing unit having a EL 2118-03 Not a floor standing equipment N/A
mass of 25 kg or more shall not
fall over when a force equal to
20 % of the weight of the unit,
but not more than 250 N, is
applied in any direction except
upwards, at a height not
exceeding 2 m from the floor.
c) A floor-standing unit shall not EL 2118-04 Not a floor standing equipment N/A
fall over when a constant
downward force of 800 N is
applied at the point of maximum
moment to any horizontal
surface of at least 125 mm by at
least 200 mm, at a height up to
1 m from the floor.

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 01
No of Requirements for which the sample passed = 01

Total number of tests to be conducted = 04


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 47 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 39 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Mechanical Properties EL 2119 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
4.2 Mechanical Strength EL 2119-00 See below P
4.2.1 General EL 2119-01 Adequate mechanical strength P
4.2.2 Steady force test, 10 N EL 2119-02 No such parts N/A
4.2.3 Steady force test, 30 N EL 2119-03 No such parts N/A
4.2.4 Steady force test, 250 N EL 2119-04 Force applied on each side of P
enclosure.
Result No damage, No hazards
4.2.5 Impact test EL 2119-05 No such equipment N/A
a) Fall test as per Fig. 4A EL 2119-06 See above Cl. No. 4.2.5 N/A
b) Swing test as per Fig. 4A EL 2119-07 See above Cl. No. 4.2.5 N/A
4.2.6 Drop test; EL 2119-08 Dropped from a height of 750 mm P
height (mm) : Result No damage, No Hazards
4.2.7 Stress relief test EL 2119-09 Test performed at 70°C for 7 hours, P
No distortion occurs in enclosure
4.2.8 Cathode Ray Tubes EL 2119-10 N/A
4.2.9 High Pressure Lamps* EL 2119-11 No such lamps Used N/A
4.2.10 Wall or ceiling mounted EL 2119-12 Not a wall or ceiling mounted N/A
equipment; force(N) equipment

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 12


Total No of applicable Tests = 05
No. of tests for which the sample passed = 05

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 48 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 40 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Mechanical Properties EL 2120 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
4.3 Design and Construction* EL 2120-00 See below P
4.3.1 Edges and corners* EL 2120-01 All edges or corners accessible to P
operators are rounded and smoothed
4.3.2 Handles and manual controls; EL 2120-02 Handles and manual controls are not N/A
force (N) .....................................................................
used :
4.3.3 Adjustable controls EL 2120-03 No such controls used N/A
4.3.4 Securing of parts EL 2120-04 Parts are secured against mechanical P
stress occurring in normal use
4.3.5 Connections by Plugs and EL 2120-05 No plug and sockets used N/A
Sockets*
4.3.6 Direct plug-in equipment EL 2120-06 No direct plug-in equipment N/A
Torque EL 2120-07 See above Cl. No. 4.3.6 N/A
Compliance with the relevant EL 2120-08 See above Cl. No. 4.3.6 N/A
mains plug standard
4.3.7 Heating elements in earthed EL 2120-09 No heating elements used N/A
equipment*
4.3.8 Batteries No battery used N/A
Portable secondary sealed
cells and batteries (other than
button) containing alkaline or
other non-acid electrolyte shall
comply with IEC 62133
a) Overcharging of a EL 2120-10 See above cl. No. 4.3.8 N/A
rechargeable battery
b) Unintentional charging of a EL 2120-11 See above cl. No. 4.3.8 N/A
non-rechargeable battery
c) Reverse charging of a EL 2120-12 See above cl. No. 4.3.8 N/A
rechargeable battery
d) Excessive discharging rate EL 2120-13 See above cl. No. 4.3.8 N/A
for any battery
e) Electric strength as per EL 2120-14 See above cl. No. 4.3.8 N/A
Cl.5.3.9.2
4.3.9 Oil & grease* EL 2120-15 Oil & grease are not used N/A
4.3.10 Dust, powders, liquids and EL 2120-16 Equipment neither use nor produce N/A
gases them

TRF No. BIS_IT/S_IS13252_V1.4

Page 49 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 41 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

4.3.11 Containers for liquids or gases EL 2120-17 Equipment does not contain liquid or N/A
gases

4.3.12 Flammable liquids EL 2120-18 No flammable liquids N/A


4.3.13 Radiation No radiation used N/A
4.3.13.2 Ionizing radiation EL 2120-19 N/A
4.3.13.3 Effect of ultraviolet (UV) EL 2120-20 N/A
radiation on materials
4.3.13.4 Human exposure to ultraviolet EL 2120-21 N/A
(UV) radiation
4.3.13.5 Lasers (including laser diodes) N/A
and LED’s:
4.3.13.5.1 Lasers (including laser diodes) EL 2120-22 N/A
For laser see IEC 60825-1,
respective part as applicable.
Laser class ............................................................... : N/A
4.3.13.5.2 Light emitting diodes (LED’s) EL 2120-23 low power LED are used for functional N/A
indicators
4.3.13.6 Other types* EL 2120-24 No other type of radiation N/A

*- Total number of Requirements to be observed / inspected = 06


Total No of applicable Requirement = 02
No of Requirements for which the sample passed = 02

Total number of tests to be conducted = 19


Total No of applicable Tests = 01
No. of tests for which the sample passed = 01

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 50 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 42 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Mechanical Properties EL 2121 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
4.4 Protection against hazardous EL 2121-00 No moving parts in the equipment N/A
moving parts
4.4.1 General EL 2121-01 See above Cl. No. 4.4 N/A
4.4.2 Protection in operator access EL 2121-02 See above Cl. No. 4.4 N/A
areas
4.4.3 Protection in restricted access EL 2121-03 See above Cl. No. 4.4 N/A
locations *
4.4.4 Protection in service access EL 2121-04 See above Cl. No. 4.4 N/A
areas*
4.4.5 Protection against moving fan EL 2121-05 See above Cl. No. 4.4 N/A
blades
4.4.5.1 General* EL 2121-06 See above Cl. No. 4.4 N/A
Not considered likely to cause EL 2121-07 See above Cl. No. 4.4 N/A
pain or injury. A) ……..….:
Is considered likely to cause EL 2121-08 See above Cl. No. 4.4 N/A
pain, not injury. B)
Considered likely to cause EL 2121-09 See above Cl. No. 4.4 N/A
injury. C)………………...……:
4.4.5.2 Protection for users* EL 2121-10 See above Cl. No. 4.4 N/A
Use of symbol or warning* EL 2121-11 See above Cl. No. 4.4 N/A
4.4.5.3 Protection for service persons* EL 2121-12 See above Cl. No. 4.4 N/A
Use of symbol or warning * EL 2121-13 See above Cl. No. 4.4 N/A

*- Total number of Requirements to be observed / inspected = 07


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 07


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 51 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 43 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Thermal Properties EL 2122 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
4.5 Thermal Requirements* EL 2122-00 See below P
4.5.1 General EL 2122-01 See table 4.5 P
4.5.2 Temperature tests EL 2122-02 See table 4.5 P
4.5.3 Temperature limits for materials* EL 2122-03 See table 4.5 P
4.5.4 Touch temperature limits* EL 2122-04 See table 4.5 P
4.5.5 Resistance to abnormal heat EL 2122-05 Class III equipment powered by SELV N/A
only

*- Total number of Requirements to be observed / inspected = 03


Total No of applicable Requirement = 03
No of Requirements for which the sample passed = 03

Total number of tests to be conducted = 03


Total No of applicable Tests = 02
No. of tests for which the sample passed = 02

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 52 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 44 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Mechanical Properties EL 2123 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
4.6 Openings in enclosures* EL 2123-00 N/A
4.6.1 Top and side openings EL 2123-01 Transportable equipment N/A
Dimensions (mm): See above Cl. No. 4.6.1 N/A
4.6.2 Bottoms of fire enclosures: EL 2123-02 See above Cl. No. 4.6.1 N/A
Construction of the bottom, See above Cl. No. 4.6.1 N/A
dimensions (mm):
4.6.3 Doors or covers in fire EL 2123-03 No such doors or covers N/A
enclosures*
4.6.4 Openings in transportable EL 2123-04 See below N/A
equipment
4.6.4.1 Constructional design measures EL 2123-05 No such openings N/A
Dimensions (mm) See above Cl. No. 4.6.4.1 N/A
4.6.4.2 Evaluation measures for larger EL 2123-06 See above Cl. No. 4.6.4.1 N/A
openings
4.6.4.3 Use of metallized parts EL 2123-07 No metallized parts N/A
4.6.5 Adhesives for constructional EL 2123-08 No adhesives used N/A
purposes: Compliance is
checked by examination of the
construction and of the available
data. If such data is not
available, compliance is
checked by the following tests.
EL 2123-09 See
4)......................................................................... T above Cl. No. 4.6.5 N/A
emperature
Conditioning at:
100 °C ± 2 °C for one week; or
90 °C ± 2 °C for three weeks;
or
82 °C ± 2 °C for eight weeks.
After temperature conditioning EL 2123-10 See above Cl. No. 4.6.5 N/A
b) Leave the sample between
20°C to 30°C for 1 hour
c) Place the sample at EL 2123-11 See above Cl. No. 4.6.5 N/A
- 40°C±2°C for 4 hours

TRF No. BIS_IT/S_IS13252_V1.4

Page 53 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 45 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

d) Remove and allow the EL 2123-12 See above Cl. No. 4.6.5 N/A
sample to come to any
convenient temperature
between 20 °C and
30 °C for 8 h;
e) Place the sample in a cabinet EL 2123-13 See above Cl. No. 4.6.5 N/A
at 91 % to 95 % relative
humidity for 72 h;
f) Remove the sample and leave EL 2123-14 See above Cl. No. 4.6.5 N/A
it at any convenient temperature
between 20 °C and 30 °C for 1
h;
g) Place the sample in an oven EL 2123-15 See above Cl. No. 4.6.5 N/A
at the temperature used for the
temperature conditioning for 4 h;
h) Remove the sample and EL 2123-16 See above Cl. No. 4.6.5 N/A
allow it to reach any convenient
temperature between 20 °C; and
30 °C for 8 h.
i) The sample is then EL 2123-17 See above Cl. No. 4.6.5 N/A
immediately subjected to the
tests of Cl.4.2 as applicable.

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 16


Total No of applicable Tests = 00
No. of tests for which the sample passed =N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 54 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 46 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Fire Safety EL 2124 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
4.7 Resistance to fire* EL 2124-00 See below P
4.7.1 Reducing the risk of ignition and See below P
spread of flame
Method 1, selection and EL 2124-01 Method 1 used P
application of components wiring (See table 1.5.1)
and materials OR
Method 2, application of all of EL 2124-02 Method 2 not used N/A
simulated fault condition tests
4.7.2 Conditions for a fire enclosure* Certified material used P
(See table 1.5.1)
4.7.2.1 Parts requiring a fire enclosure* EL 2124-03 Class III equipment powered by SELV P
only
4.7.2.2 Parts not requiring a fire EL 2124-04 No such parts N/A
enclosure
4.7.3 Materials* EL 2124-05 See below Cl. No. 4.7.3.1 to 4.7.3.5 P
4.7.3.1 General* EL 2124-06 See below P
a) Class of material used* EL 2124-07 Certified material used P
(See table 1.5.1)
b) Where HB40 CLASS EL 2124-08 HB75 Material used P
MATERIAL, HB75 CLASS Material passing the glow wire test at
MATERIAL or HBF CLASS 550˚C according to IEC 60695-2-11
FOAMED MATERIAL, is (See table 4.7)
required,
material passing the glow-wire
test at 550 °C according to IEC
60695-2-11 is acceptable as an
alternative.
c) Where it is not practical to EL 2124-09 V-0 class material used P
protect components against
overheating under fault
conditions, the components shall
be mounted on V-1 CLASS
MATERIAL. Additionally, such
components shall be separated
from material of a class lower
than V-1 CLASS MATERIAL by
at least 13 mm of air, or by a
solid barrier of V-1 CLASS
MATERIAL.
4.7.3.2 Materials for fire enclosures Certified material used P
(See table 1.5.1)
TRF No. BIS_IT/S_IS13252_V1.4

Page 55 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 47 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

a) For MOVABLE EQUIPMENT EL 2124-10 See above Cl. No. 4.7.3.2 P


having a total mass not
exceeding 18 kg, the material of
a FIRE ENCLOSURE, in the
thinnest significant wall
thickness used, shall be of V-1
CLASS MATERIAL or shall pass
the test of Clause A.2.
b) For MOVABLE EQUIPMENT EL 2124-11 No such equipment N/A
having a total mass exceeding
18 kg and for all STATIONARY
EQUIPMENT, the material of a
FIRE ENCLOSURE, in the
thinnest significant wall
thickness used, shall be of 5VB
CLASS MATERIAL or shall pass
the test of Clause A.1.
c) Materials for components that EL 2124-12 No such openings N/A
fill an opening in a FIRE
ENCLOSURE, and that are
intended to be mounted in this
opening shall:
be of V-1 CLASS MATERIAL;
or
pass the tests of Clause A.2; or
comply with the flammability
requirements of the relevant IEC
component standard
d) Plastic materials of a FIRE EL 2124-13 No such arcing parts N/A
ENCLOSURE shall be located
more than 13 mm through air
from arcing parts such as
unenclosed commutators and
unenclosed switch contacts.

TRF No. BIS_IT/S_IS13252_V1.4

Page 56 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 48 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

e) Plastic materials of a FIRE EL 2124-14 No such construction N/A


ENCLOSURE located less than
13mm through air from non-
arcing parts which, under any
condition of normal or abnormal
operation, could attain a
temperature sufficient to ignite
the material, shall be capable of
passing the test of IEC 60695-2-
20.
The average time to ignition of
the samples shall be not less
than 15sec. If the sample melts
through without igniting, the time
at which this occurs is not
considered to be the time to
ignition.
4.7.3.3 Materials for components and See below N/A
other parts outside fire
enclosures *
EL 2124-15 NoMsuch class material used
4)......................................................................... N/A
aterials shall be of :
− HB75 CLASS MATERIAL if
the thinnest significant thickness
of this material is < 3 mm,
or
− HB40 CLASS MATERIAL if
the thinnest significant thickness
of this material is ≥ 3 mm,
or
− HBF CLASS FOAMED
MATERIAL. *

TRF No. BIS_IT/S_IS13252_V1.4

Page 57 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 49 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

b) Connectors shall comply with EL 2124-16 No such class material used N/A
one of the following:
− be made of V-2 CLASS
MATERIAL; or
− pass the tests of Clause A.2;
or
− comply with the flammability
requirements of the relevant IEC
component standard; or
− be mounted on V-1 CLASS
MATERIAL and be of a small
size; or
− be located in a SECONDARY
CIRCUIT supplied by a power
source that is limited to a
maximum of 15 VA (see 1.4.11)
under normal operating
conditions and after a single
fault
in the equipment (see 1.4.14).
4.7.3.4 Materials for components and Certified material used P
other parts inside fire enclosures
EL 2124-17 V-0
4)......................................................................... I class material used P
nside FIRE
ENCLOSURES,
materials for
components and other
parts shall comply with
one of the following:
− be of V-2 CLASS MATERIAL
or
HF-2 CLASS FOAMED
MATERIAL; or
− pass the flammability test
described in Clause A.2; or
− meet the flammability
requirements of a relevant IEC
component standard that
includes such requirements.
Requirements for voltage EL 2124-18 No such components used N/A
dependent resistors (VDR’s)
are in Annex Q.*

TRF No. BIS_IT/S_IS13252_V1.4

Page 58 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 50 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

4.7.3.5 Materials for air filter assemblies EL 2124-19 Air filter assembly not used N/A
:
Air filter assemblies shall be
constructed of V-2 CLASS
MATERIAL, or HF-2 CLASS
FOAMED
MATERIAL.
4.7.3.6 Materials used in high-voltage No such components used N/A
components
EL 2124-20 NoHsuch components used
4)......................................................................... N/A
igh-voltage components
operating at peak-to-
peak voltages
exceeding 4 kV shall
either be
of V-2 CLASS MATERIAL, or
HF-2 CLASS FOAMED
MATERIAL, or comply with 14.4
of IEC 60065 or
pass the needle flame test
according to IEC 60695-11-5.
b) Compliance is checked by EL 2124-21 No such components used N/A
inspection of the equipment and
material data sheets and, if
necessary, by
− the tests for V-2 CLASS
MATERIAL or HF-2 CLASS
FOAMED MATERIAL; or
− the test described in 14.4 of
IEC 60065; or
− the needle flame test
according to IEC 60695-11-5.
c) In addition to above, the EL 2124-22 No such components used N/A
following details apply, referring
to clauses of IEC 60695-11-5:
Clause 7 - Severities
Clause 8 – Conditioning EL 2124-23 No such components used N/A
Clause 11 – Evaluation of test EL 2124-24 No such components used N/A
results

TRF No. BIS_IT/S_IS13252_V1.4

Page 59 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 51 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

*- Total number of Requirements to be observed / inspected = 07


Total No of applicable Requirement = 05
No of Requirements for which the sample passed = 05

Total number of tests to be conducted = 18


Total No of applicable Tests = 04
No. of tests for which the sample passed = 04
Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 60 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 52 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Insulating Properties EL 2125 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
5.0 ELECTRICAL EL 2125-00 P
REQUIREMENTS AND
SIMULATED ABNORMAL
CONDITIONS*
5.1 Touch current and protective EL 2125-01 Class III equipment N/A
conductor current*
5.1.2 Configuration of equipment EL 2125-02 See above Cl. No. 5.1 N/A
under test (EUT)*
5.1.2.1 Single connection to an a.c. EL 2125-03 See above Cl. No. 5.1 N/A
mains supply*
5.1.2.2 Redundant multiple connections EL 2125-04 See above Cl. No. 5.1 N/A
to an a.c. mains supply*
5.1.2.3 Simultaneous multiple EL 2125-05 See above Cl. No. 5.1 N/A
connections to an a.c. mains
supply
5.1.3 Test circuit EL 2125-06 See above Cl. No. 5.1 N/A
5.1.4 Application of measuring EL 2125-07 See above Cl. No. 5.1 N/A
instrument
5.1.5 Test procedure EL 2125-08 See above Cl. No. 5.1 N/A
5.1.6 Test measurements See above Cl. No. 5.1 N/A
a) r.m.s value of voltage, U2 EL 2125-09 See above Cl. No. 5.1 N/A
measured using the instrument
as per Fig. D.1 or
r.m.s value of current measured
using the instrument as per Fig.
D.2
Alternatively, peak value of
voltage, U2, is measured using
the measuring instrument
described in Clause D.1
b) Measured touch current (mA): EL 2125-10 See above Cl. No. 5.1 N/A
c) Calculated value of TOUCH EL 2125-11 See above Cl. No. 5.1 N/A
CURRENT (mA) = U2 / 500
d) Measured protective EL 2125-12 See above Cl. No. 5.1 N/A
conductor current(mA)
e) Max. protective conductor EL 2125-13 See above Cl. No. 5.1 N/A
current =5% of Input current
5.1.7 Equipment with touch current EL 2125-14 See above Cl. No. 5.1 N/A
exceeding 3.5 mA

TRF No. BIS_IT/S_IS13252_V1.4

Page 61 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 53 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

5.1.7.1 General EL 2125-15 See above Cl. No. 5.1 N/A


5.1.7.2 Simultaneous multiple EL 2125-16 See above Cl. No. 5.1 N/A
connections to the supply
5.1.8 Touch currents to EL 2125-17 See above Cl. No. 5.1 N/A
telecommunication networks
and cable distribution systems
and from telecommunication
networks
5.1.8.1 Limitation of the touch current to EL 2125-18 See above Cl. No. 5.1 N/A
a telecommunication network or
to a cable distribution system
Supply voltage (V) See above Cl. No. 5.1 N/A
Measured touch current (mA) See above Cl. No. 5.1 N/A
Max. allowed touch current (mA) See above Cl. No. 5.1 N/A
5.1.8.2 Summation of touch currents EL 2125-19 See above Cl. No. 5.1 N/A
from telecommunication
networks
a) EUT with earthed See above Cl. No. 5.1 N/A
telecommunication ports:
b) EUT whose See above Cl. No. 5.1 N/A
telecommunication ports have
no reference to protective earth

*- Total number of Requirements to be observed / inspected = 05


Total No of applicable Requirement = 01
No of Requirements for which the sample passed = 01

Total number of tests to be conducted = 15


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 62 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 54 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Insulating Properties EL 2126 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
5.2 Electric strength* EL 2126-00 Class III equipment N/A
5.2.1 General* EL 2126-01 See above Cl. No. 5.2 N/A
5.2.2 Test procedure See above Cl. No. 5.2 N/A
EL 2126-02 See
4)......................................................................... T above Cl. No. 5.2 N/A
he test voltages for
electric strength for the
appropriate grade of
insulation
[FUNCTIONAL
INSULATION if required by
5.3.4 b), BASIC INSULATION,
SUPPLEMENTARY
INSULATION or
REINFORCED INSULATION]
are as specified in either:
− Table 5B using the PEAK
WORKING VOLTAGE (U), as
determined in 2.10.2; or
− Table 5C using the
REQUIRED WITHSTAND
VOLTAGE, as determined in
G.4.

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed =N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 63 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 55 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Insulating Properties EL 2127 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
5.3 Abnormal operating and fault EL 2127-00 See below P
conditions
5.3.1 Protection against overload and EL 2127-01 See table 5.3 P
abnormal operation
5.3.2 Motors EL 2127-02 See Annex B P
5.3.3 Transformers EL 2127-03 No transformer used N/A
5.3.4 Functional insulation: EL 2127-04 Complies with requirements of Cl. No. P
5.3.4 c)
5.3.5 Electromechanical components EL 2127-05 No electromechanical components N/A
5.3.6 Audio amplifiers in ITE: EL 2127-06 No such equipment N/A
5.3.7 Simulation of faults EL 2127-07 See table 5.3 P
5.3.8 Unattended equipment EL 2127-08 No unattended equipment N/A
5.3.9 Compliance criteria for abnormal See table 5.3 P
operating and fault conditions*
5.3.9.1 During the tests EL 2127-09 No fire occurred, No molten metal P
emitted and no distortion of enclosure
5.3.9.2 After the tests EL 2127-10 Since it is only functional insulation N/A
and as per other conditions no test
required

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 11


Total No of applicable Tests = 06
No. of tests for which the sample passed = 06

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 64 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 56 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Communicating Connection EL 2128 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
6.1 Protection of telecommunication EL 2128-00 Not for connection to N/A
network service persons, and telecommunication network
users of other equipment
connected to the network, from
hazards in the equipment
6.1.1 Protection from hazardous EL 2128-01 See above Cl. No.6.1 N/A
voltages
6.1.2 Separation of the See above Cl. No.6.1 N/A
telecommunication network from
earth*
6.1.2.1 Requirements: EL 2128-02 See above Cl. No.6.1 N/A
- Surge suppressors that bridge
the insulation shall have a
minimum rated operating
voltage Uop of
Uop =Upeak + ΔUsp + ΔUsa
Where Upeak is 360V or 180V
ΔUsp is the maximum increase of
the rated operating voltage due
to variations in component
production(If not specified by the
manufacturer, shall be taken as
10% of the rated operating
voltage of the component)
ΔUsa is the maximum increase of
the rated operating voltage due
to the component ageing over
the expected life of the
equipment(If not specified by the
manufacturer, shall be taken as
10% of the rated operating
voltage of the component)
-Insulation is subjected to
electric strength test according
to 5.2.2. The a.c test voltage is
1.5kV or 1.0kV
- Components bridging the
insulation that are left in place
during electric strength testing
shall not be damaged. There
shall be no breakdown of
insulation during electric
strength testing.

TRF No. BIS_IT/S_IS13252_V1.4

Page 65 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 57 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
6.1.2.2 Exclusions EL 2128-03 See above Cl. No.6.1 N/A

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 04


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 66 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 58 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Communicating Connection EL 2129 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
6.2 Protection of equipment users EL 2129-00 Not for connection to N/A
from overvoltages on telecommunication network
telecommunication networks*
6.2.1 Separation requirements EL 2129-01 See above Cl. No. 6.2 N/A
6.2.2 Electric strength test procedure EL 2129-02 See above Cl. No. 6.2 N/A
6.2.2.1 Impulse test EL 2129-03 See above Cl. No. 6.2 N/A
6.2.2.2 Steady-state test EL 2129-04 See above Cl. No. 6.2 N/A
6.2.2.3 Compliance criteria EL 2129-05 See above Cl. No. 6.2 N/A

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 05


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 67 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 59 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Communicating Connection EL 2130 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
6.3 Protection of the EL 2130-00 Not for connection to N/A
telecommunication wiring telecommunication wiring system
system from overheating

a)If current limiting is due to the EL 2130-01 See above Cl. No.6.3 N/A
inherent impedance of the
power source, the output current
into any resistive load, including
a short-circuit, is measured. The
current limit shall not be
exceeded after 60 s of test.
Max. output current (A) :
b) If current limiting is provided EL 2130-02 See above Cl. No.6.3 N/A
by an overcurrent protective
device having a specified
time/current characteristic:
– the time/current characteristic
shall show that a current equal
to 110 % of the current limit will
be interrupted within 60 min; and
c) the output current into any EL 2130-03 See above Cl. No.6.3 N/A
resistive load, including a short-
circuit, with the overcurrent
protective device bypassed,
measured after 60 s of test, shall
not exceed 1 000/U,
where U is the output voltage
measured in accordance with
1.4.5 with all load circuits
disconnected.

TRF No. BIS_IT/S_IS13252_V1.4

Page 68 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 60 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

d) If current limiting is provided EL 2130-04 See above Cl. No.6.3 N/A


by an overcurrent protective
device that does not have a
specified time/current
characteristic:
– the output current into any
resistive load, including a short-
circuit, shall not exceed the
current limit after 60 s of test;
and
– the output current into any
resistive load, including a short-
circuit, with the overcurrent
protective device bypassed,
measured after 60 s of test, shall
not exceed 1 000/U, where
U is the output voltage
measured in accordance with
1.4.5 with all load circuits
disconnected.

*- Total number of Requirements to be observed / inspected =00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 05


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 69 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 61 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Connection to cable distribution system EL 2131 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
7 Connection to cable distribution EL 2131-00 Not for Connection to cable N/A
systems* distribution systems
7.1 General requirements* EL 2131-01 See above Cl. No.7 N/A
7.2 Protection of cable distribution EL 2131-02 See above Cl. No.7 N/A
system service persons, and
users of other equipment
connected to the system, from
hazardous voltages in the
equipment
7.3 Protection of equipment users EL 2131-03 See above Cl. No.7 N/A
from overvoltages on the cable
distribution system
7.4 Insulation between primary EL 2131-04 See above Cl. No.7 N/A
circuits and cable distribution
systems
7.4.1 General EL 2131-05 See above Cl. No.7 N/A
7.4.2 Voltage surge test EL 2131-06 See above Cl. No.7 N/A
7.4.3 Impulse test EL 2131-07 See above Cl. No.7 N/A

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 06


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 70 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 62 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Fire Safety EL 2132 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
A ANNEX A, TESTS FOR EL 2132-00 See below P
RESISTANCE TO HEAT AND
FIRE
A.1 Flammability test for fire EL 2132-01 Mass < 18Kg N/A
enclosures of movable
equipment having a total mass
exceeding 18 kg, and of
stationary equipment (see
4.7.3.2)
A.1.1 Samples: EL 2132-02 See above Cl. No. A.1 N/A
Wall thickness (mm): See above Cl. No. A.1 N/A
A.1.2 Conditioning of samples; EL 2132-03 See above Cl. No. A.1 N/A
temperature (C):
A.1.3 Mounting of samples: EL 2132-04 See above Cl. No. A.1 N/A
A.1.4 Test flame (see IEC 60695-11- EL 2132-05 See above Cl. No. A.1 N/A
3)
Flame A, B, C or D: See above Cl. No. A.1 N/A
A.1.5 Test procedure EL 2132-06 See above Cl. No. A.1 N/A
A.1.6 Compliance criteria EL 2132-07 See above Cl. No. A.1 N/A
Sample 1 burning time (s): See above Cl. No. A.1 N/A
Sample 2 burning time (s): See above Cl. No. A.1 N/A
Sample 3 burning time (s): See above Cl. No. A.1 N/A
A.2 Flammability test for fire EL 2132-08 Certified material used P
enclosures of movable (see table 1.5.1)
equipment having a total mass
not exceeding 18 kg, and for
material and components
located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
A.2.1 Samples, material: EL 2132-09 See above Cl. No. A.2 N/A
Wall thickness (mm): See above Cl. No. A.2 N/A
A.2.2 Conditioning of samples; EL 2132-10 See above Cl. No. A.2 N/A
temperature (°C):
A.2.3 Mounting of samples: EL 2132-11 See above Cl. No. A.2 N/A
A.2.4 Test flame (see IEC 60695-11- EL 2132-12 See above Cl. No. A.2 N/A
4)
Flame A, B or C: See above Cl. No. A.2 N/A

TRF No. BIS_IT/S_IS13252_V1.4

Page 71 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 63 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Fire Safety EL 2132 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
A.2.5 Test procedure EL 2132-13 See above Cl. No. A.2 N/A
A.2.6 Compliance criteria EL 2132-14 See above Cl. No. A.2 N/A
Sample 1 burning time (s): See above Cl. No. A.2 N/A
Sample 2 burning time (s): See above Cl. No. A.2 N/A
Sample 3 burning time (s): See above Cl. No. A.2 N/A
A.2.7 Alternative test acc. To IEC EL 2132-15 See above Cl. No. A.2 N/A
60695-11-5, cl. 5 and 9
Sample 1 burning time (s): See above Cl. No. A.2 N/A
Sample 2 burning time (s): See above Cl. No. A.2 N/A
Sample 3 burning time (s): See above Cl. No. A.2 N/A
A.3 Hot flaming oil test (see 4.6.2) EL 2132-16 No such opening. N/A
A.3.1 Mounting of samples EL 2132-17 See above Cl. No. A.3 N/A
A.3.2 Test procedure EL 2132-18 See above Cl. No. A.3 N/A
A.3.3 Compliance criterion EL 2132-19 See above Cl. No. A.3 N/A

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 20


Total No of applicable Tests = 02
No. of tests for which the sample passed = 02

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 72 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 64 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Insulating Properties EL 2133 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
B ANNEX B, MOTOR TESTS EL 2133-00 P
UNDER ABNORMAL
CONDITIONS (see 4.7.2.2 and
5.3.2)
B.1 General requirements EL 2133-01 See below P
Position: Inside enclosure P
Manufacturer: See table 1.5.1 P
Type: See table 1.5.1 P
Rated values: See table 1.5.1 P
B.2 Test conditions EL 2133-02 Considered P
B.3 Maximum temperatures EL 2133-03 See below Cl. No.B.7.3 P
B.4 Running overload test EL 2133-04 DC motor used in secondary only N/A
B.5 Locked-rotor overload test EL 2133-05 DC motor used in secondary only N/A
Test duration (days): See above B N/A
Electric strength test: test See above B N/A
voltage (V) :
B.6 Running overload test for d.c. EL 2133-06 No such motor N/A
motors in secondary circuits
B.6.1 General EL 2133-07 See above B.6 N/A
B.6.2 Test procedure EL 2133-08 See above B.6 N/A
B.6.3 Alternative test procedure EL 2133-09 See above B.6 N/A
B.6.4 Electric strength test; test EL 2133-10 See above B.6 N/A
voltage (V):
B.7 Locked-rotor overload test for EL 2133-11 See below P
d.c. motors in secondary
circuits
B.7.1 General EL 2133-12 See below Cl. No. B.7.3 P
B.7.2 Test procedure EL 2133-13 Alternative test procedure used N/A
B.7.3 Alternative test procedure EL 2133-14 No ignition of cheesecloth P
B.7.4 Electric strength test; test EL 2133-15 DC motor voltage does not exceed N/A
voltage (V) : 42.4Vpeak or 60Vdc
B.8 Test for motors with capacitors EL 2133-16 No such motor N/A
B.9 Test for three-phase motors EL 2133-17 No such motor N/A
B.10 Test for series motors EL 2133-18 No such motor N/A

TRF No. BIS_IT/S_IS13252_V1.4

Page 73 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 65 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Insulating Properties EL 2133 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
Operating voltage (V) : No such motor N/A

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 19


Total No of applicable Tests = 07
No. of tests for which the sample passed = 07

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 74 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 66 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2134 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
C ANNEX C, TRANSFORMERS EL 2134-00 No transformer used N/A
(see 1.5.4 and 5.3.3) *
Position: See above Cl. No. C N/A
Manufacturer: See above Cl. No. C N/A
Type: See above Cl. No. C N/A
Rated values: See above Cl. No. C N/A
Method of protection: See above Cl. No. C N/A
C.1 Overload test EL 2134-01 See above Cl. No. C N/A
C.2 Insulation EL 2134-02 See above Cl. No. C N/A
Protection from displacement of See above Cl. No. C N/A
windings:

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 02


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 75 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 67 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Insulating Properties EL 2135 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
D ANNEX D, MEASURING EL 2135-00 Class III equipment N/A
INSTRUMENTS FOR TOUCH-
CURRENT TESTS (see 5.1.4)
D.1 Measuring instrument EL 2135-01 See above Cl. No. D N/A
D.2 Alternative measuring EL 2135-02 See above Cl. No. D N/A
instrument

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 03


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 76 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 68 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Thermal Properties EL 2136– V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
E ANNEX E, TEMPERATURE EL2136-00 Class III equipment N/A
RISE OF A WINDING (see
1.4.13)

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 77 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 69 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2137 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
F ANNEX F, MEASUREMENT EL2137-00 Class III equipment N/A
OF CLEARANCES AND
CREEPAGE DISTANCES
(see 2.10 and Annex G)

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed =N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 78 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 70 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical safety EL 2138 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
G ANNEX G, ALTERNATIVE EL 2138-00 Class III equipment N/A
METHOD FOR DETERMINING
MINIMUM CLEARANCES
G.1 Clearances EL 2138-01 See above Cl. No. G N/A
G.1.1 General EL 2138-02 See above Cl. No. G N/A
G.1.2 Summary of the procedure for EL 2138-03 See above Cl. No. G N/A
determining minimum
clearances
G.2 Determination of mains EL 2138-04 See above Cl. No. G N/A
transient voltage (V)
G.2.1 AC Mains supply EL 2138-05 See above Cl. No. G N/A
G.2.2 Earthed d.c. mains supplies EL 2138-06 See above Cl. No. G N/A
G.2.3 Unearthed d.c. mains supplies EL 2138-07 See above Cl. No. G N/A
G.2.4 Battery operation EL 2138-08 See above Cl. No. G N/A
G.3 Determination of EL 2138-09 See above Cl. No. G N/A
telecommunication network
transient voltage (V)
G.4 Determination of required EL 2138-10 See above Cl. No. G N/A
withstand voltage (V)
G.4.1 Mains transients and internal EL 2138-11 See above Cl. No. G N/A
repetitive peaks
G.4.2 Transients from EL 2138-12 See above Cl. No. G N/A
telecommunication networks:
G.4.3 Combination of transients EL 2138-13 See above Cl. No. G N/A
G.4.4 Transients from cable EL 2138-14 See above Cl. No. G N/A
distribution systems
G.5 Measurement of transient EL 2138-15 See above Cl. No. G N/A
voltages (V)
a) Transients from a mains See above Cl. No. G N/A
supply
For an a.c. mains supply See above Cl. No. G N/A
For a d.c. mains supply See above Cl. No. G N/A
b) Transients from a See above Cl. No. G N/A
telecommunication network
G.6 Determination of minimum EL 2138-16 See above Cl. No. G N/A
clearances

TRF No. BIS_IT/S_IS13252_V1.4

Page 79 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 71 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 17


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 80 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 72 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Radiation Safety EL 2139 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
H ANNEX H, IONIZING EL 2139-00 N/A
RADIATION (see 4.3.13)

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 81 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 73 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2140 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
J ANNEX J, TABLE OF EL 2140-00 Class III equipment N/A
ELECTROCHEMICAL
POTENTIALS (see 2.6.5.6) *
Metal(s) used: See above Cl. No. J N/A

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 00


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 82 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 74 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to General Requirement EL 2141 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
K ANNEX K, THERMAL EL 2141-00 No thermal controls used N/A
CONTROLS (see 1.5.3 and
5.3.8)*
K.1 Making and breaking capacity EL 2141-01 See above Cl. No. K N/A
K.2 Thermostat reliability; operating EL 2141-02 See above Cl. No. K N/A
voltage (V) :
K.3 Thermostat endurance test; EL 2141-03 See above Cl. No. K N/A
operating voltage (V) :
K.4 Temperature limiter endurance; EL 2141-04 See above Cl. No. K N/A
operating voltage (V) :
K.5 Thermal cut-out reliability EL 2141-05 See above Cl. No. K N/A
K.6 Stability of operation EL 2141-06 See above Cl. No. K N/A

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 06


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 83 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 75 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to General Requirement EL 2142 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
L ANNEX L, NORMAL LOAD EL 2142-00 In compliance P
CONDITIONS FOR SOME
TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see
1.2.2.1 and 4.5.2) *
L.1 Typewriters* EL 2142-01 See below Cl. No. L.7 N/A
L.2 Adding machines and cash EL 2142-02 See below Cl. No. L.7 N/A
registers*
L.3 Erasers* EL 2142-03 See below Cl. No. L.7 N/A
L.4 Pencil sharpeners* EL 2142-04 See below Cl. No. L.7 N/A
L.5 Duplicators and copy EL 2142-05 See below Cl. No. L.7 N/A
machines*
L.6 Motor-operated files* EL 2142-06 See below Cl. No. L.7 N/A
L.7 Other business equipment* EL 2142-07 See table 1.6.2 P

*- Total number of Requirements to be observed / inspected = 08


Total No of applicable Requirement = 02
No of Requirements for which the sample passed = 02

Total number of tests to be conducted = 00


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 84 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 76 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2143 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
M ANNEX M, CRITERIA FOR EL 2143-00 No telephone ringing signals N/A
TELEPHONE RINGING
SIGNALS (see 2.3.1)
M.1 Introduction* EL 2143-01 See above Cl. No. M N/A
M.2 Method A EL 2143-02 See above Cl. No. M N/A
M.3 Method B EL 2143-03 See above Cl. No. M N/A
M.3.1 Ringing signal EL 2143-04 See above Cl. No. M N/A
M.3.1.1 Frequency (Hz) ......................................................
EL 2143-05 See : above Cl. No. M N/A
M.3.1.2 Voltage (V) .............................................................
EL 2143-06 See : above Cl. No. M N/A
M.3.1.3 Cadence; time (s), voltage (V) ...............................
EL 2143-07 See : above Cl. No. M N/A
M.3.1.4 Single fault current (mA) ........................................
EL 2143-08 See : above Cl. No. M N/A
M.3.2 Tripping device and monitoring EL 2143-09 See above Cl. No. M N/A
voltage ................................................................... :
M.3.2.1 Conditions for use of a tripping EL 2143-10 See above Cl. No. M N/A
device or a monitoring voltage
M.3.2.2 Tripping device EL 2143-11 See above Cl. No. M N/A
M.3.2.3 Monitoring voltage (V) ...........................................
EL 2143-12 See : above Cl. No. M N/A

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted =12


Total No of applicable Tests = 00
No. of tests for which the sample passed =N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 85 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 77 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical safety EL 2144 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
N ANNEX N, IMPULSE TEST EL 2144-00 Class III equipment N/A
GENERATORS (see 1.5.7.2,
1.5.7.3, 2.10.3.9, 6.2.2.1, 7.3.2,
7.4.3 and Clause G.5)
N.1 ITU-T impulse test generators EL 2144-01 See above Cl. No. N N/A
N.2 IEC 60065 impulse test EL 2144-02 See above Cl. No. N N/A
generator

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 03


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 86 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 78 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to General Requirements EL 2145– V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
P ANNEX P, NORMATIVE EL 2145-00 N/A
REFERENCES

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 87 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 79 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to General Requirements EL 2146 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
Q ANNEX Q, Voltage dependent EL 2146-00 VDRs not used N/A
resistors (VDRs) (see 1.5.9.1)
A VDR shall comply with iec See above Cl. No. Q N/A
61051-2, whether a fire enclosure
is provided or not, taking into
account all of the following:
4) ...................................................................... PSee above Cl. No. Q N/A
referred climatic
categories
Lower category temperature:
-10ºC
Upper category temperature:
+85ºC
Duration of damp Test, steady
state test:21 days
b) Maximum continuous voltage: See above Cl. No. Q N/A
Atleast 1,25 times the rated
voltage of the equipment or
Atleast 1,25 times the upper
voltage of the rated voltage range
c) Combination pulse: EL 2146-01 See above Cl. No. Q N/A
d) Body of the VDR shall comply EL 2146-02 See above Cl. No. Q N/A
with Needle flame test according
to IEC 60695-11-5 with the
following test severities:
duration of application of the test
flame: 10 s
after flame time: 5s
[This test is not required if VDR
complies with V-1 CLASS
MATERIAL]
*- Total number of Requirements to be observed / inspected = 01
Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 02


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 88 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 80 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to General Requirement EL 2147– V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
R ANNEX R, EXAMPLES OF EL 2147-00 N/A
REQUIREMENTS FOR
QUALITY CONTROL
PROGRAMMES*
R.1 Minimum separation distances EL 2147-01 N/A
for unpopulated coated printed
boards (see 2.10.6.2)*
R.2 Reduced clearances (see EL 2147-02 N/A
2.10.3)*

*- Total number of Requirements to be observed / inspected = 03


Total No of applicable Requirement = 00
No of Requirements for which the sample passed =N/A

Total number of tests to be conducted = 00


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 89 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 81 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to General Requirement EL 2148 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
S ANNEX S, PROCEDURE FOR EL 2148-00 Class III equipment N/A
IMPULSE TESTING (see
6.2.2.3)*
S.1 Test equipment* EL 2148-01 See above Cl. No. S N/A
S.2 Test procedure* EL 2148-02 See above Cl. No. S N/A
S.3 Examples of waveforms during EL 2148-03 See above Cl. No. S N/A
impulse testing*

*- Total number of Requirements to be observed / inspected = 04


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 00


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 90 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 82 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Protection against Ingress of water EL 2149 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
T ANNEX T, GUIDANCE ON EL 2149-00 IPXX N/A
PROTECTION AGAINST
INGRESS OF WATER
(see 1.1.2)

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 91 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 83 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

EL 2150 – V1.4
Tests relating to Wiring
Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
U ANNEX U, INSULATED EL2150-00 N/A
WINDING WIRES FOR USE
WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
U.1 GENERAL EL2150-01 N/A
U.2 TYPE TESTS EL2150-02 N/A
U.2.1 GENERAL EL2150-03 N/A
U.2.2 ELECTRIC STRENGTH EL2150-04 N/A
U.2.2.1 SOLID ROUND WINDING WIRE EL2150-05 N/A
AND STRANDED WINDING
WIRES
U.2.2.1.1 WIRES WITH NOMINAL EL2150-06 N/A
CONDUCTOR DIAMETER
UPTO AND INCLUDING
0.100MM
U.2.2.1.2 WIRES WITH NOMINAL EL2150-07 N/A
CONDUCTOR DIAMETER
OVER 0.100MM AND
INCLUDING 2.500MM
U.2.2.1.3 WIRES WITH NOMINAL EL2150-08 N/A
CONDUCTOR DIAMETER
OVER 2.500MM
U.2.2.2 SQUARE OR RECTANGULAR EL2150-09 N/A
WIRES
U.2.3 FLEXIBILITY AND ADHERENCE EL2150-10 N/A
U.2.4 HEAT SHOCK EL2150-11 N/A
U.2.5 RETENTION OF ELECTRIC EL2150-12 N/A
STRENGTH AFTER BENDING
U.3 TESTING DURING EL2150-13 N/A
MANUFACTURING
U.3.1 GENERAL EL2150-14 N/A
U.3.2 ROUTINE TESTS EL2150-15 N/A
U.3.3 SAMPLING TEST EL2150-16 N/A

TRF No. BIS_IT/S_IS13252_V1.4

Page 92 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 84 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 17


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 93 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 85 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2151 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
V ANNEX V, AC POWER EL 2151-00 Equipment not directly connected to N/A
DISTRIBUTION SYSTEMS mains
(see 1.6.1) *
V.1 Introduction* EL 2151-01 See above Cl. No. V N/A
V.2 TN power distribution systems EL 2151-02 See above Cl. No. V N/A
V.3 TT Power Distribution systems EL 2151-03 See above Cl. No. V N/A
V.4 IT Power Distribution systems EL 2151-04 See above Cl. No. V N/A

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 03


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 94 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 86 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2152 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
W ANNEX W, SUMMATION OF EL 2152-00 Class III equipment N/A
TOUCH CURRENTS *
W.1 Touch current from electronic EL 2152-01 See above Cl. No. W N/A
circuits*
W.1.1 Floating circuits* EL 2152-02 See above Cl. No. W N/A
W.1.2 Earthed circuits* EL 2152-03 See above Cl. No. W N/A
W.2 Interconnection of several EL 2152-04 See above Cl. No. W N/A
equipments*
W.2.1 Isolation* EL 2152-05 See above Cl. No. W N/A
W.2.2 Common return, isolated from EL 2152-06 See above Cl. No. W N/A
earth*
W.2.3 Common return, connected to EL 2152-07 See above Cl. No. W N/A
protective earth*

*- Total number of Requirements to be observed / inspected = 08


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 00


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 95 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 87 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2153– V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
X ANNEX X, MAXIMUM EL 2153-00 Class III equipment N/A
HEATING EFFECT IN
TRANSFORMER TESTS
(see clause C.1)*
X.1 Determination of maximum EL 2153-01 See above Cl. No. X N/A
input current*
X.2 Overload test procedure* EL 2153-02 See above Cl. No. X N/A

*- Total number of Requirements to be observed / inspected = 03


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 00


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 96 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 88 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Radiation Safety EL 2154– V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
Y ANNEX Y, ULTRAVIOLET EL 2154-00 No ultraviolet light N/A
LIGHT CONDITIONING TEST
(see 4.3.13.3)
Y.1 EL 2154-01 See
Test apparatus ....................................................... : above Cl. No. Y N/A
Y.2 EL 2154-02 See
Mounting of test samples ...................................... : above Cl. No. Y N/A
Y.3 Carbon-arc light-exposure EL 2154-03 See above Cl. No. Y N/A
apparatus ............................................................... :
Y.4 Xenon-arc light exposure EL 2154-04 See above Cl. No. Y N/A
apparatus ............................................................... :

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 05


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 97 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 89 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2155– V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
Z ANNEX Z, OVERVOLTAGE EL 2155-00 Class III Equipment N/A
CATEGORIES (see 2.10.3.2
and Clause G.2)*

*- Total number of Requirements to be observed / inspected = 01


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 00


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 98 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 90 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Mechanical Properties EL 2156 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
AA ANNEX AA, MANDREL TEST EL 2156-00 N/A
(see 2.10.5.8)

*- Total number of Requirements to be observed / inspected = 00


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 01


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 99 of 110
Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 91 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Electrical Safety EL 2158 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
CC Evaluation of integrated circuit EL 2158-00 No IC as current limiters are used N/A
(IC) current limiters*
CC.1 Integrated circuit (IC) current EL 2158-01 See above Cl. No. CC N/A
limiters*
CC.2 Test program 1 EL 2158-02 See above Cl. No. CC N/A
CC.3 Test program 2 EL 2158-03 See above Cl. No. CC N/A
CC.4 Test program 3 EL 2158-04 See above Cl. No. CC N/A
CC.5 Compliance EL 2158-05 See above Cl. No. CC N/A

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 04


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 100 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 92 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Mechanical Properties EL 2159 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
DD Requirements for the mounting EL 2159-00 Not a rack mounted equipment N/A
means of rack-mounted
equipment*
DD.1 General See above Cl. No. DD N/A
DD.2 Mechanical strength test, EL 2159-01 See above Cl. No. DD N/A
variable N………………..:
DD.3 Mechanical strength test, 250N, EL 2159-02 See above Cl. No. DD N/A
including end stops………..:
DD.4 Compliance*………………….: EL 2159-03 See above Cl. No. DD N/A

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 02


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 101 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 93 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Tests relating to Mechanical Properties EL 2160 – V1.4


Cl. No. Test / Requirement name Test Code Test result/ observation Verdict
EE ANNEX EE, Household and EL 2160-00 No such equipment N/A
home/office document/media
shredders
EE.1 General See above Cl. No. EE N/A
EE.2 Markings and instructions* EL 2160-01 See above Cl. No. EE N/A
Use of markings or See above Cl. No. EE N/A
symbols*…………………………
:
Information of user instructions, See above Cl. No. EE N/A
maintenance and/or servicing
instructions*……………………
……:
EE.3 Inadvertent reactivation EL 2160-02 See above Cl. No. EE N/A
test…………………………:
EE.4 Disconnection of power to EL 2160-03 See above Cl. No. EE N/A
hazardous moving parts*
Use of markings or See above Cl. No. EE N/A
symbols*………………………:
EE.5 Protection against hazardous See above Cl. No. EE N/A
moving parts
Test with test finger (Figure 2A) EL 2160-04 See above Cl. No. EE N/A
……………………:
Test with wedge probe (Figure EL 2160-05 See above Cl. No. EE N/A
EE1 and EE2) ……:

*- Total number of Requirements to be observed / inspected = 02


Total No of applicable Requirement = 00
No of Requirements for which the sample passed = N/A

Total number of tests to be conducted = 04


Total No of applicable Tests = 00
No. of tests for which the sample passed = N/A

Certificate: It is certified that the above tests were performed and found to be passing/failing in the
requirement tested.

...............................................................................
(Approving Authority)

TRF No. BIS_IT/S_IS13252_V1.4

Page 102 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 94 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

1.5.1 TABLE: List of components P


Object/part no. Manufacturer/ Type/model Technical data Standard Mark(s) of
trademark conformity1
Plastic FORMOSA AG15E1 HB75, 85˚C UL 94 UL E162823
Enclosure CHEMICALS & Minimum
(Flammability test
FIBRE CORP thickness:
equivalent to IEC
PLASTICS DIV 1.5mm
60695-11-10 )
Acrylonitrile
Butadiene
Styrene (ABS)
Alternate FORMOSA AG15A1, HB75, 85˚C UL 94 UL E162823
CHEMICALS & Minimum
AG15E0, (Flammability test
FIBRE CORP thickness:
AG15A0 equivalent to IEC
PLASTICS DIV 1.5mm
60695-11-10 )
Acrylonitrile
Butadiene
Styrene (ABS)
PCB SHENZHEN FX-M 130°C, V-0 UL 796 UL E302652
FUXIANG (No equivalent IEC
TECHNOLOGY standard)
CO LTD

CM109- Test report by


CIS module ASIA TECH IMAGE CS605, 3.3-5.0 Vdc, IEC 62471:2006 TUVSUD
INC. CM109- Exempt Group (No:6110614004
CSA05 01)

Vitai Technology M15SP- IS 13252 (Part 1):


Stepping 5.0 V/phase Tested Within
Co., Ltd. WW28 2010 + A1: 2013 +
motor 80 mA/phases A2: 2015 Equipment

Supplementary information:
1. Evidences provided by the manufacturer for the listed components are verified by us and the
evidences are conforming to the requirments of the relevent standerd.

TRF No. BIS_IT/S_IS13252_V1.4

Page 103 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 95 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

1.6.2 TABLE: Electrical data (in normal conditions) P


U (V) I (A) I rated (A) P (W) Fuse # I fuse (A) Condition/status
5 0.265 0.5 1.325 -- -- Maximum normal load
Supplementary information: Nil

2.1.1.5 TABLE: Energy hazard measurement P


Voltage (rated) Current (rated) Voltage (max.) Current (max.) VA (max.)
(V) (A) (V) (A) (VA)
-- -- -- -- --
Supplementary information: Powered by SELV only

2.1.1.7 TABLE: Discharge test N/A


Condition  calculated  measured t u→ 0V Comments
(s) (s) (s)

-- -- -- -- --

Supplementary information: Class III equipment

2.2.2 TABLE: SELV measurement (under normal conditions) P


Transformer Location Voltage (max.) (V) Voltage Limitation
Component
V peak V d.c.
-- -- -- -- --

Supplementary information: Powered by SELV only

2.2.3 TABLE: SELV measurement (under fault conditions) P


Location Voltage (max.) (V) Comments
-- -- --

Supplementary information: Powered by SELV only

2.4.2 TABLE: Limited current circuit measurement N/A


Location Voltage Current Freq. Limit Comments
(V) (mA) (kHz) (mA)
-- -- -- -- -- --

Supplementary information: No limited current circuit

TRF No. BIS_IT/S_IS13252_V1.4

Page 104 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 96 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

2.5 TABLE: Limited power source measurement N/A


Limits Measured Verdict
According to Table 2B/2C (normal condition)
current (in A) -- -- --
apparent power (in VA) -- -- --
According to Table 2B/2C (single fault condition)
current (in A) -- -- --
apparent power (in VA) -- -- --
Supplementary information:Nil

2.6.3.4 TABLE: Resistance of earthing measurement N/A


Location Resistance measured (m) Comments
-- -- --

Supplementary information: Tested current 32A.

<OR>
2.6.3.4 TABLE: Resistance of earthing measurement N/A
Location Voltage drop (V) Comments
-- -- --

Supplementary information: Tested current 40A.

2.10.2 Table: Working voltage measurement N/A


Location RMS voltage (V) Peak voltage (V) Comments
-- -- -- --

Supplementary information:Class III equipment

2.10.3 and 2.10.4 TABLE: Clearance and creepage distance measurements N/A
Clearance (cl) and creepage U peak U r.m.s. Required cl Required cr
distance (cr) at/of/between: (V) (V) cl (mm) (mm) cr (mm) (mm)
Functional:
-- -- -- -- -- -- --

Basic / supplementary:
-- -- -- -- -- -- --

Reinforced:
-- -- -- -- -- -- --

Supplementary information: Class III equipment

TRF No. BIS_IT/S_IS13252_V1.4

Page 105 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 97 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

2.10.5 TABLE: Distance through insulation measurements N/A


Distance through insulation (DTI) at/of: U peak U r.m.s. Test Required DTI
(V) (V) voltage DTI (mm)
(V) (mm)
Basic:
-- -- -- -- -- --

Supplementary:
-- -- -- -- -- --

Reinforced:
-- -- -- -- -- --

Supplementary information: No such insulation

4.3.8 TABLE: Batteries N/A


The tests of 4.3.8 are applicable only when appropriate battery No battery used N/A
data is not available
Is it possible to install the battery in a reverse polarity position? See above N/A
Non-rechargeable batteries Rechargeable batteries
Discharging Un- Charging Discharging Reversed charging
intentional
Meas. Manuf. charging Meas. Manuf. Meas. Manuf. Meas. Manuf.
Current Specs. Current Specs. Current Specs. Current Specs.
Max. -- -- -- -- -- -- -- -- --
current
during
normal
condition
Max. -- -- -- -- -- -- -- -- --
current
during
fault
condition

Test results: Verdict


- Chemical leaks -- --

- Explosion of the battery -- --

- Emission of flame or expulsion of molten metal -- --

- Electric strength tests of equipment after completion of tests -- --

Supplementary information: Battery not used

TRF No. BIS_IT/S_IS13252_V1.4

Page 106 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 98 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

4.5 TABLE: Temperature rise measurements P


Temperatures were measured according cl. 1.4.5. Test in condition A and B at continuous normal operation
as for power input measurements of table 1.6.2 resulted in highest temperature values.
Temperatures are calculated according cl. 1.4.12.3 with regard to the maximum ambient operation
temperature of 40°C (Tma), as specified by the manufacturer.
Test voltage(s) (V): A: 5Vdc B: --
tamb1 (°C): -- A: 26 B: -- tamb2 (°C): A: 26 B: --
Temperature of part/at: Measured temperature Calculated Allowed
(measured with thermocouples) rise at Tamb temperature at Tma Tmax (°C)
A B A B
dT (K) dT (K) T (°C) T (°C)
Plastic enclosure 02 -- 42 -- 95
PCB 04 -- 44 -- 130
Stepper Motor 09 -- 49 -- 90
Supplementary information: Nil
Temperatures measured with winding resistance method: Not used
temperature T of winding: (V) R1 (  ) R2 (  ) T (C) allowed insulation
(winding resistance method) Tmax (C) class
-- -- -- -- -- -- --
Supplementary information:Nil

4.5.5 TABLE: Ball pressure test of thermoplastic parts N/A


Allowed impression diameter (mm) .................. :  2 mm ⎯
Part Test temperature Impression diameter
(°C) (mm)
-- -- --
Supplementary information: Class III equipment powered by SELV only

4.6.1, 4.6.2 Table: Enclosure opening measurements N/A


Location Size (mm) Comments
-- -- --
Supplementary information: No Such Opening

4.7 Table: Resistance to fire P


Part Manufacturer of Type of material Thickness Flammability Evidence
material (mm) class
Plastic Enclosure FORMOSA Acrylonitrile 2.067 HB75 TEST
CHEMICALS & Butadiene Styrene PERFOR
FIBRE CORP (ABS) MED ON
PLASTICS DIV 550˚C
Supplementary information: Nil

TRF No. BIS_IT/S_IS13252_V1.4

Page 107 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 99 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

5.1.6 TABLE: Touch current and protective conductor current measurement N/A
Test voltage (V) ....................................... : AC ……. V, ………Hz ⎯
Measurement location Polarity (normal) Polarity (reverse) [mA] Limit Comments
[mA] (mA)
(Terminal A connected to...) Switch: Switch: Switch: Switch:
ON OFF ON OFF
Earth terminal -- -- -- -- -- --
("e" = open)
Operating Panel -- -- -- -- -- --
("e" = close)
Supplementary information: Class III equipment

5.2 TABLE: Electric strength tests, impulse tests and voltage surge tests N/A
Test voltage applied between: Voltage shape Test voltage Breakdown
(AC, DC, (V) Yes / No
impulse, surge)
Functional:
-- -- -- --

Basic / supplementary:
-- -- -- --

Reinforced:
-- -- -- --
Supplementary information: Class III equipment

5.3 TABLE: Fault condition tests P


Ambient temperature (°C) ...................................... : 27°C P
Power source for EUT: Manufacturer, model/type, See table 1.5.1 P
output rating ........................................................... :
Component Fault Supply Test Fuse # Fuse Observation
No. voltage time current
(V) (A)
C20 Short circuit 5Vdc 2min. -- -- Unit shutdown immediately
Result: No fire, No hazardous

Supplementary information: Nil

TRF No. BIS_IT/S_IS13252_V1.4

Page 108 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 100 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

C.2 TABLE: Insulation of transformers N/A


Transformer part name ........................... : No Transformer used N/A
Manufacturer ........................................... : See above N/A
Type ........................................................ : See above N/A
Clearance (cl) and creepage U peak U r.m.s. Required cl Required cr
distance (cr) at/of/between: (V) (V) cl (mm) (mm) cr (mm) (mm)
Primary /input winding and -- -- -- --
secondary/output winding
(internal)
Primary/input winding and core -- -- -- --
(internal)
Secondary/output winding and -- -- -- --
core (internal)
Primary/input part and -- -- -- --
secondary/output part
(external)
Primary/input part and core -- -- -- --
(external)
Primary/input part and -- -- -- --
secondary/output winding
(external)
Secondary/output part and -- -- -- --
core (external)
Secondary/output part and -- -- -- --
primary/input winding
(external)
Description of design:
(a) Bobbin
Primary/input pins ..................................................... : --

Secondary/output pins.............................................. : --

Material (manufacturer, type, ratings) ...................... : --

Thickness (mm) ........................................................ : --

(b) General
Please insert here a description of the transformer design describing:
Supplementary information:Transformer not used

TRF No. BIS_IT/S_IS13252_V1.4

Page 109 of 110


Report No.: SC24EPF02900_1 IS 13252 (Part 1): 2010 + A1: 2013 + A2: 2015 / Page 101 of 101
Dated: 19/03/2024 IEC 60950-1: 2005 + A1:2009 + A2: 2013 ULR- B-TL110424000000297

Attachment: 1

PHOTOGRAPHS

External View 1 External View 2

Internal View

PCB View 1 PCB View 2

***END REPORT***