Unica: Catalogue 2016
Unica: Catalogue 2016
Catalogue 2016
P113206
           schneider-electric.com/proURL
                                                            www.schneider-electric.com
P113219
                                                                 P84932
                                      P86303
                                                    Appearance
                                                    counts
          Unica Quadro                          Unica Allegro            Unica Colors            Unica Basic
P104530
P86338
P91459
P86055
Contents
Presentation
Unica ranges overview  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .              6
Solutions for comfort, communication, safety
and energy-saving  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .            8
Unica for KNX system  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .              16
Comprehensive functionalities  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                 22
Two installation architectures  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                24
The modularity system  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .             26
Technical benefits .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .           28
Unica Class, Top	                                                                                                    	
Presentation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .        30
Inserts .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .    32
Wireless inserts  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .         56
KNX inserts .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .      59
Fixing frames and boxes  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .              61
Unica Class aesthetics and cover frames .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                          62
Unica Top aesthetics and cover frames .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                         72
Unica Plus, Quadro, Allegro, Colors, Basic	
Presentation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  82
Inserts .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  86
Wireless inserts  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 113
KNX inserts .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 116
Fixing frames and boxes  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 118
Unica Plus aesthetics and cover frames  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 120
Unica Quadro aesthetics and cover frames .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 132
Unica Allegro aesthetics and cover frames .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 138
Unica Colors aesthetics and cover frames  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 144
Unica Basic aesthetics and cover frames .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 150
Technical information	
(excluding Unica Wireless and KNX)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 155
Unica Wireless	
Presentation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 214
Scenarios .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 218
Quick-selection guide .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 222
Technical information .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 224
Unica KNX	
Presentation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 238
Quick-selection guide .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 242
Technical information .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 243
Reference numbers  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 246
Version : 8.0 - 12 décembre 2016
ISC01064EN
                                                                                                                                                 5
                                                                                                        www.schneider-electric.com
                                                                                                        P113198
                                                                                                                  Slate/Aluminium
                                                                                                        P113195
P113204
Apple aluminium/Graphite
          Unica Class
          Modern life makes us long for nature, with the original, true and pure building blocks of our existence.
          Like the comforting sight of clear ocean waves, the dust from ochrecolored soil. Or the unexpected chilly
          hardness from a jagged piece of rock…
          Unica Class cover frames brings the roughness of minerals, the beauty of crystal transparence and many
          other sensations into your life. Open your door and let nature into your home!
          Unica Top
                                                                                   A Unica Top choice is what it sounds like.
                                                                                   A top choice! Concern about detail is
                                                                                   necessary to make a perfect result.
                                                                                   Unica Top is made to last, and to make
                                                                                   a lasting impression. Don’t miss out on
                                                                                   the distinction. Find what exclusively
                                                                                   matches you!
                                                                          P86022
P104143
P86324
                                              Unica Plus
                                              Includes that little extra that makes a difference.
                                              Satisfying high demands concerning longevity,
                                              functionality and cared design. A choice signalling
                                              exclusiveness – carrying the impression and comfort of
                                              your home to new levels.
P90191
P84929
                                                                          P97412
                                              Unica Quadro
                                              The trendy choice. Provides your home with a young,
                                              fresh, minimalisticly modern look. In sparkling red or
                                              aesthetic silver. Make a statement: Every spot in your
                                              home is worth design attention.
P105762
P104523
                                                                          P104529
                                              Unica Allegro
                                              A temptingly multifunctional and prominent choice.
                                              In a range of metallised colours to mix and match.
                                              Will blend with almost any style. Has the qualities
                                              and aesthetics of a designer’s best friend.
P90177
                                                                          P86338
                                     P86332
                                              Unica Colors
                                              Give each room its own personality. Match your style
                                              and interior, as often as you please. A real versatile
                                              choice, with several opportunities.
P90200
P84966
P91461
                                              Unica Basic
                                              A choice clearly above the design of the mainstream
                                              selection. With a sober, timeless stylish expression,
                                              pointing out that you have high standards and care
                                              about what your home looks like.
P90180
P84952
P86055
                                                                                                                                                                                        P105663
              saving.
                                                   Living-room
                                                   Weekly programmable thermostat
                                                   Have your home at the right temperature every time. Saves energy – and keeps you comfortable!
                                                   Weekly programmable timer
                                                   Will save an unexpected amount of energy and prolong the lifetime of your entertainment system.
                                                   Loudspeaker socket
    P105650
                                                   Bedroom
                                                   Save the energy – with
                                                   enhanced comfort
                                                   Prefer a cool bedroom at night?
                                                   The thermostat adds power
                                                   only when necessary.
    P105651
                                                   Wireless comfort
                                                   With Unica remote control
              Wake-up clock                        or a wireless switch beside
                                                   the bed you are in charge
                                                   from the pillow.
                                                   More Unica Top in the
                                                   bedroom
                                                   Wake-up clock. Light dimmer.
  P104878
                                                   Weather station. Roller-blind
              Remote control                       control.
                                                   Bathroom
                                                   Weekly programmable thermostat
                                                                                                                                           P105346
                                                   To have the home at the right temperature every time, optimizing the energy.
                                                   Signal lamp
                                                   If this room is occupied – you will know.
                                                   Cord push-button
    P105652
                                            Staircase                                                                               Garage
                                            Time delay switch                                                                       Time delay switch
                                            For areas where you pass                                                                For areas where you pass through. Will make sure the light is only on
                                            through. Truly energy-saving will                                                       for a short time.
                                            make sure the light is only on
                                            for a short time,                                                                       Basic thermostat
                                            no need to think about switching                                                        One of the best places to save energy.
 P105653
                                                                                P124834
                                            off. Can easily be combined                                                             A precise control of temperature, without significant drops or
                                            with a push-button.                                                                     increases.
           Time delay switch                                                              Switch with blue locator lamp             IP44/IP55 covers or surface boxes
                                                                                                                                    For extra safety and protection using electric equipment.
                                                                                                                                    Switch with blue locator lamp
                                                                                                                                    Blue lamp. Always on.
                                            Kitchen                                                                                 Flood and gas detector
                                                                                                                                    Protect your home against flooding and gas leakage.
                                            Weekly programmable thermostat
                                            Let the heart of your home be a warm kitchen. But not too warm!
                                            Weekly programmable timer.
                                            Program the working time of some loads. Saves energy!
P105654
                                            Double-pole switch
                                            Double electrical safety. Isolate your devices completely
                                            from the installation. Extra important in a kitchen.
           Rotary dimmer
                                            High rating switch
                                                                                                                                                                       P105651
                                            Need to run high amp loads at the same time?
                                            Without blowing your fuse (or the kitchen fuse).
                                                                                                                                                                                 Weekly programmable timer
                                            Alarm-clock
                                            Clock- and alarm function.
                                            Dimmer
                                            Create lighting ambiances, save energy and money.
                                                                                                                                                                                 Laundry
                                                                                                                                                                                 Weekly programmable timer.
                                                                                                                                                                                 Program the working time
                                                                                                                                                                                 of some loads. Saves energy!
                                                                                                                                                                                 And makes sure you are not
                                                                                                                                                                                 leaving appliances turned on
                                                                                                                                                                                 by mistake.
                                                                                                                                                                                 Basic thermostat
                                                                                                                                                                                 One of the best places to save
                                                                                                                                                                                 energy. A precise control of
                                                                                                                                                                                 temperature, without significant
                                                                                                                                                                                 drops or increases.
                                                                                                                                                                                 IP44/IP55 covers or surface
                                                                                                                                                                                 boxes
                                                                                                                                                                                 For extra safety and protection
                                                                                                                                                                                 using electrical equipment.
P105656
Roller-blind switch
                                                                                                                                                                                 Home office
                                                                                                                                                                                 Weekly programmable
                                                                                                                                                                                 thermostat
                                                                                                                                                                                 To have the home at the right
                                                                                                                                                                                 temperature every time is
                                                                                                                                                                                 comfortable and it also optimizes
                                                                                                                                                                                 the energy.
                                                                                                                                                                                 Wireless comfort
                                                                                                                          P105657
Comfort
                                         Thermostat                                         Roller-blind
                                         To get the right temperature                       Roller-blind command in the
                                         at home, to save energy                            same cover frame and finish
                                         and money.                                         as the rest of the wiring
                                         Regulation at finger tips.                         devices. With Unica wireless
                                         Clear indication.                                  you can centralize the
                                                                                            command
                                                                                            and close all shutters
                                                                                            at the same time.
P116587
                                                                            P116582
                                         Movement and presence                              Rotary dimmer
                                         detector                                           Create light ambiances as you
                                         The light when you need it                         want them. Saves energy,
                                         without looking for switches.                      and money.
                                         Good comfort for children,
                                         when people wake up at night.
                                         Saves energy and money.
P116583
P116584
P116586
           8
P10487
P104988
P104154
Communication
Stay
                                                                     TV-SAT socket-outlet
                                                                     Main standards available.
                                                                     Different types of gain loss
                                                                     and installation habits.
connected
                                                        P116589
                                                                     RJ45 data socket
Real-time communication, sharing and distributed                     Main standards available.
                                                                     Compatible with main
on-demand entertainment are a natural part of your                   connectors.
life. The demands of effective data transfers push                   Full range of infraplus and
                                                                     LexCom data sockets.
things
forward at an incredible speed as the connected
                                                        P116588
community grows.
                                                                                   P104155
P113237
P104160
P105647
P105742
          Your reliable
                                                                                         Emergency light
                                                                                         To get some light in case
                                                                                         of power failure, it has a
                                                                                         battery inside. Suitable in
                                                                                         stairs for instance
          guard
                                                                                         or corridors.
                                                                         P116593
                                                                                         Shuttered socket-outlet
                                                                                         Safety for children.
                                                                                         Also available with a hinged
          Who looks after your home when you’re on holiday?                              flap.
          Your friends and family? Well, in a former life maybe.
          Nowadays your home looks after itself, with the use
          of Unica Top weekly programmable thermostats
          and timers. Of course electricity in itself is a powerful
                                                                         P116591
P113236
P113 394
P104153
P129480
Wireless comfort
Unica Wireless is a range of wireless products which use radio technology (RF)
to exchange information. The products are highly suitable for refurbishment
work in residential and small building environments without damaging the
walls.
They make it considerably easier and far more pleasant to control lighting
and roller blinds in the home. They are simple to install and program.
P105346
P105421
                                                        Control the lighting and roller blinds in each room by grouping all
                                                        the controls together in one place and duplicating them on
                                                        a remote control.
                                                        ●● Replace the existing switches (light, blinds) by wireless
                                                        combined modules.
                                                        ●● Stick battery-powered push-buttons in convenient places.
                                                        ●● Add a remote control containing the main functions.
                                                        ●● Link them by simple programming.
                                                                                                                                                                                                                  P104970
                                                                                                                                               P104970
                                                                                                                                                                               Receivers
                                                                                                                                                                               Receivers control the load
                                                                                                                                                                               that is plugged to them
                                                                                                                                                                               (table lamp, ceiling lamp, etc.)
                                                                                                                                                                               and are controlled by the
                                                                                                Combined modules
                                                                                                                                                                               emitters.
                                                                                                They are connected instead of the existing switches.
                                                                                                The key is used for local control; when a second key is mounted it
                                                                                                                                                                     P105580
P105522
                                                                                          P105576
P105566
P105586
          Unica
          for KNX system
P105927
          Intelligent
          and good looking home
P117500
              Connect Unica
              to your KNX system!
                                                                                               Reading in your favourite armchair in the evening, watching
    P117503
                                             Push-button                                                            IR push-button
    P119163
P119165
P119164
                                                                                                                    • Presence-dependent room
                                                                                                                    heating.
                                                                                                                    • Heat is supplied
                                                                                                                    automatically at the exact time
                                                                                                                    required and individually via
                                                                                                                    controllable room temperature
                                                                                                                    control units. No need to turn
P105932
         Comprehensive
         functionalities
         Imagine every necessary technical function and appliance that you would wish
         to be available in your home. The Unica range will most certainly cover every
         corner of those needs. And be assured, under the attractive surface, every
         Unica product offers a quality construction. So please, pay a moment of
         attention to our Unica State Of The Art “Outletology” Chart. Make your choices,
         and get ready to plug and play.
P86156
                                                                            P85908
     P85923
                                                                            P85914
     P85910
P90317
                                                                                                             P85949
                             Switch with blue locator lamp                      Key card switch                            Indicator lamp, orange
                                                                      P85952
P85957
                                                                                                             P85918
                             Push-button with bell symbol                       4-position switch                          Indicator lamp, white
                             and blue locator lamp
                                                                                                             P85920
P85960
P85909
                                                                                                             P90319
P85946
P85911
                             Roller-blind                                       Buzzer
                                                                                                                           Wake-up clock
P85905
P85912
P104699
P85913
P85917
P104679
P85958
     Two installation
     architectures
     Modular universal
    P85994
P84927
                                                                                              P84560
P101831
                                                                                                                                                             P84435
                                                         P84434
                                                                                             P84436
P84434
                                                                  Zamak without claws                  Zamak with short                   Zamak with long             Zamak fixing
                                                                                                       fixed claws                        fixed claws                 frame using
                                                                                                                                                                      accessory
             P84438
P84439
P87447
P87448
                                                                                                                    P104534
                                                         P87449
           Modular multifunctional
  P85995
                                                                                       P101732
                                              Flush modular boxes                                                                             Surface modular boxes
                                              3, 4 and 6 modules.                                                                             Surface box for 3 and 4
                                                                                                                                              modules.
                                                        Centralization
                                                                              P84576
                                                        2 x 4 modules,
                                                        2 x 6 modules .
                                              Multifunction aesthetic
                                              cover frames
                                              Cover frames for flush
                                              or surface installations.
                                                                                                                                   P87457
                                                                                       P87456
                                                                              P87455
 P87456
P87458
                                                                                       P93147
                                                                              P87471
P87472
P104971
                                                                                                                                    Multigang aesthetics:
                                                                                                                                    The perfect aesthetic
                                                                                                                                    complement for the
                                                                                                                                    functionality of Unica.
                                                                                                                                    Centralization:
                                                                                                                                    Centralization cover frame,
 Limit your stock:                                     Adaptation to the                                                            2 x 4 or 2 x 6 modules,
 In the Unica Quadro,                                  surrounding space:                                                           with outlets.
 Unica Colors and Unica                                The cover frames of Unica
 Basic ranges, the same                                Quadro, Unica Colors and
 cover frames can be                                   Unica Basic can be fitted
 fitted either vertically                              in whatever way suits the
                                                                                   P105805
                            P105803
P105802
rectangular box.
Installations in detail
Many years of research
and experience have
enabled us to produce
one of the best fixing
frames on the market,
combining ruggedness
and corrosion
                                                                                                                                                                     P85894
                                   P86161
                                                                                                P105792
                                   P85893
                                                                                                          No sharp edges:
                                                       Long fixed claws                                   Manufactured in zamak, the fixing frame is rugged and
                                                                                                          corrosion resistant. As it is not die-cut, there are no sharp
                                                                                                          edges.
 P105792
P85892
Always straight:
Easier to align, with a straight
supporting surface that makes                          Accessory short claws with
                                                                                              P105793
                                                                                                                                                                                                  P105792
it easy to use a level.                                plastic protection.
Aesthetics in detail
The final look of an
installation does not
depend just on the colour
and design of the visible
parts.
                                    P105795, P105796
                                                       The gloss finish of the insert and cover                                                                                    Fixing systems suited to all
                                                       frames makes them easy to clean.                                                                                            types of cover frames:
                                                       Just wipe with a cloth and they look as                                                                                     In the case of rectangular
                                                       good as new. A cloth is also perfect for                                                                                    cover frames, the fixing system
                                                       cleaning the Unica Top wood and metal                                                                                       used to fit the frame onto the
                                                       frames.                                                                                                                     fixing frame is different.
               05
                  79
                    8                                                                                                                                                              The greater fixing strength
             P1
                                                                                                                                                                                   needed is achieved by using
                                                                                                                                                                                   cylindrical ratchet-type anchor-
                                                                                                                                                                                   pins rather than flat ones.
         Technical benefits
         Switches in detail
         Reduce
         installation time
                                         P127279
                                                                                                                                P138698
         by up to 20%
                                                                                                                                                                    P101742
         The overall aim of the new                                                                                                                                           In both 10 A (grey) and 16 A
         Unica wiring devices is to                                                                                                                                           (black) switches the terminal
         simplify the installer’s job.                                                                                                                                        connection system is by
         To achieve this we have                                                                                                                                              screws.
         worked particularly on all
         the tiny details of install-              Screwless terminals with
         ing our control devices.                  ergonomics release buttons
                                                                                          P127272
                                                                                                                                                                    P101745
                                                   for 1.5 to 2.5 mm2 for rigid
                                                   and flexible wire.
         Socket-outlets in detail
         Based on our customers’
         experience as installers,
         gathered through
         exhaustive market
                                                                                                                                                                 P109715
         research, we have
         developed the fitting                                                                                                                                                Available in screwless version
         and safety features                                                                                                                                                  with easy color code for
                                                                                                                                                                              cabling.
         of our socket-outlets
         to match them to ever
                                         P85868
                                                   eliminating a step in
                                                   installation.
                                                                                                                                                                              Pilot lamp version:
                                                                                                                                                                              LED is connected as soon
                                                   Childproof:                                                                                                                as the centerplate is clipped.
P85869
                                                                                                                                                                 P109717
P85870
                                                                                               P121608
and data transmission,
more than meeting the
requirements of cat 5e                                                                                    Automatic 360° earthing
and cat 6.
                                        P121600
                                                                                                P121609
Ease of connection:
Cables can be connected                           Reliable connections:
without tools to the RJ45                         Internal contacts: IDC                                  Integrated earth-drain
socket by hand. Faster cable                      technology to make the                                  contact to provide
termination by clipping.                          connection with the copper                              double earthing
                                                  wire easier.
Universal connection:
Complies with all connection
conventions: EIA/TIA 568A,                        Cable organizer:
568B.                                             Easy organization of cables
                                                  and simultaneous connection
                                                  of the 4 pairs of cables.
                                                                                                                                                               P105808
A wide range:                                     Cat 5e: green, cat 6: blue
RJ45 sockets are available for                    shutter cap colour. Using
unshielded, foiled and shielded                   the organizer ensures the
cables meeting the range
                                                                                                   P121603
                                                                                                                                                                                     P105811
a smart bridle:                                   continuity of the installation.                  according to the same system.
Despite being compact in size,                                                                     Dark blue for Cat6A, Light
the connector has enough                                                                           blue for Cat6 and green for                             Dust-protection shutter
room inside for your work.                                                                         Cat5e.
Both space and functions
are designed to ease your
installation.
Electronic
inserts
                                                                                                                                                                                 P105813
P85881
in detail
                                     P124781
Unica Class
Unica Top
          ISC01064EN
          Unica Class, Top                                                                               www.schneider-electric.com
Inserts
                                    	Controls
                                    	             10 AX – 250 V AC switches
                                                  10 AX one-way screwless terminals        10 AX one-way screw terminals
P84010
P83981
P84214
P84030
                                    	             16 AX – 250 V AC switches
P84272
P84235
P138657
MGU3.262.12 MGU3.162.12
Inserts
P83983
P84216
P83991
P84222
Inserts
                                                     10 A – 250 V AC push-buttons
                                                     10 A screwless terminals                     10 A screw terminals
P84019
P83993
P84228
P83999
P84229
P83998
Inserts
                                                                                    10 A – 12 V AC push-buttons
                                                                                    10 A screwless terminals with bell symbol      10 A screwless terminals with illuminated
P103833
P103834
label holder
P88789
                                                                      Colour          2 modules
                                                                        aluminium   MGU3.701.30
          MGU3.701.30	MGU3.701.12                                       graphite    MGU3.701.12
P84334
                                                                      Colour          2 modules
                                                                        aluminium   MGU3.579.30
                                                                        graphite    MGU3.579.12
          MGU3.579.30	                               MGU3.579.12
                                                                      	             Replacement lamps
                                                                      	             LED for 250 V AC switches and push-buttons
                                                                      	             with locator/indicator lamp
P127268
P127267
                                                                      Colour
                                                                        amber       MGU0.825.AL                                    MGU0.822.AL
          MGU0.825.AL                      MGU0.825.AZL                 blue        MGU0.825.AZL                                   MGU0.822.AZL
                                                                                    For switches and push-buttons with screwless   ●● Before November 2011, for all switches and
P86075
P86076
                                                                      Colour
                                                                        yellow      MGU0.823.AM
MGU0.823.AM
Inserts
                                                    	                Specialized controls
                                                    	                Mechanisms for roller blinds
                                                                     10 A switch screwless                           10 A push-button screwless
P84028
P84260
P138653
P138653
P127851
                                                    Colour             2 modules
                                                      aluminium      MGU3.203.30VMC
          MGU3.203.30VMC	MGU3.203.12VMC               graphite       MGU3.203.12VMC
P127862
P127861
                                                    Colour             2 modules
                                                      aluminium      MGU3.214.30
          MGU3.214.30	MGU3.214.12                     graphite       MGU3.214.12
                                                                     Cord push-button
                                                                     250 V with pull
P84034
P84267
                                                    Colour             2 modules
                                                      aluminium      MGU3.226.30
                                                      graphite       MGU3.226.12
          MGU3.226.30	MGU3.226.12                                    Cable length: 1 m
Inserts
                                           Colour            2 modules
                                             aluminium     MGU3.224.30
MGU3.224.30
                                           Colour            2 modules
                                             aluminium     MGU3.231.30
                                             graphite      MGU3.231.12
         MGU3.231.30
                                           		
                                            20 AX – 250 V high rating switch with amber indicator lamp
                                                           20 AX double pole one-way
P84033
                                           Colour            2 modules
                                               aluminium   MGU3.224.30S
                                                           Amber neon lamp, connected internally
         MGU3.224.30S
P84270
                                           Colour            2 modules
                                             aluminium     MGU3.232.30S
         MGU3.232.30S	MGU3.232.12S           graphite      MGU3.232.12S
                                                           Amber neon lamp, connected internally
Inserts
                            	Protection
                            	             Fuse holders
                                          10 A
P84115
                            Colour         1 module
                              aluminium   MGU3.630.30
                                          For cylindrical fuses up to 10 A with dimensions 6x32 mm
         MGU3.630.30
                                          16 A
P84117
                            Colour          2 modules
                              aluminium   MGU3.631.30
                              graphite    MGU 3.631.12
                                          For 00 type fuses
         MGU3.631.30
Inserts
                                                                  	             Comfort controls
                                                                  	             Rotary electronic dimmers switches
                                                                                40-400 W/VA one/two way switch                  60-400W/VA one way switch
P90600
P97788
P90597
                                                                  Colour          2 modules
                                                                    aluminium   MGU3.515.30
                                                                    graphite    MGU3.515.12
         MGU3.515.30                                                            Compliant with the interference suppression (EMC) standard EN 60669-2-1
         	
                                                                                                  Load table
                                                                                                Installation
                                                                                                Installed in place of a switch
                                                                                                May be controlled by push-buttons: up to 25 push-buttons in the surrounding
                                                                                                area
Inserts
P90607
         	
                                                             Load table
                               MGU3.524.XX MGU3.525.XX
                                                            Maximum loads
                               300 W          2300 W                                          230 V AC incandescent lamps
                                                            Installation
                                                            Parallel connection: max. 2 detectors for a load
                                                            Possibility of using up to 5 push-buttons in the surrounding area
Inserts
                                                     	Thermostats
P90596
                                  P84323
                                                                      8 A basic thermostat                          8 A resistive/5 A inductive weekly
                                                                                                                    programmable thermostat
                                                                      10 A floor thermostat
  P103850
                                                     Colour
                                                       aluminium      MGU3.503.30
                                                       graphite       MGU3.503.12
         MGU3.503.30                                                  Delivered with 4 m temperature sensor
                                                     Colour              2 modules
                                                       aluminium      MGU3.535.30
                                                       graphite       MGU3.535.12
         MGU3.535.30
                                                                      ● For all load types
                                                                      ● Adjustable disconnection time (2 s - 12 min.)
                                                                      ● Optional switching on using conventional push-button
                                                                      ● Included night blue locator lamp
                                                         Colour          2 modules
                                                          aluminium   MGU3.541.30
                                                          graphite    MGU3.541.12
         MGU3.541.30	
                                                                      ● 230 V 1200 W (incandescent and halogen)
                                                                      ● 1000 VA (halogen 12 V with electromagnetic transformer)
                                                                      ● 28 intervals
Inserts
                                                     	Weatherstation
                                                                   Weatherstation
     P84095
                                                     Colour           2 modules
                                                       aluminium   MGU3.546.30
                                                       graphite    MGU3.546.12
              MGU3.546.30	                                         ● Ambient temperature
                                                                   ● Atmospheric pressure
                                                                   ● Relative humidity
                                                     	             Wake up clock
                                                                   Wake up clock
     P84094
                                                     Colour           2 modules
                                                       aluminium   MGU3.545.30
                                                       graphite    MGU3.545.12
              MGU3.545.30	
                                                                   ● Double alarm
                                                                   ● “SNOOZE” function
                                                                   ● Indication of ambient temperature
P84281
for Unica Top for Unica Class for Unica Top for Unica Class
                                                                   MGU0.824
              MGU0.824
                                                     	             Technical alarms
                                                     	Detectors
    P101664
P101668
P101673
                                                     Colour         2 modules
                                                       aluminium   MGU3.713.30                              MGU3.712 (white)
              MGU3.713.30	             MGU3.712        graphite    MGU3.713.12
                                                     	             Power supplies
P101680
                                                     Colour         2 modules
                                                       aluminium   MGU3.716.30
              MGU3.716.12                              graphite    MGU3.716.12
Inserts
                                            	Socket-outlets
                                            	             German socket-outlets
P109652
P109661
                                            Colour          2 modules
                                              aluminium   MGU3.057.30SL
                                              graphite
                                              red         MGU3.057.03SL
          MGU3.057.30SL	
                                                          Side earth
                                                          16 A 2P + E, screw terminals
P83974
P84207
                                            Colour           2 modules
                                              aluminium   MGU3.036.30
                                              graphite    MGU3.036.12
          MGU3.036.30	MGU3.036.12                         Side earth
                                                          16 A 2P + E, shuttered,                       16 A 2P + E, shuttered,
                                                          screw terminals                               screw terminals, hinged flap
P83975
P84209
P109642
                                            Colour           2 modules
                                              aluminium   MGU3.037.30SL
                                              graphite    MGU3.037.12SL
          MGU3.040.30	MGU3.040.12             red         MGU3.037.03SL
                                                          Side earth
Inserts
                                                           French socket-outlets
     P109693
P109690
16 A 2P + E, shuttered, screwless
                                             Colour           2 modules
                                               aluminium   MGU3.059.30
                                               graphite    MGU3.059.12
               MGU3.059.30	MGU3.059.12
                                                           Pin earth
                                                           16 A 2P + E, shuttered, screwless with lamp
                                             Colour           2 modules
                                               red         MGU3.059.03SL
     P83977
P84210
                                                           Pin earth
                                                           16 A 2P + E, shuttered, screw terminals
                                             Colour           2 modules
               MGU3.039.30	MGU3.039.12
                                               aluminium   MGU3.039.30
                                               graphite    MGU3.039.12
     P109688
P109685
                                               red         MGU3.039.03
                                                           Pin earth
                                                           16 A 2P + E, shuttered, screw terminals with lamp
               MGU3.039.30SL	MGU3.039.12SL
                                             Colour           2 modules
                                               aluminium   MGU3.039.30SL
                                               graphite    MGU3.039.12SL
P140267
P140266
                                               red         MGU3.039.03SL
                                                           Pin earth
                                                           Italian socket-outlets
                                                           10 A 2P, Italian earth, shuttered, screw terminals
               MGU3.030.30	MGU3.030.12
P83971
P84204
                                             Colour         1 module
                                               aluminium   MGU3.030.30
                                               graphite    MGU3.030.12
MGU3.023.30 MGU3.023.12
                                             Colour         1 module
P83980
P93135
                                               aluminium   MGU3.023.30
                                               graphite    MGU3.023.12
                                                           British socket-outlets
                                                           13 A 2P + E, shuttered, screw terminals       15 A 2P + E, shuttered, screw terminals
               MGU3.045.30	MGU3.046.30
Inserts
                                                                       Special socket-outlet
         P124995
MGU3.077.30
                                                         	             European socket-outlets
                                                                       10 A 2P, shuttered, screw terminals              16 A 2P, shuttered, screw terminals
P83972
P84206
                                                         	             Euroamerican socket-outlets
                                                                       2P, shuttered, screw terminals
    P83969
                                                         Colour         1 module
                                                           aluminium   MGU3.021.30
                                                           graphite    MGU3.021.12
                   MGU3.021.30
                                                                       ●● 10 A - 250V AC for cylindrical pins
                                                                       ●● 15 A - 125V AC for flat pins
                                                         Colour            3 modules
                                                           aluminium   MGU3.068.30
                                                                       ●● 10 A - 250V AC for cylindrical pins
                                                                       ●● 15 A - 125V AC for flat pins
                   MGU3.068.30
                                                         Colour            3 modules
                                                           aluminium   MGU5.064.30
                                                                       Input: 240 V, output: 115/240 V, 50 or 60 Hz, for shaver only
MGU3.064.30
Inserts
                                               	             American socket-outlets
                                                             15 A 2P + E, screw terminals   15 A 2P + E, shuttered, screw terminals
                        P86091
P86071
MGU3.061.12
                                               Colour          2 modules
P109721
P109718
                                                 aluminium   MGU0.839.30
                                                 graphite    MGU0.839.12
          MGU0.839.30	MGU0.839.12
Inserts
                                             	                       Data sockets
                                             	                       RJ45 data sockets
                                                                     Category 5e, unshielded                                               Category 5e, shielded
  P84073
P84305
LexCom Infraplus
                                                                     Universal
                                  P84372
P84138
                                             	                       Actassi S-one RJ45 connectors reference numbers included into Unica data sockets:
                                                                     (1)
                                             	                         VDIB17725U, (2) VDIB17725B, (3) VDIB17726U, (4) VDIB17726B, (5) VDIB1772XU, 		
                                                                     (6)
                                             	                         VDIB1772XB.
                                                           P121211
P121214
P121212
P121215
P121213
P121216
Inserts
                                                      Common characteristics
                                                      ●● Ambient air temperature for operation: 5 to 35 °C
                                                      ●● Standard: IEC 60874
                                                      ●● Degree of protection: IP20/ IK04.
                             	
P132973
                             Colour
                               aluminium             MGU9.438.30
                                                     ●● Support to receive any SC simplex and duplex adapters
          MGU9.438.30                                ●● Support to receive Actassy optical fibre adapters:
                                                     ○ SC Duplex multi mode adapters: ref. n° VDIB6031001 and VDIB6031002
                                                     ○ SC Duplex single mode adapters: ref. n° VDIB6032001 and VDIB6032002
                                                     ○ SC APC Duplex single mode adapter: ref. n° VDIB6082001
                                                     ○ SC APC Simplex single mode adapter: ref. n° VDIB6072001.
                                           P133697
P133698
P133701
                                                                                                                                  P133695
                                                     VDIB6031001                     VDIB6032001              VDIB6082001                   VDIB6072001
                                                     VDIB6031002                     VDIB6032002
Inserts
                                            	             TV/FM/SAT sockets
                                            	             TV/FM sockets
                                                          TV/FM socket for parallel distribution systems
P84057
P84290
                                            	             R-TV/SAT sockets
                                                          R-TV/SAT socket for parallel distribution   R-TV/SAT socket for series distribution
P84060
P84293
systems systems
                                            Colour           2 modules
                                              aluminium   MGU3.456.30
                                              graphite    MGU3.456.12
                                                          ● 10-2400 MHz
                                                          ● Intermediate socket (passage)
                                            	             R/TV/SAT sockets
P140692
P140690
                                            Colour           2 modules
                                              aluminium   MGU3.450.30
                                              graphite    MGU3.450.12
          MGU3.450.30	MGU3.450.12                         ● R: 5-108 MHz / TV: 125-862 MHz / SAT: 950-2400 MHZ
                                                          ● Individual socket
                                            	             TV/SAT sockets
                                                          TV/SAT Female socket-F type
P84071
P84304
                                            Colour         1 module
                                              aluminium   MGU3.468.30
                                              graphite    MGU3.468.12
          MGU3.468.30	MGU3.468.12
Inserts
P84300
Male passage
                                   Colour              2 modules
                                     aluminium      MGU3.463.30
                                     graphite       MGU3.463.12
                                                    5-2150 MHz
P84303
Female passage
                                   Colour              2 modules
                                     aluminium      MGU3.466.30
                                     graphite       MGU3.466.12
                                                    5-862 MHz
P84370
Inserts
Telephone sockets
P84315
P84316
MGU3.497.30 MGU3.491.12
P107543
6 contacts screwless
                                                       Colour         1 module
            MGU3.499.30	MGU3.499.12                      aluminium   MGU3.499.30
                                                         graphite    MGU3.499.12
P124727
                                                       Colour          2 modules
                                                         aluminium   MGU3.498.30
                                                         graphite    MGU3.498.12
            MGU3.498.30	MGU3.498.12
                                                       	Indication
                                                       	             Indicator lamps
                                                                     Orange                                       Red
 P84122
P84123
Green Colourless
            MGU0.821
                                                                     MGU0.821
Inserts
Multimedia sockets
                                 HDMI sockets
                                 HDMI prewired socket
                   Colour         1 module
                     aluminium   MGU3.430.30
                     graphite    MGU3.430.12
                                 ●● Ambient air temperature for operation: - 5°C to + 40°C
                                 ●● Standards: EN 50157, EN 50049
                                 ●● Protection degrees: IP21/IK04
                                 RCA sockets
MGU3.430.30                      3 RCA female socket
                   Colour         1 module
                     aluminium   MGU3.431.30
                     graphite    MGU3.431.12
                                 ●● Connection: screw terminals
                                 ●● Clamping connection capacity: up to 1.5 mm2 rigid/stranded/flexible
                                 ●● Ambient air temperature for operation: - 5°C to + 40°C
                                 ●● Protection degrees: IP21/IK04
MGU3.431.30
                                 HD15 sockets
                                 HD15 female socket
                   Colour         1 module
                     aluminium   MGU3.432.30
                     graphite    MGU3.432.12
                                 ●● Ambient air temperature for operation: - 5°C to + 40°C
                                 ●● Protection degrees: IP21/IK04
MGU3.433.30
Inserts
MGU70.566.30
MGU70.598
                                                         Loudspeaker socket
P84080
P84314
                                           	             USB chargers
                                                         Single USB
                                           Colour         1 module
                                             aluminium   MGU3.428.30
                                             graphite    MGU3.428.12
                                                         ● Nominal input voltage: 100-240 V AC ±10 %
                                                         ● USB output voltage: 5 V DC ± 5 %
                                                         ● Nominal output current: 1 A
         MGU3.428.30                                     ● Power consumption: < 0.1 W (in stand-by)
                                                         ● Maximum output power: 7.5 W
                                                         ● Overvoltage category: OVC III
                                                         ● Isolation class: class II
Inserts
P84360
                                               	             Emergency light
                                                             Emergency light
P86079
                                                               2 modules
                                                             MGU3.776.T
          MGU3.776.T
                                               	Pilotlamp
                                                             Autonomous pilotlamp
 P86081
                                                               2 modules
                                                             MGU3.780.T
          MGU3.780.T
Inserts
                                            	             Complementary offers
                                            	             Cable outlet
                                                          16 A
P84129
P84361
P84373
                                            Colour         1 module
                                              aluminium   MGU9.868.30
                                            	Rockers
P140761
P140760
P140764
P140766
P140768
Wireless inserts
                                           	Emitters
                                           	               Battery powered push-button
                           P104955
                                                           For Unica Top cover frames                              For Unica Class cover frames
 P104564
+ + +
                                               Colour
                                                alu        MGU86.071.30                                      MGU88.071.30
                                                graphite   MGU86.071.12                                      MGU88.071.12
           MGU86.071.30
                                                           ●● Can control wireless receivers for light and/or roller blinds
                                                           ●● Supplied with a lithium battery, 1 large rocker, 2 narrow rockers and a set of symbols
                                                           ●● Flat fixing frame integrated to the product
Combined modules
                                                           With neutral
P104570
+ + +
                                               Colour
                                                alu        MGU3.572.30
           MGU3.572.30	                         graphite   MGU3.572.12
                                                           ●● Supplied with 1 large rocker and 2 narrow rockers
                                                           ●● Wireless receiver and emitter in one single product
                                           	               Combined dimmer
P104574
P104955
Without neutral
+ + +
                                               Colour
           MGU3.573.30                          alu        MGU3.573.30
                                                graphite   MGU3.573.12
                                                           ●● Supplied with 1 large rocker and 2 narrow rockers
                                                           ●● Wireless receiver and emitter in one single product
With neutral
+ + +
                                               Colour
                                                alu        MGU3.574.30
           MGU3.574.30                          graphite   MGU3.574.12
                                                           ●● Supplied with 1 large rocker and 2 narrow rockers
                                                           ●● Wireless receiver and emitter in one single product
Wireless inserts
                                                          	Receivers
                                                          	            Mobile socket-outlets relay (on/off)
P104580
P104582
                                                              Colour
                                                               white   CCT1A020                                       CCT1A022
          CCT1A020	CCT1A022                                            With one key for local control (switch)
P104583
                                                              Colour
                                                               white   CCT1A021                                       CCT1A023
          CCT1A021	CCT1A023                                            With one key for local control (dimmer)
           	
                                                                       Mobile socket-outlets load table
                                            CCT1A020      CCT1A021
                                            CCT1A022      CCT1A023
                                                                       Loads
                                            2300 W        250 W                                    230 V AC incandescent lamps and halogen lamps
Wireless inserts
Remote controls
8 keys to be customized
                                            Colour
                                             dark grey   CCT1A000
                                                         ●● Can control lights or/and roller blinds
                                                         ●● 8 keys to program in simple mode and scenario mode
                                                         ●● Supplied with 2 AAA batteries and 32 symbols
           CCT1A000
                                        	                Keyring remote control
                                                         4 keys
 P105422
                                            Colour
                                             dark grey   CCT1A010
                                                         ●● 4 keys to control lights and/or roller blinds
           CCT1A010                                      ●● Convenient design to be used as a keyring or to be placed in a pocket
                                                         ●● Supplied with Lithium CR2032 batteries
Complementary offer
                                   	                     Universal modules
                                                         Universal emitter
  P104585
                                            white        CCT1A030
           CCT1A030                                      ●● Converts mechanical push-button into a wireless emitter
                                                         ●● 4 RF channels
                                                         ●● Supplied with a lithium battery
                                                         ●● Never use switches, only push-buttons
                                                         Universal receiver relay
  P104586
                                            grey         CCT1A031
           CCT1A031                                      ●● Flush mounted or hidden in the ceiling
                                                         ●● Light: 10 A max.
                                                         ●● Engine: 3 A max.
                                   	                     Test kit
  P104584
P104584
RF signal tester
                                   	Accessories
 P104589
KNX inserts
                                                     	Introduction
          The following Unica control devices have to be            Loads
          connected to KNX bus line.
          The KNX bus line is laid in parallel to the 230 V
          power supply. 
                                                                    Actuators
                                                                                     Dimmer       Output        Shutter        Commissioning,
          When Unica sensor is activated (for example,              (command
                                                                                                  relay         control        visualisation of the installation ...
                                                                    receivers)
          a push-button), an actuator (e.g. the roller shutter
          control) will carry out all the switching commands
          required.
                                                                    Sensors
                                                                    (command
                                                                    givers)
                                                     	Controls
                                                     	Push-buttons
                                                                    2 buttons and 2 blue status LEDs,                     4 buttons and 4 blue status LEDs,
P117312
P117309
with screwless bus connecting terminals with screwless bus connecting terminals
P117313
                                                                    ●● With integrated bus coupler. The bus is    ●● With integrated bus coupler. The bus is
                                                                    connected using a bus connecting terminal. connected using a bus connecting terminal.
                                                                    Contents:                                     Contents:
                                                                    ●● With set of 10 symbols:                    ●● With set of 20 symbols:
                                                                    ○○ 2x symbol with light opening,              ○○ 4x symbol with light opening,
                                                                    ○○ 1x symbol “1”,                             ○○ 2x symbol “1”,
                                                                    ○○ 1x symbol “0”,                             ○○ 2x symbol “0”,
          MGU3.531.30	MGU3.531.12                                   ○○ 2x symbol for dimming,                     ○○ 4x symbol for dimming,
                                                                    ○○ 2x symbol for shutter,                     ○○ 4x symbol for shutter,
                                                                    ○○ 2x symbol (neutral).                       ○○ 4x symbol (neutral).
                                                                    ●● With bus connecting terminal.              ●● With bus connecting terminal.
                                                                    KNX software functions: Switching, toggling, dimming (single/dual-surface), blind (single/
                                                                    dual-surface), pulse edges trigger 1-, 2-, 4- or 8-bit telegrams (distinction between short
                                                                    and long operation), pulse edges with 2-byte telegrams (distinction between short and long
                                                                    operation), 8-bit linear regulator, scene retrieval, scene saving, disable functions.
P117317
                                                      Colour           2 modules
                                                        aluminium   MGU3.532.30
          MGU3.532.30	MGU3.532.12                       graphite    MGU3.532.12
                                                                    ●● The status LED is located under the symbol window which can be taken off.
                                                                    The functions of each of the button can be triggered using an IR remote control.
                                                                    The push-button is pre-programmed for operation with a Schneider-Electric IR remote control
                                                                    Distance. Many other IR remote controls (e.g. existing TV or CD player remote controls) can be
                                                                    taught into the push-buttons.
                                                                    ●● With integrated bus coupler. The bus is connected using a bus connecting terminal.
                                                                    ●● Transmitter: IR remote control Distance, ref. MTN570222.
                                                                    ●● Contents: With bus connecting terminal.
                                                                    KNX software functions: Switching, toggling, dimming (single/dual-surface), blind (single/
                                                                    dual-surface), pulse edges trigger 1-, 2-, 4- or 8-bit telegrams (distinction between short and
                                                                    long operation), pulse edges with 2-byte telegrams (distinction between short and long
                                                                    operation), 8-bit linear regulator, scene retrieval, scene saving, disable functions.
                                                                    Infra Red (IR) remote control for IR push-button receiver
P115471
                                                      Colour
                                                        black       MTN570222
                                                                    ●● 10-channel IR remote control
                                                                    ●● Battery: 2 microcells (IEC LR 03, AAA)
                                                                    ●● Range: up to 20 m
          MTN570222                                                 ●● Contents: without battery.
KNX inserts
                                    	             Comfort controls
P117324
P117321
                                    Colour           2 modules
                                      aluminium   MGU3.533.30
                                      graphite    MGU3.533.12
          MGU3.533.30	MGU3.533.12
                                                  When a movement is detected, a data telegram defined by the programming is transmitted.
                                                  ●● Two movement sensors: the sensitivity and range can be set separately for each sensor
                                                  ●● Detection angle: 180°
                                                  ●● Installation height : 1 m to 2.5 m
                                                  ●● Detection area at 2.15 m mounting height : Approx. 9 m on all sides, adjustable in 10 steps
                                                  (rotary switch or ETS)
                                                  ●● Detection brightness: Infinite setting from approx. 10 lux to approx.1000 lux (rotary switch)
                                                  or from 10 lux to 2000 lux (ETS)
                                                  ●● Overshoot time: Adjustable in 6 steps from approx. 1 s to approx. 8 min (rotary switch)
                                                  or adjustable from 1 s to 255 hours (ETS)
                                                  ●● EC guidelines: Low-voltage guideline 2006/95/EEC and EMC guideline 2004/108/EC
                                                  ●● With bus connecting terminal. The bus is connected using a bus connecting terminal.
                                                  KNX software functions: 5 movement blocks: up to 4 functions can be triggered per block.
                                                  Telegrams: 1 bit, 1 byte, 2 bytes.
P117328
P117325
                                    Colour           2 modules
                                      aluminium   MGU3.534.30
                                      graphite    MGU3.534.12
          MGU3.534.30	MGU3.534.12                 ●● With display and 4 buttons
                                                  ●● 2-step control, continuous PI controller, switching PI controller (PWM)
                                                  ●● Output: continuous in the range 0 to 100% or switching On/Off
                                                  ●● Controller mode:
                                                  ○○ Heating with one controller output
                                                  ○○ Cooling with one controller output
                                                  ○○ Heating and cooling with separate controller outputs
                                                  ○○ Heating and cooling with one controller output
                                                  ○○ 2-step heating with 2 control outputs
                                                  ○○ 2-step cooling with 2 control outputs
                                                  ○○ 2-step heating and cooling with 4 control outputs
                                                  ●● Operating modes: Comfort, comfort extension, standby, night reduction, frost/heat protection
                                                  Move all setpoints, save all setpoint temperatures and operating modes when reset, external
                                                  temperature monitoring, additional output of the control value as 1 byte value on the PWM.
                                                  With bus connecting terminal. The bus is connected using a bus connecting terminal.
                                            Type              1 gang
                                            zamak             MGU7.002
                                            plastic           MGU7.002.P
          MGU7.002                                            For attachable universal box
Fixing frame with short fixed claws Fixing frame with long fixed claws
                                            Type              2 gang
                                            plastic           MGU7.004.P                                    MGU7.892
                                                              For attachable universal box                  Set of 20 units
          MGU7.004.P
                                            	                Italian fixing frames
                                                              Italian fixing frames
P84442
P109738
                                                              Boxes
P84558
P86157
          MGU8.624	MGU8.603
                                                              2 x 4 modules           2 x 6 modules         3 modules                4 modules
                                                              MGU8.624                MGU8.626              MGU8.603                 MGU8.604
P85900
                                                              MGU8.601
          MGU8.601
          Version : 8.0 - 24 janvier 2017
          LSB03407EN
                                                                                                                                                          61
         www.schneider-electric.com
Unica Class
P113231
P113198
                                Natural Slate*
                                MGU68.002.7Z1
P113194
P113190
P113186
P113202
                                * Unica Class cover frames are made of true natural materials. For Slate, Oxide, and Leather
                                finishings, the typical natural aesthetic variations of each material have been respected.
                                They are present, making each cover frame unique and different from any other.
P1164 02
                                                          Slate
                                                           Minerals are timeless and eternal. Those qualities bring
                                                           a very special ambience into a room. Stone enhances
                                                           the simplicity in all strict and neat surroundings.
                                                           The individual patterns and shapes of minerals
P116402
          Now you can let this fine-grained and metamorphic rock adorn your
          home with its natural rough elegance and ancient beauty. The slate
          version of Unica Class deserves to be admired, but it handles actual
          touching as well, since it has been anti-fingerprint-treated.
                                                                                 P116737
                                                          Metal
                                                            It’s shining, it’s clean. The Unica Class steel and
                                                            aluminium covers have a solid elegance which enhances
                                                            spartan interior ideas.
P116412
P116604
                                                           Glass
                                                            Glass has been used in electric devices from electricity’s
                                                            earliest years. It was also the first modernist architects’
                                                            preferred material. And now the Unica Class cover frames
                                                            take the utilization and design of glass one step further.
P116397
P113239
                                                           Leather
                                                            No other material wears the years as well as leather.
                                                            It’s organic, which gives it a completely unique feeling and
                                                            fragrance. It also has an intriguing shine, which time will
                                                            increase. And the use of leather in cover frames is as
P116723
                                                            unusual as thrilling!
P116734
          The Unica Class frame covers are made of the best quality leather
          which heightens the level of sophistication in any distinguished setting.
          Choose between the vibrant chocolate colored Truffle and the creamy
          beige Sahara.
                                                                                      P116732
          Cover frames
P116439
1 gang
                          Colour
                           black mirror                 MGU68.002.7C1
          MGU68.002.7C2    white glass                  MGU68.002.7C2
                           grey glass                   MGU68.002.7C3
                           ice aluminium                MGU68.002.7A1
                           apple aluminium              MGU68.002.7A2
                           corten steel oxyde*          MGU68.002.7A3
                           slate*                       MGU68.002.7Z1
                           sahara leather*              MGU68.002.7P1
                           truffle leather*             MGU68.002.7P2
P116440
                          Colour
                           black mirror                 MGU68.004.7C1
          MGU68.004.7C2    white glass                  MGU68.004.7C2
                           grey glass                   MGU68.004.7C3
                           ice aluminium                MGU68.004.7A1
                           apple aluminium              MGU68.004.7A2
                           corten steel oxyde*          MGU68.004.7A3
                           slate*                       MGU68.004.7Z1
                           sahara leather*              MGU68.004.7P1
                           truffle leather*             MGU68.004.7P2
P116441
                          Colour
                           black mirror                 MGU68.006.7C1
          MGU68.006.7C2    white glass                  MGU68.006.7C2
                           grey glass                   MGU68.006.7C3
                           ice aluminium                MGU68.006.7A1
                           apple aluminium              MGU68.006.7A2
                           corten steel oxyde*          MGU68.006.7A3
                           slate*                       MGU68.006.7Z1
                           sahara leather*              MGU68.006.7P1
                           truffle leather*             MGU68.006.7P2
P116442
                          Colour
                           black mirror                 MGU68.008.7C1
          MGU68.008.7C2    white glass                  MGU68.008.7C2
                           grey glass                   MGU68.008.7C3
                           ice aluminium                MGU68.008.7A1
                           apple aluminium              MGU68.008.7A2
                           corten steel oxyde*          MGU68.008.7A3
                           slate*                       MGU68.008.7Z1
                           sahara leather*              MGU68.008.7P1
                           truffle leather*             MGU68.008.7P2
                          * Unica Class cover frames are made of true natural materials. For Slate, Oxide, and Leather
                          finishings, the typical natural aesthetic variations of each material have been respected. They
                          are present, making each cover frame unique and different from any other.
Unica Top
Wood
                        P86300
P86303
Metal
                          P86307
P86304
P86306
P86305
Bright chrome .010 Glossy chrome .038 Matt nickel .039 Metal grey .097
Colour
                    P86313
P86312
P86311
P86310
                                   Fluor green .094                Opal titanium .095            Onyx copper .096            Beryl blue .098
                        P86309
P86308
                                                                                                                                    8
                                                                                                                                 414
                                                                                                                              P10
Wood
                                   P86314
P86317
                                                                                                 P86315
                                             Cherry tree .2M2               Wengue .2M3                    Tobacco .2M4
Metal
                                  P86321
P86318
P86320
P86319
Bright chrome .210 Glossy chrome .238 Matt nickel .239 Metal grey .297
Colour
                                    P86327
P86326
P86325
P86324
                                             Fluor green .294               Opal titanium .295             Onyx copper .296                       Beryl blue .298
                                    P86323
P86322
Cover frames
                                                                       1 gang
P108325
P108379
Cover frames
P108411
MGU66.008.0M2
Cover frames
P109742
P109762
                                        cherry tree
                                        wengue
                                        tobacco
                                        bright chrome
                                        glossy chrome
                                        matt nickel
                                        top white
                                        onyx copper
                                        metal grey
                  aluminium
                  graphite
Cover frames
                                                             MGU66.103.039                   MGU66.103.239
                                             top white       MGU66.103.092                   MGU66.103.292
                                             rhodium black   MGU66.103.093                   MGU66.103.293
                                             fluor green     MGU66.103.094                   MGU66.103.294
                                             opal titanium   MGU66.103.095                   MGU66.103.295
                                             onyx copper     MGU66.103.096                   MGU66.103.296
          MGU66.103.OM4	                     metal grey      MGU66.103.097                   MGU66.103.297
                                             beryl blue      MGU66.103.098                   MGU66.103.298
                                             graphite                                        MGU6.103.12
                                             aluminium       MGU6.103.30
                                             gold                                            MGU66.103.204
Cover frames
                                              2 X 6 modules
P84574
Cover frames
Unica Plus
Unica Quadro
Unica Allegro
Unica Colors
Unica Basic
P90184
P86338
P86055
          design joy
                                                                                     thermostat
                                                                                     To have the home at the
                                                                                     right temperature every time
                                                                                     optimizing the energy.
                                                                         P105753
P105756
                                                                                        P105758
                                                                                                    with a movement detector.
                                                                                        P105759
                                                       buttons you are in charge from
                                             P105757
                                                       your sofa.
                                             P104878
                                                                                        P105760
                                                                                                    Technical alarms
                                                                                                    Protect your home against
                                                                                                    flooding and gas leaks.
                                                                                        P129485
                                                                     P90182
P90185
 P104129
Inserts
                                    	Controls
                                    	         10 AX – 250 V AC switches
                                              10 AX one-way screwless terminals          10 AX one-way screw terminals
P87310
P87282
                                    Colour      2 modules
                                      white   MGU3.211.18
          MGU3.211.18                 ivory   MGU3.211.25
                                              With internal power connection
P87329
                                    Colour      2 modules
          MGU3.213.18                 white   MGU3.213.18
                                      ivory   MGU3.213.25
                                              With external power connection
                                    	         16 AX – 250 V AC switches
                                              16 AX one-way screw terminals              16 AX double pole one-way
P138673
P138657
screw terminals
P138663
Inserts
P87283
P87288
P87303
P87304
                                                                                                 terminals
                                                                                 N
                                                                     1           L
Inserts
                                                               10 A – 250 V AC push-buttons
                                                               10 A screwless terminals                    10 A screw terminals
P87319
P87300
P87299
P104104
Inserts
                                                           	          10 A – 12 V AC push-buttons
P87321
P103831
                                                                      10 A screwless terminals with bell symbol      10 A screw terminals with illuminated label
                                                                                                                     holder
                                                           Colour       2 modules
                                                             white    MGU3.701.18
          MGU3.701.18                                        ivory    MGU3.701.25
                                                           Colour       2 modules
                                                             white    MGU3.579.18
          MGU3.579.18	                                       ivory    MGU3.579.25
                                                           	          Replacement lamps
                                                           	          LED for 250 V AC switches and push-buttons
                                                           	          with locator/indicator lamp
P127268
P127267
                                                           Colour
                                                             amber    MGU0.825.AL                                    MGU0.822.AL
          MGU0.825.AL                       MGU0.825.AZL     blue     MGU0.825.AZL                                   MGU0.822.AZL
                                                                      For switches and push-buttons with screwless   ●● Before November 2011, for all switches and
P86075
P86076
                                                           Colour
                                                             yellow   MGU0.823.AM
MGU0.823.AM
Inserts
                                                                	         Specialized controls
                                                                	         Mechanisms for roller blinds
                                                                          10 A switch screwless                           10 A push-button screwless
     P87327
P87326
P97785
P138654
                                                                Colour      1 module
               MGU3.109T.18                                       white   MGU3.109T.18
                                                                  ivory   MGU3.109T.25
                                                                          With mechanical and electrical safety latching to prevent simultaneous activation in both
                                                                          directions
                                                                	         Cord push-button
                                                                          250 V with pull
P87334
                                                                Colour      2 modules
                                                                  white   MGU3.226.18
               MGU3.226.18                                        ivory   MGU3.226.25
                                                                          Cable length : 1 m
P139119
Inserts
P87332
                                           Colour         2 modules
         MGU3.231.18                         white      MGU3.231.18
                                             ivory      MGU3.231.25
                                               Colour     2 modules
                                                white   MGU3.224.18S
         MGU3.224.18S                                   MGU3.224.25S
                                                ivory
                                                        Amber neon lamp, connected internally
                                           Colour         2 modules
                                             white      MGU3.232.18S
         MGU3.232.18S                        ivory      MGU3.232.25S
                                                        Amber neon lamp, connected internally
Inserts
                                   	Protection
                                   	         Miniature circuit breaker (MCB) switches
                                             6 A 1P                                        10 A 1P
P87411
P87412
                                             16 A 1P
P87413
                                   Colour     1 module
                                     white   MGU3.656.18
         MGU3.656.18                 ivory   MGU3.656.25
10 A 1P + N 16 A 1P + N
P87403
16 A (l∆n 10 mA)
                                   Colour      2 modules
                                     white   MGU3.612.18
                                     ivory   MGU3.612.25
                                   	         Fuse holders
                                             10 A
P87408
                                   Colour     1 module
                                     white   MGU3.630.18
         MGU3.630.18                 ivory   MGU3.630.25
                                             For cylindrical fuses up to 10 A with dimensions 6x32mm
                                             16 A
P87410
P87409
Inserts
                                                           	         Comfort controls
                                                           	         Rotary electronic dimmers switches
                                                                     40-400 W/VA one/two way switch                  60-400W/VA one way switch
P90555
P97787
                                                                                                                     40 - 1000 W/VA
                                  P90554
                                                           Colour      2 modules
         MGU3.515.18	                                        white   MGU3.515.18
                                                             ivory   MGU3.515.25
                                                                     Compliant with the interference suppression (EMC) standard EN 60669-2-1
         	
                                                                                      Load table
                                                                                     Installation
                                                                                     Installed in place of a switch
                                                                                     May be controlled by push-buttons: up to 25 push-buttons in the surrounding
                                                                                     area
Inserts
P90556
Load table
                               MGU3.524.XX MGU3.525.XX
                                                            Maximum loads
                               300 W          2300 W                                          230 V AC incandescent lamps
                                                            Installation
                                                            Parallel connection: max. 2 detectors for a load
                                                            Possibility of using up to 5 push-buttons in the surrounding area
Inserts
                                                    	Thermostats
P90551
                                 P87390
                                                                  8 A basic thermostat                          8 A resistive / 5 A inductive weekly
                                                                                                                programmable thermostat
                                                    Colour                                                           2 modules
         MGU3.501.18                  MGU3.505.18     white       MGU3.501.18                                     MGU3.505.18
                                                      ivory       MGU3.501.25                                     MGU3.505.25
                                                                  Used to control heating and air conditioning according to pre-programmed times
                                                                  and temperatures
                                                                  10 A floor thermostat
  P103847
                                                    Colour
                                                      aluminium   MGU3.503.18
         MGU3.503.18                                  graphite    MGU3.503.25
                                                                  Delivered with 4m temperature sensor
                                                    Colour           2 modules
                                                      white       MGU3.535.18
         MGU3.535.18                                  ivory       MGU3.535.25
                                                                  ● For all load types
                                                                  ● Adjustable disconnection time (2 s - 12 min.)
                                                                  ● Optional switching on using conventional push-button
                                                                  ● Included night blue locator lamp
                                                    Colour           2 modules
                                                      white       MGU3.541.18
         MGU3.541.18	                                 ivory       MGU3.541.25
                                                                  ● 230 V 1200 W (incandescent and halogen)
                                                                  ● 1000 VA (halogen 12 V with electromagnetic transformer)
                                                                  ● 28 intervals
Inserts
                                                   	Weatherstation
                                                                Weatherstation
P87395
                                                   Colour          2 modules
                                                     white      MGU3.546.18
          MGU3.546.18	                               ivory      MGU3.546.25
                                                                ● Ambient temperature
                                                                ● Atmospheric pressure
                                                                ● Relative humidity
                                                   	            Wake up clock
                                                                Wake up clock
P87394
                                                       Colour      2 modules
                                                        white   MGU3.545.18
                                                        ivory   MGU3.545.25
          MGU3.545.18	
                                                                ● Double alarm
                                                                ● “SNOOZE” function
                                                                ● Indication of ambient temperature
P87348
                                                                MGU0.824
          MGU0.824
                                                   	            Technical alarms
                                                   	Detectors
P101661
P101665
P101673
                                                   Colour        2 modules
                                                     white      MGU3.713.18                              MGU3.712 (white)
          MGU3.713.18	             MGU3.712          ivory      MGU3.713.25
                                                   	            Power supplies
P101678
                                                   Colour        2 modules
                                                     white      MGU3.716.18
          MGU3.716.18                                ivory      MGU3.716.25
Inserts
                                            	Socket-outlets
                                            	             German socket-outlets
P109650
P109663
P109658
                                            Colour           2 modules
                                              white       MGU3.057.18SL
          MGU3.057.18SL	MGU3.057.25SL
                                              red         MGU3.057.03SL
                                                          Side earth
P87274
P87277
screw terminals
P109644
                                            Colour           2 modules
          MGU3.037.18SL	MGU3.037.25SL         white       MGU3.037.18SL
                                              ivory       MGU3.037.25SL
                                              red         MGU3.037.03SL
                                                          Side earth
Unica Basic
                                            Colour
                                              white       MGU61.037.18
          MGU61.037.18                        ivory       MGU61.037.25
Inserts
                                           	         French socket-outlets
    P109691
P109692
16 A 2P + E, shuttered, screwless
                                           Colour      2 modules
                                             white   MGU3.059.18
              MGU3.059.18	MGU3.059.25
                                             ivory   MGU3.059.25
                                             red     MGU3.059.03
P87276
P107473
              MGU3.039.18	MGU3.039.25
                                           Colour      2 modules                                    2 modules
                                             white   MGU3.039.18                                  MGU3.039.18SL
    P109686
                                             ivory   MGU3.039.25
                                             red     MGU3.039.03                                  MGU3.039.03SL
              MGU3.039.18SL
  P140265
                                           	         Italian socket-outlets
                                                     10 A 2P + E, Italian earth, shuttered, screw terminals
                                           Colour     1 module
                                             white   MGU3.023.18
              MGU3.023.18                            MGU3.023.25
                                             ivory
                                           	         British socket-outlets
                                                     13 A 2P + E, shuttered, screw terminals     15 A 2P + E, shuttered, screw terminals
                              P93133
  P87279
Inserts
                                                	         Special socket-outlets
    P124993
                                                                   P93225
                                                Colour      2 modules                                       1 module
                                                  white   MGU3.047.18                                      MGU3.077.18
                                                  ivory   MGU3.047.25                                      MGU3.077.25
              MGU3.047.18	MGU3.077.18
                                                  red     MGU3.047.03
                                                	         European socket-outlets
                                                          10 A 2P, shuttered, screw terminals
    P87269
                                                Colour     1 module
                                                  white   MGU3.031.18
                                                  ivory   MGU3.031.25
              MGU3.031.18                                 Only for replacements in installations without
                                                          an earthing connection
                                                Colour      2 modules
                                                  white   MGU3.033.18
                                                  ivory   MGU3.033.25
              MGU3.033.18                                 Only for replacements
                                                	         Euroamerican socket-outlets
                                                          2P, screw terminals                              2P, shuttered, screw terminals
P87260
P87261
P101600
                                                Colour        3 modules
                                                  white   MGU3.068.18
                                                          ●● 10 A - 250V AC for cylindrical pins
                                                          ●● 15 A - 125V AC for flat pins
              MGU3.068.18
                                                          20 VA shaver socket, screw terminals
P104069
                                                Colour        3 modules
                                                  white   MGU5.064.18
                                                          Input: 240 V, output: 115/240 V, 50 or 60 Hz, for shaver only
MGU3.064.18
Inserts
                                       	         American socket-outlets
  P87267
P87268
terminals
                                       Colour      3 modules
                                         white   MGU3.061.18
           MGU3.061.18                   ivory   MGU3.061.25
                                       Colour      2 modules
                                         white   MGU0.839.18
             MGU0.839.18
Inserts
Unica Basic
                                                           Side earth, shuttered, screw terminals          Side earth, shuttered, screw terminals
                                           Only
         MGU23.065.18                      Unica Basic
P87434
                                           (1) ●●D: Individual packaging ; plastic bag and cardboard with eurohole
                                           (2) CZ/SK: Czech republic and Slovakia standard
                                           (3) PO/FR: Poland and France standard
MGU23.067.18
Inserts
                             Only
                             Unica Plus
                             Colour
                               white            MGU63.063.18
                               ivory            MGU63.063.25
                             Colour             white                   ivory
                               champagne        MGU63.063.824           MGU63.063.524
                               indigo blue      MGU63.063.842
         MGU63.063.18
                               terracota        MGU63.063.851
                               glacial blue     MGU63.063.854
                               apple green      MGU63.063.863           MGU63.063.563
                               mist grey        MGU63.063.865
                               pistachio        MGU63.063.866
                               sand             MGU63.063.867           MGU63.063.567
                               orange           MGU63.063.869
                               water green      MGU63.063.870
                               cacao            MGU63.063.871
                               garnet           MGU63.063.872
                               mink             MGU63.063.874
                               mauve            MGU63.063.876
                             Only
                             Unica Plus
                             Colour
                               white            MGU63.065.18                                    MGU63.065.18D     (1)
                               ivory            MGU63.065.25                                    MGU63.065.25D     (1)
                             Colour             white                   ivory                   white                   ivory
                               champagne        MGU63.065.824           MGU63.065.524           MGU63.065.824D    (1) MGU63.065.524D        (1)
         MGU63.065.18
                               indigo blue                                                      MGU63.065.842D    (1) MGU63.065.542D        (1)
                               terracota        MGU63.065.851           MGU63.065.551           MGU63.065.851D    (1) MGU63.065.551D        (1)
                               glacial blue     MGU63.065.854           MGU63.065.554           MGU63.065.854D    (1) MGU63.065.554D        (1)
                               apple green      MGU63.065.863                                   MGU63.065.863D    (1) MGU63.065.563D        (1)
                               mist grey        MGU63.065.865           MGU63.065.565           MGU63.065.865D    (1) MGU63.065.565D        (1)
                               pistachio        MGU63.065.866                                   MGU63.065.866D    (1) MGU63.065.566D        (1)
                               sand             MGU63.065.867           MGU63.065.567           MGU63.065.867D    (1) MGU63.065.567D        (1)
                               orange           MGU63.065.869           MGU63.065.569           MGU63.065.869D    (1) MGU63.065.569D        (1)
                               water green      MGU63.065.870                                   MGU63.065.870D    (1)
                               cacao            MGU63.065.871           MGU63.065.571           MGU63.065.871D    (1) MGU63.065.571D        (1)
                               garnet           MGU63.065.872           MGU63.065.572           MGU63.065.872D    (1) MGU63.065.572D        (1)
                               maganese blue                                                    MGU63.065.873D    (1)
                               mink             MGU63.065.874           MGU63.065.574           MGU63.065.874D    (1) MGU63.065.574D        (1)
                               mauve            MGU63.065.876                                   MGU63.065.876D    (1) MGU63.065.576D        (1)
                               slate grey       MGU63.065.877           MGU63.065.577           MGU63.065.877D    (1) MGU63.065.577D        (1)
                                                                                                DSO in pin pack
                             (1) ●●D: Individual packaging ; plastic bag and cardboard with eurohole
                             (2) CZ/SK: Czech republic and Slovakia standard
Inserts
                                           Only
                                           Unica Plus
                                           Colour
                                             white           MGU63.067.18                                   MGU63.067.18D     (1)
                                             ivory           MGU63.067.25                                   MGU63.067.25D     (1)
                                           Colour            white                  ivory                   white              ivory
                                             champagne       MGU63.067.824          MGU63.067.524           MGU63.067.824D (1) MGU63.067.524D (1)
                                             indigo blue     MGU63.067.842
         MGU63.067.18
                                             terracota       MGU63.067.851          MGU63.067.551
                                             glacial blue    MGU63.067.854          MGU63.067.554
                                             apple green     MGU63.067.863
                                             mist grey                                                      MGU63.067.865D
                                             pistachio       MGU63.067.866
                                             sand            MGU63.067.867          MGU63.067.567           MGU63.067.867D (1)
                                             orange          MGU63.067.869
                                             water green     MGU63.067.870                                  MGU63.067.870D (1)
                                             cacao           MGU63.067.871          MGU63.067.571
                                             garnet          MGU63.067.872          MGU63.067.572           MGU63.067.872D (1)
                                             mauve                                  MGU63.067.576
                                             slate grey      MGU63.067.877
                                                                                                            DSO in pin pack
                                           Only
                                           Unica Plus
                                           Colour
                                             white           MGU63.069.18
                                             ivory           MGU63.069.25
                                           Colour            white                  ivory
                                             champagne       MGU63.069.824          MGU63.069.524
         MGU63.069.18                        indigo blue     MGU63.069.842
                                             terracota       MGU63.069.851          MGU63.069.551
                                             glacial blue    MGU63.069.854
                                             apple green     MGU63.069.863
                                             mist grey       MGU63.069.865
                                             pistachio       MGU63.069.866
                                             sand            MGU63.069.867          MGU63.069.567
                                             orange          MGU63.069.869
                                             water green     MGU63.069.870
                                             cacao           MGU63.069.871
                                             garnet          MGU63.069.872
                                             maganese blue   MGU63.069.873
                                             mink            MGU63.069.874          MGU63.069.574
                                             mauve           MGU63.069.876
                                             slate grey      MGU63.069.877
                                           (1) ●●D: Individual packaging ; plastic bag and cardboard with eurohole
                                           (3) PO/FR: Poland and France standard
Inserts
                                       	                   Data sockets
                                       	                   RJ45 data sockets
                                                           Category 5e, unshielded                                               Category 5e, shielded
   P87373
P87372
P87423
LexCom Infraplus
P87428
Universal
                                       	                   Actassi S-one RJ45 connectors reference numbers included into Unica data sockets:
                                                           (1)
                                       	                     VDIB17725U, (2) VDIB17725B, (3) VDIB17726U, (4) VDIB17726B, (5) VDIB1772XU, 		
                                                           (6)
                                       	                     VDIB1772XB.
                                                 P121211
P121214
P121212
P121215
P121213
P121216
Inserts
                                                                             Common characteristics
                                                                             ●● Ambient air temperature for operation: 5 to 35 °C
                                                                             ●● Standard: IEC 60874
                                                                             ●● Degree of protection: IP20/ IK04.
                                                        	
P132975
P132971
                                                        Colour
                                                          white             MGU9.439.18                                     MGU9.438.18
                                                          ivory                                                             MGU9.438.25
          MGU9.439.18                     MGU9.438.18                       ●● Support to receive any SC simplex and duplex adapters
                                                                            ●● Support to receive Actassy optical fibre adapters:
                                                                            ○ SC Duplex multi mode adapters: ref. n° VDIB6031001 and VDIB6031002
                                                                            ○ SC Duplex single mode adapters: ref. n° VDIB6032001 and VDIB6032002
                                                                            ○ SC APC Duplex single mode adapter: ref. n° VDIB6082001
                                                                            ○ SC APC Simplex single mode adapter: ref. n° VDIB6072001.
                                                                  P133697
P133698
P133701
                                                                                                                                                        P133695
                                                                            VDIB6031001                     VDIB6032001              VDIB6082001                  VDIB6072001
                                                                            VDIB6031002                     VDIB6032002
Inserts
                                        	          TV/FM/SAT sockets
                                        	          TV/FM sockets
                                                   TV/FM socket for parallel distribution systems
P87357
                                        	          R-TV/SAT sockets
                                                   R-TV/SAT socket for parallel distribution   R-TV/SAT socket for series distribution
P87360
systems systems
                                         Colour       2 modules
                                           white   MGU3.456.18
                                           ivory   MGU3.456.25
                                                   ● 10-2400MHz
                                                   ● Intermediate socket (passage)
                                        	          R/TV/SAT socket
         P140691
                                         Colour       2 modules
                                           white   MGU3.450.18
                   MGU3.450.18                     ● R: 5-108 MHz / TV: 125-862 MHz / SAT: 950-2400 MHZ
                                                   ● Individual socket
                                        	          TV/SAT sockets
                                                   TV/SAT Female socket-F type
         P87371
                                         Colour     1 module
                                           white   MGU3.468.18
               MGU3.468.18                 ivory   MGU3.468.25
Inserts
P87367
Male passage
                                           Colour       2 modules
                                             white   MGU3.463.18
                                             ivory   MGU3.463.25
                                                     5-2150 MHz
P87370
Female passage
                                           Colour       2 modules
                                             white   MGU3.466.18
                                             ivory   MGU3.466.25
                                                     5-862 MHz
P87426
Inserts
Telephone sockets
P87382
P87383
                                                   Colour        1 module
                                                     white      MGU3.499.18
            MGU3.499.18	                             ivory      MGU3.499.25
                                                   Colour         2 modules
                                                     white      MGU3.498.18
                                                     ivory      MGU3.498.25
            MGU3.498.18
                                                   	Indication
                                                   	            Indicator lamps
                                                                Orange                                  Red
                           P87416
 P87415
                                                                Green                                   Colourless
 P87418
P87417
            MGU0.821
                                                                MGU0.821
            108                                                                                                        Version : 8.0 - 24 janvier 2017
                                                                                                                                       ISC01064EN
Unica Plus, Quadro, Allegro, Colors, Basic                                                                 www.schneider-electric.com
Inserts
Multimedia sockets
                                            HDMI sockets
                                            HDMI prewired socket
                                  Colour     1 module
                                    white   MGU3.430.18
                                    ivory   MGU3.430.25
                                            ●● Ambient air temperature for operation: - 5°C to + 40°C
                                            ●● Standards: EN 50157, EN 50049
                                            ●● Protection degrees: IP21/IK04
                                            RCA sockets
MGU3.430.18                                 3 RCA female socket
                                  Colour     1 module
                                    white   MGU3.431.18
                                    ivory   MGU3.431.25
                                            ●● Connection: screw terminals
                                            ●● Clamping connection capacity: up to 1.5 mm2 rigid/stranded/flexible
                                            ●● Ambient air temperature for operation: - 5°C to + 40°C
                                            ●● Protection degrees: IP21/IK04
MGU3.431.18
                                            HD15 sockets
                                            HD15 female socket
                                  Colour     1 module
                                    white   MGU3.432.18
                                    ivory   MGU3.432.25
                                            ●● Ambient air temperature for operation: - 5°C to + 40°C
                                            ●● Protection degrees: IP21/IK04
MGU3.433.18
Inserts
MGU70.566.18
MGU70.598
                                             Loudspeaker socket
P84080
P84314
                                   	         USB chargers
                                             Single USB
                                   Colour     1 module
                                     white   MGU3.428.18
                                     ivory   MGU3.428.25
                                             ● Nominal input voltage: 100-240 V AC ±10 %
                                             ● USB output voltage: 5 V DC ± 5 %
                                             ● Nominal output current: 1 A
         MGU3.428.18                         ● Power consumption: < 0.1 W (in stand-by)
                                             ● Maximum output power: 7.5 W
                                             ● Overvoltage category: OVC III
                                             ● Isolation class: class II
Inserts
P87420
                                           	         Emergency light
                                                     Emergency light
P86079
                                                       2 modules
                                                     MGU3.776.T
         MGU3.776.T
                                           	Pilotlamp
                                                     Autonomous pilotlamp
P86081
                                                       2 modules
                                                     MGU3.780.T
MGU3.780.T
Inserts
                                            	         Complementary offers
                                            	         Cable outlet
P87422
P87421
16 A
P87429
                                            Colour     1 module
                                              white   MGU9.868.18
                                              ivory   MGU9.868.25
                                            	Rockers
P140751
P140750
P140754
P140756
P140758
MGU9.200.18H MGU9.100.18H
Wireless inserts
                                                      	Emitters
                                                      	            Battery powered push-button
                                        P104957
 P104560
                                                                   For Unica Basic and Unica Colors                        For Unica Plus cover frames
                                                                   cover frames
+ + + + + +
                                                          Colour
                                                           white   MGU84.071.18                                       MGU86.071.18
            MGU84.071.18
                                                           ivory   MGU84.071.25                                       MGU86.071.25
                                                                   ●● Can control wireless receivers for light and/or roller blinds
                                                                   ●● Supplied with a lithium battery, 1 large cover (2 modules), 2 narrow covers (2 x 1 modules)
                                                                   and a set of symbols. Flat fixing frame integrated to the product
                                                      	            Combined modules
                                                      	            Combined relay (on/off)
  P104568
P104957
With neutral
+ + +
                                                          Colour
                                                           white   MGU3.572.18
            MGU3.572.18
                                                           ivory   MGU3.572.25
                                                                   ●● Supplied with 1 large cover (2 modules) and 2 narrow covers (2 x 1 modules)
                                                                   ●● Wireless receiver and emitter in one single product
                                                      	            Combined dimmer
P104572
                                                                   Without neutral
                                        P104957
+ + +
                                                          Colour
            MGU3.573.18                                    white   MGU3.573.18
                                                           ivory   MGU3.573.25
                                                                   ●● Supplied with 1 large cover (2 modules) and 2 narrow covers (2 x 1 module)
                                                                   ●● Wireless receiver and emitter in one single product
With neutral
+ + +
                                                          Colour
            MGU3.574.18                                    white   MGU3.574.18
                                                           ivory   MGU3.574.25
                                                                   ●● Supplied with 1 large cover (2 modules) and 2 narrow covers (2 x 1 module)
            	                                                      ●● Wireless receiver and emitter in one single product
Wireless inserts
                                              	Receivers
                                              	            Mobile socket-outlets relay (On/Off)
 P104580
P104582
                                                  Colour
           CCT1A020	CCT1A022                       white   CCT1A020                                         CCT1A022
                                                           With one key for local control (switch)
P104583
                                                  Colour
           CCT1A021	CCT1A023                       white   CCT1A021                                         CCT1A023
                                                           With one key for local control (dimmer)
           	
                                                           Mobile socket-outlets load table
                               CCT1A020      CCT1A021
                               CCT1A022      CCT1A023
                                                           Loads
                               2300 W        250 W                                              230 V AC incandescent lamps and halogen lamps
Wireless inserts
Remote controls
8 keys to be customized
                                                Colour
                                                 dark grey   CCT1A000
                                                             ●● Can control lights or/and roller blinds
                                                             ●● 8 keys to program in simple mode and scenario mode
                                                             ●● Supplied with 2 AAA batteries and 32 symbols
          CCT1A000
                                            	                Keyring remote control
                                                             4 keys
P105422
                                                Colour
                                                 dark grey   CCT1A010
                                                             ●● 4 keys to control lights and/or roller blinds
          CCT1A010                                           ●● Convenient design to be used as a keyring or to be placed in a pocket
                                                             ●● Supplied with Lithium CR2032 batteries
Complementary offer
                                            	                Universal modules
P104585
Universal emitter
                                                 white       CCT1A030
          CCT1A030                                           ●● Converts mechanical push-button into a wireless emitter
                                                             ●● 4 RF channels
                                                             ●● Supplied with a lithium battery
                                                             ●● Never use switches, only push-buttons
                                                             Universal receiver relay
P104586
                                                  grey       CCT1A031
          CCT1A031                                           ●● Flush mounted or hidden in the ceiling
                                                             ●● Light: 10 A max.
                                                             ●● Engine: 3 A max.
                                            	                Test kit
P104584
P104584
RF signal tester
                                            	Accessories
                                                             Set of scenario symbols
P104587
                                                Colour
                                                 white       MGU0.570.18
                                                 ivory       MGU0.570.25
                                                             Set content: 2x cooking, 2x diner, 2x little light, 2x much light, 2x at home, 2x leaving home,
                                                             2x TV, 2x empty.
          MGU0.570.18
KNX inserts
                                                     	Introduction
          The following Unica control devices have to be         Loads
          connected to KNX bus line.
          The KNX bus line is laid in parallel to the 230 V
          power supply. 
                                                                 Actuators
                                                                                 Dimmer       Output         Shutter     Commissioning,
          When Unica sensor is activated (for example,           (command
                                                                                              relay          control     visualisation of the installation ...
                                                                 receivers)
          a push-button), an actuator (e.g. the roller shutter
          control) will carry out all the switching commands
          required.
                                                                 Sensors
                                                                 (command
                                                                 givers)
                                                     	Controls
                                                     	Push-buttons
                              P117311
P117310
                                                                 2 buttons and 2 blue status LEDs,                 4 buttons and 4 blue status LEDs,
                                                                 with screwless bus connecting terminals           with screwless bus connecting terminals
P117315
                                                                 window which can be taken off.                    window which can be taken off.
                                                                 ●● With integrated bus coupler. The bus is        ●● With integrated bus coupler. The bus is
                                                                 connected using a bus connecting terminal.        connected using a bus connecting terminal.
                                                                 Contents:                                         Contents:
                                                                 ●● With set of 10 symbols:                        ●● With set of 20 symbols:
                                                                 ○○ 2x symbol with light opening,                  ○○ 4x symbol with light opening,
                                                                 ○○ 1x symbol “1”,                                 ○○ 2x symbol “1”,
                                                                 ○○ 1x symbol “0”,                                 ○○ 2x symbol “0”,
          MGU3.531.18	MGU3.531.25
                                                                 ○○ 2x symbol for dimming,                         ○○ 4x symbol for dimming,
                                                                 ○○ 2x symbol for shutter,                         ○○ 4x symbol for shutter,
                                                                 ○○ 2x symbol (neutral).                           ○○ 4x symbol (neutral).
                                                                 ●● With bus connecting terminal.                  ●● With bus connecting terminal.
                                                                 KNX software functions: Switching, toggling, dimming (single/dual-surface), blind (single/
                                                                 dual-surface), pulse edges trigger 1-, 2-, 4- or 8-bit telegrams (distinction between short
                                                                 and long operation), pulse edges with 2-byte telegrams (distinction between short and long
                                                                 operation), 8-bit linear regulator, scene retrieval, scene saving, disable functions.
P117318
P117319
                                                      Colour        2 modules
                                                        white    MGU3.532.18
          MGU3.532.18	MGU3.532.25                       ivory    MGU3.532.25
                                                                 ●● The status LED is located under the symbol window which can be taken off.
                                                                 The functions of each of the button can be triggered using an IR remote control.
                                                                 The push-button is pre-programmed for operation with a Schneider-Electric IR remote control
                                                                 Distance. Many other IR remote controls (e.g. existing TV or CD player remote controls) can be
                                                                 taught into the push-buttons.
                                                                 ●● With integrated bus coupler. The bus is connected using a bus connecting terminal.
                                                                 ●● Transmitter: IR remote control Distance, ref. MTN570222.
                                                                 ●● Contents: With bus connecting terminal.
                                                                 KNX software functions: Switching, toggling, dimming (single/dual-surface), blind (single/dual-
                                                                 surface), pulse edges trigger 1-, 2-, 4- or 8-bit telegrams (distinction between short and long
                                                                 operation), pulse edges with 2-byte telegrams (distinction between short and long operation), 8-
                                                                 bit linear regulator, scene retrieval, scene saving, disable functions.
P115471
                                                      Colour
                                                        black    MTN570222
                                                                 ●● 10-channel IR remote control
                                                                 ●● Battery: 2 microcells (IEC LR 03, AAA)
          MTN570222                                              ●● Range: up to 20 m
                                                                 ●● Contents: without battery.
KNX inserts
                                            	         Comfort controls
P117322
P117323
                                            Colour       2 modules
                                              white   MGU3.533.18
                                              ivory   MGU3.533.25
          MGU3.533.18	MGU3.533.25
                                                      When a movement is detected, a data telegram defined by the programming is transmitted.
                                                      ●● Two movement sensors: the sensitivity and range can be set separately for each sensor
                                                      ●● Detection angle: 180°
                                                      ●● Installation height : 1 m to 2.5 m
                                                      ●● Detection area at 2.15 m mounting height : Approx. 9 m on all sides, adjustable in 10 steps
                                                      (rotary switch or ETS)
                                                      ●● Detection brightness: Infinite setting from approx. 10 lux to approx.1000 lux (rotary switch) or
                                                      from
                                                      10 lux to 2000 lux (ETS)
                                                      ●● Overshoot time: Adjustable in 6 steps from approx. 1 s to approx. 8 min (rotary switch) or
                                                      adjustable from 1 s to 255 hours (ETS)
                                                      ●● EC guidelines: Low-voltage guideline 2006/95/EEC and EMC guideline 2004/108/EC
                                                      ●● With bus connecting terminal. The bus is connected using a bus connecting terminal.
                                                      KNX software functions: 5 movement blocks: up to 4 functions can be triggered per block.
                                                      Telegrams: 1 bit, 1 byte, 2 bytes.
P117326
P117327
                                            Colour       2 modules
                                              white   MGU3.534.18
                                              ivory   MGU3.534.25
          MGU3.534.18	MGU3.534.25
                                                      ●● With display and 4 buttons
                                                      ●● 2-step control, continuous PI controller, switching PI controller (PWM)
                                                      ●● Output: continuous in the range 0 to 100%
                                                      or switching ON/OFF
                                                      ●● Controller mode:
                                                      ○○ Heating with one controller output
                                                      ○○ Cooling with one controller output
                                                      ○○ Heating and cooling with separate controller outputs
                                                      ○○ Heating and cooling with one controller output
                                                      ○○ 2-step heating with 2 control outputs
                                                      ○○ 2-step cooling with 2 control outputs
                                                      ○○ 2-step heating and cooling with 4 control outputs
                                                      ●● Operating modes: Comfort, comfort extension, standby, night reduction, frost/heat protection
                                                      Move all setpoints, save all setpoint temperatures and operating modes when reset, external
                                                      temperature monitoring, additional output of the control value as 1 byte value on the PWM.
                                                      With bus connecting terminal. The bus is connected using a bus connecting terminal.
Fixing frames
                                 Type      1 gang
                                 zamak     MGU7.002
          MGU7.002               plastic   MGU7.002.P
                                           For attachable universal box
Fixing frame with short fixed claws Fixing frame with long fixed claws
                                 Type      2 gang
                                 plastic   MGU7.004.P                                   MGU7.892
          MGU7.004.P                       For attachable universal box                 Set of 20 units
P109738
Boxes
                                                               Boxes
                                               Unica Basic
                                               Unica Colors
                                               Only
                                               Unica Plus
                                                               Italian boxes
                                               Only
                                               Unica Allegro
P104741
             ENN35303	ENN37303
P87465
                                               Colour
                                                 white         MGU22.302.18                                   MGU22.304.18
P87466
MGU22.304.18
             MGU8.624
                                                               2 x 4 modules          2 x 6 modules           3 modules              4 modules
                                                               MGU8.624               MGU8.626                MGU8.603               MGU8.604
Unica Basic
MGU8.601
MGU8.601
Unica Plus
P90191
                                   P121411
       P84927
P84939
                                                                                                        P84928
                White .18                    Ivory .25                        Sand .x67                      Mist grey .x65
                                                                                                    P84940
      P84942
                                                                     P84945
                                   P84943
P84932
P84935
Water green .x70 Manganese blue .x73 Glacier blue .x54 Indigo blue .x42
                                                                                                      900
                                                                                                  P104
                                                                      P84941
                                           P84944
P84936
P84938
         Cover frames
P87459
1 gang
Cover frames
Cover frames
Cover frames
          Cover frames
P97396
Cover frames
                                                              2 x 6 modules
P87472
Cover frames
                                                 	                  Supplementary frames
                                                                      1 gang               2 gang
P87493
P87494
                                                 Colour
                                                   white              MGU6.502.18          MGU6.504.18
         MGU6.502.18               MGU6.504.18     ivory              MGU6.502.25
                                                                      3 gang
P87495
                                                 Colour
                                                   ivory              MGU6.506.25
MGU6.506.18
                                                 	
                                                                      Cover and fixing frame IP44
P87474
                                                 Colour
                                                   white              MGU61.002.18         MGU61.002.18G
         MGU61.002.18G	
                                                   ivory              MGU61.002.25         MGU61.002.25G
                                                   champagne          MGU61.002.824
                                                   indigo blue        MGU61.002.842
                                                   terracotta         MGU61.002.851
                                                   glacier blue       MGU61.002.854
                                                   apple green        MGU61.002.863
                                                   mist grey          MGU61.002.865
                                                   pistachio          MGU61.002.866
                                                   sand               MGU61.002.867
                                                   orange             MGU61.002.869
                                                   water green        MGU61.002.870
                                                   cacao              MGU61.002.871
                                                   garnet             MGU61.002.872
                                                   manganese blue     MGU61.002.873
                                                   mink               MGU61.002.874
                                                   mauve              MGU61.002.876
                                                   slate grey         MGU61.002.877
                                                   bright chrome      MGU61.002.810
                                                   gold               MGU61.002.804
          Unica Quadro
P104121
P105762
Metallized colours
P104530
                                                                     P104531
                     P104529
Natura colours
                                                                                                  P104525
                     P104522
P104523
P104524
                                                                                                       3
                                                                                                    490
                                                                                                 P10
Pearl colours
                             P104526
                                                                           P104528
                                                     P104527
Quadro colours
                                                       P104521
                              P104520
P104518
P104519
Cover frames
                                                 1 gang          2 gang
    P103781
                             Quadro
                              white              MGU2.702.18     MGU2.704.18
              MGU2.702.18     ivory              MGU2.702.25     MGU2.704.25
                              stone              MGU2.702.16     MGU2.704.16
                              Urban green        MGU2.702.17     MGU2.704.17
                             Quadro Natura
    P103785
                                                 3 gang          4 gang
P103789
                             Quadro
                              white              MGU2.706.18     MGU2.708.18
              MGU42.706.18     ivory             MGU2.706.25     MGU2.708.25
                              stone              MGU2.706.16     MGU2.708.16
                              Urban green        MGU2.706.17     MGU2.708.17
                             Quadro Natura
                              aqua               MGU4.706.26     MGU4.708.26
P103793
Cover frames
1 module 2 modules
                                        Quadro
                                         white              MGU2.801.18     MGU2.802.18
MGU2.801.18               MGU2.802.18    ivory              MGU2.801.25     MGU2.802.25
                                        Quadro Metallized
                                         silver             MGU2.801.55     MGU2.802.55
                                         titanium           MGU2.801.57     MGU2.802.57
3 modules
                                        Quadro
                                         white              MGU2.803.18     MGU2.804.18
MGU2.803.18               MGU2.804.18     ivory             MGU2.803.25     MGU2.804.25
                                        Quadro Metallized
                                         silver             MGU2.803.55     MGU2.804.55
                                         titanium           MGU2.803.57     MGU2.804.57
6 modules
                                        Quadro
                                         white              MGU2.806.18
                                          ivory             MGU2.806.25
MGU2.806.18                             Quadro Metallized
                                         silver             MGU2.806.55
                                         titanium           MGU2.806.57
Unica Allegro
P90177
P86331
P86343
P86341
Terracotta .51
P86340
                                                                                                           4
                                                                                                        490
                                                                                                     P10
          Champagne .24
                                                                       P86332
P86336
P86339
P86335
Cover frames
                                            1 module
P87455
                         Colour
                           white            MGU4.101.18
         MGU4.101.18       ivory            MGU4.101.25
                           bronze           MGU4.101.13
                           champagne        MGU4.101.24
                           aluminium        MGU4.101.30
                           indigo blue      MGU4.101.42
                           terracotta       MGU4.101.51
                           glacier blue     MGU4.101.54
                           technical grey   MGU4.101.58
                           cream            MGU4.101.59
                           dull silver      MGU4.101.60
                           graphite grey    MGU4.101.62
                           golden           MGU4.101.64
                           sand             MGU4.101.67
                                            2 modules
P87456
                         Colour
                           white            MGU4.102.18
         MGU4.102.18       ivory            MGU4.102.25
                           bronze           MGU4.102.13
                           champagne        MGU4.102.24
                           aluminium        MGU4.102.30
                           indigo blue      MGU4.102.42
                           terracotta       MGU4.102.51
                           glacier blue     MGU4.102.54
                           technical grey   MGU4.102.58
                           cream            MGU4.102.59
                           dull silver      MGU4.102.60
                           graphite grey    MGU4.102.62
                           golden           MGU4.102.64
                           sand             MGU4.102.67
                                            3 modules
P87457
                         Colour
                           white            MGU4.103.18
         MGU4.103.18       ivory            MGU4.103.25
                           bronze           MGU4.103.13
                           champagne        MGU4.103.24
                           aluminium        MGU4.103.30
                           indigo blue      MGU4.103.42
                           terracotta       MGU4.103.51
                           glacier blue     MGU4.103.54
                           technical grey   MGU4.103.58
                           cream            MGU4.103.59
                           dull silver      MGU4.103.60
                           graphite grey    MGU4.103.62
                           golden           MGU4.103.64
                           sand             MGU4.103.67
Cover frames
                                                              4 modules
P87458
                                           Colour
                                             white            MGU4.104.18
         MGU4.104.18                         ivory            MGU4.104.25
                                             bronze           MGU4.104.13
                                             champagne        MGU4.104.24
                                             aluminium        MGU4.104.30
                                             indigo blue      MGU4.104.42
                                             terracotta       MGU4.104.51
                                             glacier blue     MGU4.104.54
                                             technical grey   MGU4.104.58
                                             cream            MGU4.104.59
                                             dull silver      MGU4.104.60
                                             graphite grey    MGU4.104.62
                                             golden           MGU4.104.64
                                             sand             MGU4.104.67
                                                              6 modules
P93147
                                           Colour
                                             white            MGU4.106.18
         MGU4.106.18                         ivory            MGU4.106.25
                                             technical grey   MGU4.106.58
                                             aluminium        MGU4.106.30
                                             cream            MGU4.106.59
                                             graphite grey    MGU4.106.62
                                             indigo blue      MGU4.106.42
                                             glacier blue     MGU4.106.54
                                             terracotta       MGU4.106.51
                                             dull silver      MGU4.106.60
                                             champagne        MGU4.106.24
                                             bronze           MGU4.106.13
                                             golden           MGU4.106.64
                                             sand             MGU4.106.67
Unica Colors
P90200
                                                                     P84961
                                    P84960
                                                                                                     P84954
                 White .18                    Dull silver .60                 Champagne .24                    Technical grey .58
                                                                                                    P84967
                                                                 P84966
                                     P84955
        P84965
                                                                                                    P91464
                                   P84962
        P84963
                 Golden .64                   Bronze .13                      Moss green .06                   Pastry green .48
                                                                  P91463
      P91462
P84958
P84957
Pastel blue .34 Glacier blue .54 Lavender blue .05 Indigo blue .42
                                                                          02
                                                                     P1049
 P84956
P84959
Violet .31
           Cover frames
  P87451
1 gang
                          Colour
                            white   MGU4.002.18
           MGU4.002.18
                            ivory   MGU4.002.25
                                    2 gang
  P87452
                          Colour
                            white   MGU4.004.18
           MGU4.004.18
                            ivory   MGU4.004.25
                                    3 gang
  P87453
                          Colour
                            white   MGU4.006.18
           MGU4.006.18	     ivory   MGU4.006.25
                                    4 gang
  P87454
                          Colour
                            white   MGU4.008.18
           MGU4.008.18      ivory   MGU4.008.25
                                    5 gang
P104532
                          Colour
                            white   MGU4.010.18
           MGU4.010.18      ivory   MGU4.010.25
                          Colour
                            white   MGU22.302.18                     MGU22.304.18
           MGU22.302.18
                            ivory   MGU22.302.25                     MGU22.304.25
                                    Cover and fixing frame + box
P87450
         Cover frames
Decorative frames
                                                    Colour
                                                      white            MGU4.000.18
         MGU4.000.18	                                                  MGU4.000.25
                                                      ivory
                                                      royal yellow     MGU4.000.01
                                                      lavander blue    MGU4.000.05
                                                      moss green       MGU4.000.06
                                                      bronze           MGU4.000.13
                                                      champagne        MGU4.000.24
                                                      violet           MGU4.000.31
                                                      pastel blue      MGU4.000.34
                                                      indigo blue      MGU4.000.42
                                                      red              MGU4.000.43
                                                      beige            MGU4.000.44
                                                      pastry green     MGU4.000.48
                                                      terracotta       MGU4.000.51
                                                      glacier blue     MGU4.000.54
                                                      technical grey   MGU4.000.58
                                                      cream            MGU4.000.59
                                                      dull silver      MGU4.000.60
                                                      graphite grey    MGU4.000.62
                                                      golden           MGU4.000.64
                                                    	                  Supplementary frames
                                                                       1 gang
                                           P87491
P87490
                                                    Colour
                                                      white            MGU2.502.18
         MGU2.502.18	
P87492
Unica Basic
P105764
                                                                                      P86055
                                               P84953
P84951
P84952
          Cover frames
P87445
                                                     Colour
                                                       white                  MGU2.002.18                   MGU2.002.18M
          MGU2.002.18
                                                       ivory                  MGU2.002.25                   MGU2.002.25M
                                                       technical grey/white   MGU2.002.858
                                                       cream/ivory            MGU2.002.559
                                                       cream/white            MGU2.002.859
                                                                              2 gang
P87447
                                                     Colour
                                                       white                  MGU2.004.18
          MGU2.004.18	
                                                       ivory                  MGU2.004.25
                                                       technical grey/white   MGU2.004.858
                                                       cream/ivory            MGU2.004.559
                                                       cream/white            MGU2.004.859
                                                                              3 gang
P87448
                                                     Colour
                                                       white                  MGU2.006.18
          MGU2.006.18                                  ivory                  MGU2.006.25
                                                       technical grey/white   MGU2.006.858
                                                       cream/ivory            MGU2.006.559
                                                       cream/white            MGU2.006.859
                                                                              4 gang
P87449
                                                     Colour
                                                       white                  MGU2.008.18
          MGU2.008.18                                  ivory                  MGU2.008.25
                                                       technical grey/white   MGU2.008.858
                                                       cream/ivory            MGU2.008.559
                                                       cream/white            MGU2.008.859
                                                                              5 gang
P104534
                                                     Colour
                                                       white                  MGU2.010.18
                                                       ivory                  MGU2.010.25
          MGU2.010.18
MGU47.201.18P MGU47.202.18P
Cover frames
                                           Colour
                                             white   MGU22.302.18                     MGU22.304.18
         MGU22.302.18
                                             ivory   MGU22.302.25                     MGU22.304.25
                                                     Cover and fixing frame + box
Technical information
Contents
                                    page
Switches and push-buttons            156
MCB and RCD switches                 160
Fuse holders                         161
Rotary electronic dimmer switches    162
Push-button dimmer switches          166
Movement and presence detectors      167
Thermostats                          171
Weekly-programmable thermostats      173
Time-delay switches                  175
Weekly programmable timers           176
Weatherstations                      177
Wake up clocks                       178
Key card switches                    179
Technical alarms                     181
Socket-outlets                       182
RJ45 data sockets                    183
TV/FM/SAT sockets                    192
USB chargers                         194
In-wall bluetooth audio receivers    195
Telephone sockets                    197
Indicator lamps                      198
Buzzers                              199
Electronic bells                     200
Emergency lights                     201
Autonomous pilotlamps                202
Fixing frames                        203
Surface-mounted boxes                205
IP55 surface-mounted boxes           206
Flush mounting boxes                 207
Cover frames                         208
Technical information
Switches and push-buttons
Dimensions (mm)
Screwless terminals	              Screw terminals
control devices	                  control devices
(10 A devices)	                   (10 A and 16 A devices)
             22                                 21
        34                                 33
Technical information
Switches and push-buttons
              1           L                                                                            1       L
                                                                                                                                  4    3             1    L
                                        1       L                   1       L
2 2 2 2
2 1
L                                 L                                     L
N                                 N                                     N
          1           L       1                 1    2                            1     L                  1       L   1                   1   L
                                                L1   L2
2 2 L 2 2
Double one-way switch Double pole switch 2 two-way switches + 1 double two-way switch acting on two different loads
L                                 L
N                                 N
1 L
Technical information
Switches and push-buttons
L                               L                                        L                         L
N                               N                                        N                         N
           1           L                        1       L                         1   L                      1       L                    1       L
                                                                    or
                                                2                                 2                          2                            2
One-way switch                  Two-way switch (used as a one-way-switch) with locator lamp       2 two-way switches with locator lamps
with locator lamp
L                                                                                     L
N                                                                                     N
                                    4       3                                                                    4       3
       1           L                                        1   L                         1   L                                               1       L
                                                                             or
       2                                                    2                             2                                                   2
2 1 2 1
L                               L
N                               N
               4           3
                                        1           L
2 1
Technical information
Switches and push-buttons
L                                L                                        L
N                                N                                        N
           1       L                                 1   L
                                                                                      1     2
                                                                                     L1     L2
N 2 N
L                                                                     L
N                                                                     N
1 L 1 L 1 L 1 L
                                                                 or
               2       N                 2       N                              2     N                     2     N
L                                                                                           L
N                                                                                           N
                                     4       3
       1       L                                             1        L
                                                                                                  1     L
2 N 2 N
2 1
Technical information
Miniature circuit breaker switches
Residual current device switches
Area of application                                                 Technical data
● Miniature circuit breaker switches (MCB) and Residual cur-        ● Rated voltage: 230 V AC ± 10 %, 50 Hz.
rent device switches (RCD) are used in addition to the safety       ● MCB trip curve: the trip curve corresponds to the values specified in EN60898.
device installed at the incoming end of the system. They can                  t(s)
therefore significantly improve the protection of sensitive parts   10 000
of the system against overloads, short-circuits and bypass           5 000
faults.                                                              1h
                                                                     2 000
● Areas of domestic premises susceptible to humidity
                                                                     1 000
(bathroom, kitchen, laundry room, etc.) in accordance
                                                                      500
with IEC/UNE-EN Electrical Installations of Buildings
standards.                                                            200
● Power outlets for supplying electronic equipment                    100
(PCs and peripherals, typewriters, electronic scales, cash              50
registers, etc.).                                                       20
It is also possible to reduce and locate faulty areas                   10
and to increase the availability of the rest of the installation         5
upstream of this additional safety system.
                                                                         2
● Such items cannot be installed in MGU8.00X surface-
                                                                         1
mounted boxes, U10.002 and U11.002 IP55 surface-moun-
                                                                        .5
ted boxes and MGU61.002 IP44 cover and fixing frame
assemblies.                                                             .2
                                                                         .1
                                                                       .05
Standards                                                               .02
In accordance with EN 60898 and EN 61009-1:                             .01
● the electromagnetic part conforms to EN 60898                       .005
● the differential part conforms to EN 61009.
                                                                      .002
                                                                      .001
                                                                          .5 .7 1    2   3 4 5 7 10   20 30   50 70100   200300 I / In
Connections
MCB connection
                                                                    ● MCB rated currents (rating) and breaking capacities:
L
                                                                    Reference               Number of poles        Rating (A)            Breaking capacity (A)
N
                                                                    MGU3.654.XX             1                      6                     1500
                                                                    MGU3.655.XX             1                      10                    1500
                                                                    MGU3.656.XX             1                      16                    1500
                                                                    MGU3.614.XX             1+N                    10                    3000
                                                                    MGU3.615.XX             1+N                    16                    3000
              N
                                                                    ● RCD rated currents (rating) and breaking capacities:
                                Device                              Reference               Number of poles        Rating (A)            Breaking capacity (A)
                                to be protected
                                                                    MGU3.610.XX             1+N                    6                     1500
                                                                    MGU3.611.XX             1+N                    10                    3000
RCD connection                                                      MGU3.612.XX             1+N                    16                    3000
L                                                                   ● A circuit breaker installed on a vertical wall has a degree of protection to IP41.
N                                                                   ● The device must be used in a dry, dust-free area with an ambient temperature between
                                                                    -5°C and 40°C.
                                                                    ● The circuit can be closed manually by turning the circuit breaker handle in the direction
                                                                    of the «I» symbol.
                                                                    ● The circuit can be opened manually by turning the circuit breaker handle in the direction
                                                                    of the «O» symbol, or automatically by thermal or magnetic action.
                      N                                             ● With respect to the RCD, the circuit can also be opened by pressing the test button «T»
                                                                    and automatically by differential action.
                                                                    ● The test button «T» must be activated once a month.
                                      Device to be
                                                                    ● Fully protected rear screw terminals (IP2X) with toothed pressure plates and captive screws
                                      protected
                                                                    that can accept two 2.5 mm2 conductors.
        N                                                           ● The RCD sensitive to 10 mA can also operate in the presence of non-sinusoidal fault cur-
                                                                    rents (AC currents with superimposed unidirectional pulse currents). They can consequently be
                                                                    classified, according to the terms of EN 61009-1, as «type A differential circuit breakers» that
                                                                    can be identified by the appropriate symbol.
Dimensions (mm)
                    38
              54
Technical information
Fuse holders
Standards
● MGU3.630.XX: in accordance with EN 60127-6.
● MGU3.631.XX: in accordance with EN 60269.
                                                               MGU3.631.XX
                                                               Simply unscrew the fuse holder from the front face.
Dimensions (mm)
31
44
Technical information
Rotary electronic dimmer switches
MGU3.510.XX - 400 VA, 1-10 V
Area of application                                              Use
● Regulation of different loads (see load table) for homes
and buildings.                                                                                                                                          3
● Suitable for renovation as it allows replacement of a switch
or a selector switch by a regulator without having
 to change cables.                                                               min.
  ● As the regulator reduces the current supplying the load,
  it allows considerable energy savings.
 25 °C                                 1-10 V
 230 V
 50 Hz                                                                                                                1-10 V
Max.
VA       NO NO NO NO NO 400 NO NO NO                                                        L
1 - Incandescent lamps
2 - Halogen lamps
3 - Low voltage halogen lamps with ferromagnetic transformer
4 - Low voltage halogen lamps with electronic transformers
5 - Fluorescent lamps with conventional ballast
6 - Fluorescent lamps with dimmable electronic ballast (1- 10    L
V)                                                                                                                                                              N
7 - Compact fluorescent lamps
                                                                                                       > 400 VA
8 - LED lamps
9 - Motors (single phase)
Relay
Dimensions (mm)
                                                                                    34
                                                                             54
Technical information
Rotary electronic dimmer switches
MGU3.511.XX - 40-400 W/VA
Area of application                                              Use
● Regulation of different loads (see load table) for homes
and buildings.
● Suitable for renovation as it allows replacement of a switch
or a two-way switch by a regulator without having
to change cables.                                                                 min.
● As the regulator reduces the current supplying the load,
it allows considerable energy savings.
Technical data
● Rated voltage: 230 V AC ± 10 % 50 Hz.
● Possibility of connection with a two-way switch.
● Fuse: 4 Ah-230 V AC, 5 x 20 mm.
● Output power derating with 2 or 3 devices combining:
Configuration and number of combining devices
Load table
           1        2     3        4            5     6    7     Connections
 25 °C
                                                                 L                                                          N
 230 V                                                                              --.511.---
 50 Hz                                 1-10 V
                                                                 Substitution examples
                                                                 L                                 L
                                                                      One-way
                                                                      switch
N N
                                                                 L
                                                                      S1    S2                     L
                                                                      Two-way                           S1
                                                                      switch
                                                                                                                 Replace S2
                                                                 N                                 N
Dimensions (mm)
                                                                                   34
                                                                             54
Technical information
Rotary electronic dimmer switches
MGU5.512.XXZD - 40-1000 W/VA
Area of application                                              Use
● Regulation of different loads (see load table) for homes
and buildings.
● Suitable for renovation as it allows replacement of a switch
or a selector switch by a regulator without having to change
cables.
● As the regulator reduces the current supplying the load,
it allows considerable energy savings.
                                                                                                                                                4
                                                                             1
Technical data
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Output power derating with 2 or 3 devices combining:
Configuration and number of combining devices
                                                                                              min.
Output power derating
25 %         25 %               40 %             50 %
                                                                                                          2
Load table
           1         2      3      4         5    6      7
 25 °C
 230 V
 50 Hz                              1-10 V
MIN
L N
Dimensions (mm)
34
54
Technical information
Rotary electronic dimmer switches
MGU3.559.XX - 40-400 W - dual voltage
Area of application                                              Use
● Regulation of different loads (see load table) for homes
and buildings
● Suitable for renovation as it allows replacement of a switch
by a regulator without having to change cables.
● As the regulator reduces the current supplying the load,
it allows considerable energy savings.
Technical data
● Rated voltage: 127/ 230 V AC, 50/60 Hz.
● Connectable as switch.
● Fuse: 4 Ah- 230 V AC, 5 x 20 mm.
2 devices in the same housing is not allowed                                                           OK
Load table
                1           2         3            4   5    6
                                                                 Connections
    25 °C
    50/60 Hz
                                          1-10 V
                                                                 L                                                          N
127 V AC
Max.           250
Min.           40         NO         NO            NO NO NO
W/VA
230 V AC
Max.           400
Min.           60         NO         NO            NO NO NO
W/VA
                                                                                               F4AH
                                                                                   34
                                                                              50
Technical information
Push-button dimmer switches
MGU3.515.XX - 20-350 W/VA
Area of application                                              Use
● Regulation of different loads (see load table) for homes
and buildings.
● Suitable for renovation as it allows replacement of a switch                                                                             min.
or a selector switch by a regulator without having
to change cables.
● As the regulator reduces the current supplying the load,
it allows considerable energy savings.
Technical data
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Conventional push-buttons with or without indicator lamp
can be used for on/off control and regulation of the load:
○ maximum number of push-buttons without indicator lamp:
25
○ maximum number of push-buttons with indicator lamp:
5 (1.5 A).
● Output power derating with 2 or 3 devices combining:
Configuration and number of combining devices
Load table
         1    2      3      4      5         6   7      8   9                                                                                min.
 25 °C
 230 V                                                                  Long press                                                            Off
 50 Hz                              1-10 V
Max.     250 350   350     300                       200 350                          “Long “Long            “Long “Short “Short
Min.     20 20     20      20     NO NO NO 20            20                           press” press”          press” press” press”
W/VA                                                                                  Off    On              Off    Off    On
1 - Incandescent lamps
2 - Halogen lamps
3 - Low voltage halogen lamps with ferromagnetic transformer     Connections
or electronic transformer
4 - Low voltage halogen lamps with toroïdal transformers
5 - Fluorescent lamps with conventional ballast or dimmable      L                                                              N
electronic ballast (1- 10 V)
6 - Compact fluorescent lamps
7 - LED lamps
8 - Ventilators
9 - Heaters
Standards
In accordance with EN 60669-2-1.
Dimensions (mm)
                                                                                 34
                                                                           47
Technical information
Movement and presence detectors
MGU3.524.XX- 300 W
Area of application                                            Use
● The movement detection control switch switches on
the loads, it controls when someone passes through the area             max.
                                                                                                   OK !
of action of the sensor.                                                2.15 m
● It is suitable for different loads (see load table).
● It can be installed indoors in flush-mounted installations        min.
and in surface-mounted boxes.                                       1.2 m
● The control switch allows considerable energy savings
since the load is supplied only when people are present.
Technical data
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Movement detection area:
○ 10 x 20 m (PIR mouting height: 2.15 m)
○ 9 x 18 m (PIR mouting height: 1.2 m).
● Presence detection area:
○ 6 x 12 m (PIR mouting height: 2.15 m).
○ 5 x 10 m (PIR mouting height: 1.2 m).
● Detection angle: full 180°, partial 90° left or right.
● Selection modes:                                                                                                      2s             20
                                                                   M         A           5 lux         1000 lux
○ Manual; the load is controlled by a push-button,                                                                                     min.
○ Automatic; the load is controlled by the detection
of movement and a pre-defined luminosity threshold.                M: manual: the load is controlled by a push-button
● Two detectors can be used in parallel, allowing a larger         A: automatic: the load is controlled by the detection of movement
detection area coverage.                                           and a pre-defined luminosity threshold.
● Time delay: ajustable 2 s to 20 min.
● Luminosity threshold: ajustable 5 to 1000 lux.
                                                                                               180°
Load table
            1          2       3         4   5   6    7
                                                                                                 90°
 25 °C
 230 V
 50 Hz                          1-10 V
Max.      300
Min.      40          NO      NO NO NO NO NO                                                     90°
W/VA
1 - Incandescent lamps, halogen lamps or heaters (Pf > 0.9)
2 - Low voltage halogen lamps with ferromagnetic or toroïdal
transformer or with electronic transformer                     Connections
3 - Fluorescent lamps with conventional ballast or dimmable
electronic ballast (1- 10 V)                                   L                                                              N
4 - Compact fluorescent lamps
5 - LED lamps
6 - Ventilators
7 - Contactors
Standards
In accordance with EN 60669-2-1.
                                                               Substitution examples
                                                               L                                  L
                                                                    One-way
                                                                    switch
N N
                                                               L                                  L
                                                                   S1       S2                         Replace
                                                                    Two-way                            S1
                                                                    switch
                                                                                                                 Replace S2
                                                               N                                  N
Technical information
Movement and presence detectors
MGU3.524.XX - 300 W (cont’d)
                        Detection areas
                                                         6m                       10 m    5m
                                              12 m
                        10 m                                    9m
                                                                                  18 m
                                              20 m
                                                               18 m
                        20 m
                                                                                  18 m
                                               20 m
Dimensions (mm)
                                             34
                                      58
Technical information
Movement and presence detectors
MGU3.525.XX- 2300 W
Area of application                                             Use
● The movement detection control switches on
the loads, it controls when someone passes through the area                   max.
of action of the sensor.                                                      2.15 m
● It is suitable for different loads (see load table).
● It can be installed indoors in flush-mounted installations             min.
and in surface-mounted boxes.                                            1.2 m
● The control switch allows considerable energy savings
since the load is supplied only when people are present.
Technical data
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Movement detection area:
○ 10 x 20 m (PIR mouting height: 2.15 m)
○ 9 x 18 m (PIR mouting height: 1.2 m).
● Presence detection area:                                                S                    S                          S
○ 6 x 12 m (PIR mouting height: 2.15 m).
○ 5 x 10 m (PIR mouting height: 1.2 m).
● Detection angle: full 180°, partial 90° left or right.                       A
● Selection modes:                                                                                                            2s         20
                                                                                          5 lux         1000 lux
○ Manual; the load is controlled by a push-button,                       M          S                                                    min.
○ Automatic; the load is controlled by the detection
of movement and a pre-defined luminosity threshold.             M: manual; the load is controlled by a push-button
○ Slave; slaves detectors are used in conjonction               A: automatic; the load is controlled by the detection of movement and a pre-defined
with a master detector, allowing a larger detection area        luminosity threshold.
coverage.                                                       S: slave; slaves detectors are used in conjonction with a master detector,
● Time delay: ajustable 2 s to 20 min.                          allowing a larger detection area coverage.
● Luminosity threshold: ajustable 5 to 1000 lux.
                                                                                            180°
Load table
         1   2    3     4     5     6     7    8     9     10
                                                                                             90°
25 °C                                                                S
230 V
50 Hz
Max.
W/VA    2300 2000 1050 1150 2000 500 500 200 2300 200
1 - Incandescent lamps                                                                        90°
2 - Halogen lamps
3 - Low voltage halogen lamps with ferromagnetic transformer
4 - Fluorescent lamps with conventional ballast, Pf > 0.9
5 - Low voltage halogen lamps with electronic transformers      Connections
6 - Compact fluorescent lamps
7 - LED lamps                                                    L                                                                  N
8 - Ventilators
9 - Heaters
10 - Contactors
Standards
In accordance with EN 60669-2-1.
                                                                Substitution examples
                                                                L                             L            L                       Compulsory
                                                                     One-way                                                       neutral
                                                                     switch
                                                                                                            N
                                                                N                             N
                                                                                              This wiring diagram works
                                                                                              only if the neutral is distributed
                                                                L                                                 L
                                                                                              L
                                                                     S1        S2
                                                                     Two-way                                       N
                                                                     switch                         Replace
                                                                                                    S1           Replace S2
                                                                N                             N
Version : 8.0 - 13 décembre 2016
ISC01064EN
                                                                                                                                                       169
Unica                                                                                www.schneider-electric.com
Technical information
Movement and presence detectors
MGU3.525.XX - 2300 W (cont’d)
                        Detection areas
                                                         6m                                      10 m   5m
                                             12 m
                        10 m                                             9m
                                                                                                 18 m
                                              20 m
Master Master
30 m 27 m
                                                                                 Slave 2                  Slave 1
                                  Slave 2                Slave 1
                                                                                                 18 m
                                              20 m
                                                                                           ...
                        ● Max 5 slaves to 1 master
                        ● Max 5 push-buttons to 1 slave
                        ● Use normally open push-button
                        ● Push-buttons are optional with master PIR in automatic mode
                        ● Slave PIR time delay should be less tan Master PIR time delay
Dimensions (mm)
                                             34
                                      58
Technical information
Thermostats
MGU3.501.XX- 8 A basic thermostat
Area of application                                               Use
● Residential sector:
○ homes with local heating
○ homes with central heating
○ homes with local air-conditioning.
● Tertiary sector:
○ environments with fan air-conditioning
○ environments with central heating and zone valves.
● Can be used on a boiler or circulating pump circuit (heating)        1.5 m
or on the air-conditioning power circuit. .
Technical data
                                                                                                                   Air conditioning
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Settings range: + 5 °C to + 30 °C.
● Accuracy: 0.5°C.                                                Supply voltage
● The comfort temperature is set via a graduated dial on
                                                                                                                   Heating
the front panel.
● Load types:
○ 8 A (resistive)
○ 2 A, Pf (cosφ) = 0.6 (inductive).
● Free potential relay contact.
● Protection against thermal overloads: the mechanism
is protected against a connected load that is greater than
the permissible load.                                             Connections
● A green LED indicates that a voltage is present.                Heating
● Red/blue dual-coloured LED: heating or cooling indication
○ red indicates that the relay is enabled and that the comfort    L                                                              N
temperature is higher than the ambient room temperature
(heating application)
○ blue indicates that the relay is not enabled and that                              .501.
the comfort temperature is lower than the ambient room
temperature (air-conditioning application).
Standards
In accordance with:
● EN 607320-2-9.
● LV and EMC directives.
                                                                  Air-conditioning
                                                                   L                                                         N
.501.
Dimensions (mm)
                                                                                    33
                                                                               45
Technical information
Thermostats
MGU3.503.XX - MGU5.503.XX ZD - 10 A floor thermostat
Area of application                                         Use
Floor heating for homes.
Technical data
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Settings range: + 5 °C to + 45 °C.
● Accuracy: 0.5 °C.                                             1.3 m
● The comfort temperature is set via a graduated dial on
the front panel.
● Load types: 10 A, resistive load, cosφ = 1 (2300W).
● Indication:
○ green LED indicates that a voltage is present.            Supply voltage                                     Heating
○ red LED indicates that the relay is enabled and that
the comfort temperature is higher than the ambient room
temperature.
● A floor temperature sensor is delivered with each floor
thermostat:
○ impedance: 10 kW at 25°C, NTC sensor
○ lenght: 4 m.
Standards
In accordance with:
                                                            Connections
● EN 607320-2-9.
● LV and EMC directives.                                    L                                                            N
Sensor
                                                            Connection terminals:
                                                            ●	 L and N: screw connection for cables up to 2 x 2.5 mm2
                                                            ●	 sensor: screw connection for cables up to 2 x 1.5 mm2.
Dimensions (mm)
                                                                             33
                                                                        45
Technical information
Weekly-programmable thermostats
MGU3.505.XX - 8 A resistive/5 A inductive
Area of application                                               Use
● Residential sector:                                             User data
○ homes with local heating                                        ● AUTO: The automatic thermostat function switches the heating or air-conditioning on
○ homes with central heating                                      or off according to pre-programmed times and temperatures.
○ homes with local air-conditioning.                              ● MAN: The manual thermostat function allows you to select the required temperature
● Tertiary sector:                                                at any given time. It cancels the automatic function.
○ environments with fan air-conditioning                          ● Tmin: Tmin is the so-called economy temperature, namely the temperature at which
○ environments with central heating and zone valves.              the environment is maintained during the user’s absence or for the purposes of minimum
● Can be used on a boiler or circulating pump circuit (heating)   comfort. In theory, it is used during the day or at night-time.
or on the air-conditioning power circuit.                         The values for this temperature category are normally between 18 °C and 20 °C.
                                                                  ● Tmax: Tmax is the so-called comfort temperature.
                                                                  It is the temperature chosen to give a sensation of maximum comfort. The comfort temperature
Technical data                                                    values are normally between 21 °C and 22 °C.
● Rated voltage: 230 V AC ± 10 %, 50 Hz.                          ● SUITCASE: The thermostat shutdown function is used for holiday periods or periods
● Application 1: the heating is connected via terminals           of absence during which only the frost-protection function is enabled. The day this function
C (common) and NO (normally open).                                is to come into effect can be set in AUTO mode.
● Application 2: the air-conditioning is connected via            ● CAL: Temperature sensor calibration : the temperature measured by the thermostat
terminals C (common) and NC (normally closed).                    is adjusted to match the actual temperature in the event of the equipment being affected
● Standard programming (user-modifiable).                         by nearby heat sources or draughts. The temperature can be increased or lowered perma-
● Maximum number of weekly program settings: 1.                   nently by up to 5 °C.
● Maximum number of programmable changes: no limit.               ● DIF: Differential : the differential is the variation in temperature required to switch
● Heating (Heat) or air-conditioning (Cool) can be                the thermostat on or off. The values for this parameter are normally 0.3 °C. In other words,
programmed in INSTALLER PARAMETERS.                               if a differential of 0.5 °C is programmed and the comfort temperature is 22 °C, the thermostat
● Memory with no 230 V AC power supply: 7 days.                   switches on at 21.5 °C and off at 22 °C.
● Relative operating humidity: 20 to 85%.                         ● Frost-protection: This is the frost-protection temperature, namely the temperature at which
● Programmable temperatures: Tmax, Tmin, frost protection         the heating switches on, even if the thermostat is switched off or in SUITCASE mode.
and differential.                                                 This temperature is usually 6 °C. Thus, when the thermostat measures a temperature of 6 °C,
● Ambient room temperature display: 0 to 45°C (tenths).           it switches on the heating to prevent the pipes or other units in the house from freezing.
● Selectable temperature set point: increments of 0.5°C.
● Operating temperature: 0 to 50°C.                               Keys
● Settings range: 5 to 35°C.                                                    Menu/ On -Off
● Storage temperature: -5 to 55°C.                                              This key is used to select the various programming states in turn. Press OK
● Relay contact interrupting capacity: 8 A resistive,                           to access the various states. Press this key for five seconds
5 A inductive.                                                                  (only from AUTO or MANUAL mode) to switch off the weekly thermostat.
● Type of contact: free potential.                                              Press again to restart the thermostat.
● Type of device to EN60730: type 1B.                                           Increase values/ SELECT
● Software class: A.                                                            The programming (PRG) mode is used to select Tmax,
● Device class: II.                                                             Tmin and frost-protection ( ) in turn.
                                                                                Decrease values/ COPY
Standards                                                                       The programming mode (PRG) is used to copy the current day’s schedule
In accordance with EN 60730-2-9.                                                to the following day.
                                                                                When COPY flashes, press OK to confirm.
                                                                                Confirm values and actions/ Holiday mode
                                                                                Press this key for five seconds (only from AUTO or MANUAL mode) to switch
                                                                                to SUITCASE mode          (time-delayed disconnect for holiday purposes).
                                                                                Simultaneously press the MENU and OK keys for 10 s (only from AUTO mode)
                                                                                to restore the original parameters. Press the « » and « » keys for 5 s
                                                                                (only from AUTO mode) to access INSTALLER PARAMETERS.
                                                                                Press the « » and « » keys for 5 s (only from AUTO mode) to access INSTALLER
                                                                                PARAMETERS.
4 4
5 6
                                                                  6
                                                                                                                     5
                                                                  7                                                  7
                                                                  8                                                  8
Technical information
Weekly-programmable thermostats
MGU3.505.XX- 8 A resistive/ 5 A inductive (cont’d)
                         Installation
                                                       NO      NO                               NO
> 1.5 m
                         Connections
                         Heating                                         Air-conditioning
C C
                                505                                              505
                             230 V ~ 50 Hz                                    230 V ~ 50 Hz
                         L                                                L
                         N                                                N
                         ● Terminal identification : L (phase), N (neutral), C (common), NO (normally open)
                         and NC (normally closed).
                         ● The heating is connected via terminals C and NO.
                         The air-conditioning is connected via terminals C and NC.
                         ● Connection terminals: screw connection for cables up to 2 x 1.5 mm2.
Dimensions
                                                  33
                                             45
Technical information
Time delay switches
MGU3.535.XX
Area of application                                            Use
● Installation in toilets, corridors, staircases, etc.
● Pulse-type switch on of the load and automatic
disconnection when the programmed time limit has expired.
● Incorporated blue locator lamp.
Technical data
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Technology: relay.
● Maximum load: 8 A.
● Connection time setting by potentiometer.
● Setting time: from 2 s to 12 min.
● Conventional push-buttons with or without indicator lamp
can be used for on/off control of the load:
○ maximum number of push-buttons without indicator lamp:
25,
○ maximum number of push-buttons with indicator lamp: 5.
● Output power derating with 2 or 3 devices combining:
Configuration and number of combining devices
                                                                                                             t = t1 + t2
Output power derating                                                                       t2              t1             t2
25 %         25 %               40 %          50 %
Load table                                                         On
         1    2      3      4      5     6      7      8
                                                                                On               On              On
25 °C
                                                                   Off
230 V
50 Hz
Standards                                                                               L
In accordance with EN 60669-2-1.
Dimensions
                                                                               34
                                                                          47
Technical information
Time delay switches
MGU3.535.XX
Area of application                                            Use
The programmable time switch is used to control the loads      User data
according to a set schedule. It is programmed in intervals.    ● AUTO: The automatic programmable time switch function connects or disconnects the load
An interval can represent switching on or off, depending       according to the programmed interval times.
on the time and day programmed. The intervals are displayed    ● MAN: The manual programmable time switch function allows you to connect the load
on the screen.                                                 at a time that is not programmed.
                                                               ● INTERVAL: Period of time between connection and disconnection, depending on the time
                                                               and day programmed.
Technical data                                                 ● SUITCASE: This function prevents the time switch from being set during holiday periods
● Rated voltage: 230 V AC ± 10 %, 50 Hz.                       or periods of absence. The day this function is to come into effect can be set in AUTO mode.
● Maximum number of intervals: 28 (56 On/Off actions).         Keys
● Memory with no 230 V AC power supply: 7 days.                          Menu/ On-Off
● Relative operating humidity displayed: 20 % to 85 %.                   This key is used to select the different programming states in turn. Press OK
● Ambient room temperature display: 0 to 50 °C (tenths).                 to access the various states.
● Minimum interval duration: 1 min.                                      Press this key for 5 s in AUTO mode to switch to MANUAL mode. The MANUAL mode
● Operating temperature: 0 to 50 °C.                                     is used to connect or disconnect the load.
● Storage temperature: -5 to 55°C.
● Type of contact: free potential.                                       Increase values/ SELECT
● Type of device to EN60669-2-1: 1B.                                     During programming, this function is used to choose sequentially between On and
● Software class: A.                                                     Off. When MEM (memory) is displayed, it is possible to choose between Mod
● Device class: II.                                                      (modify memory) and Del (partial programming deletion).
Load table                                                               Decrease values/ COPY
         1       2     3     4     5    6    7     8       9
                                                                         During programming, this button allows copying the program of the current day to the
                                                                         next day. It allows selecting between the MEM and COPY menus.
                                                               Installation
                                                                                       NO           NO                         NO
> 1.5 m
                                                                                541
                                                                               230 V ~ 50 Hz
                                                                                                                                             33
                                                               L                                                                        45
                                                               N
                                                               Connection terminals: screw connection for cables up to 2 x 1.5 mm2.
Technical information
Time delay switches
MGU3.535.XX
Area of application                                              Use
● The weather station screen displays the time,                  Keys
temperature, humidity, atmospheric pressure, moon phase                     Weather station menu/ On-Off
and the minimum and maximum temperatures for the last                       This menu is used to select the screen display mode which may be sequential
two weeks. It also has a function that forecasts the weather                or fixed. Press this button for more than 15 s to shut down the weather workstation.
according to changes in atmospheric pressure. The weather
forecasting function is 75 % reliable.
                                                                            Increase values/ SELECT
● The user can set the following parameters: either
                                                                            This option is used to increase the displayed value during programming.
the screen changes sequentially every 15 s, or it remains
                                                                            Press the button for more than 5 s to open the Installer parameters menu.
unchanged.
● The user can switch off the weather station during a holiday
                                                                            Decrease values
period or period of absence.
7 8 9 10 11
                                                                 Installation
                                                                                       NO                        NO                    NO
> 1.5 m
Connections
                                                                                          546
                                                                                       230 V ~
                                                                                       50/60Hz
                                                                 L
                                                                 N
                                                                 Connection terminals: screw connection for cables up to 2 x 1.5 mm2.
Dimensions (mm)
                                                                                  33
                                                                             45
Technical information
Wake up clocks
MGU3.545.XX
Area of application                                              Use
● The alarm clock screen displays the time, temperature          Keys
and the alarms programmed during the day. The user can                      Alarm clock menu / On-Off
set 9 alarms for different times and different days.                        This button is used to select the various possible states in turn. Press OK to access
● It is also possible to set the “Snooze” and alarm repeat                  the various states. Press this button for more than 15 s to switch the alarm clock off.
functions for a specific number of minutes. The bell displayed
on the screen ( ) indicates that at least one alarm was set
during the week.                                                            Increase values / SELECT
● The “Date-Year” function is incorporated in the alarm clock.              This option is used to choose sequentially between switching the alarm on and off
It allows the winter/summer changeover time to be set                       during programming.
automatically.
● When the alarm is triggered, it can be stopped by pressing                Decrease values
any key. If the “Snooze” function is set, the OK key stops
the alarm permanently. Press one of the other buttons
(“Menu”, “ ” and “ ”) to activate the alarm repeat function,
which starts after the number of minutes set with the “Snooze”              Confirm values and actions
function have expired.
Standards
In accordance with EN 60669-2-1.
                                                                 Installation
                                                                                       NO                NO                       NO
> 1.5 m
Connections
                                                                                          545
                                                                                       230 V ~
                                                                                       50/60Hz
                                                                  L
                                                                  N
                                                                 Connection terminals: screw connection for cables up to 2 x 1.5 mm2.
Dimensions (mm)
                                                                                  33
                                                                             45
Technical information
Key card switches
MGU3.540.XX (8 A timed) - MGU3.283.XX (10 A)
Area of application                                                    Installation (MGU3.540.XX)
● Particularly recommended for hotel rooms.
● Controls lighting circuits, electrical appliances, electronic
equipment, etc.
Technical data
MGU3.540.XX (8 A timed)
● Power supply: 230 V AC ± 10 %, 50 Hz.
● Rated current: 8 A.
                                                                                                                                         NO
● A flashing LED indicates that the time-delay is off.
● The disconnect time can be any time between                          Unica Basic and Unica Colors	               Unica Class, Unica Top and Unica Plus
10 s and 3 min.
● Type of card: 54 x 86 x 0.85 mm (max.), vertical insertion.
● With an amber night-time indicator lamp.                                                   NO
● Fuse: electronic.
● Protection: against overvoltages and thermal protection.
● Relay contact: free potential.
                                                                       Unica Top, Unica Plus and Unica Allegro (Italian cover frames)
25 °C
                                    1-10 V
230 V
50 Hz
Max.
                                                                       Use (MGU3.540.XX)
W/VA    1470   1000 1470 1470 NO 1470 1470 1470 1470 xx
MGU3.283.XX (10 A)
● Power supply: 230 V AC ± 10 % 50 Hz.
● Rated current: 10 A.
● Type of card: 54 x 86 x 0.85 mm (max.), vertical insertion.
● With an amber night-time indicator lamp (ref. MGU.824).
● The supply is interrupted when the card is removed
(45 to 54 mm wide).
● For fluorescent loads with a corrected power factor, the load
should be controlled through an appropriate relay.
                                                                       Installation (MGU3.283.XX)
Standards
● MGU3.540.XX: in accordance with EN 60669-2-1.
● MGU3.283.XX: in accordance with EN 61058-1.
                                                                                                                                              NO
Unica Quadro, Unica Colors and Unica Basic Unica Top, Unica Plus and Unica Allegro
Use (MGU3.283.XX)
Technical information
Key card switches
MGU3.540.XX (8 A timed) - MGU3.283.XX (10 A) (cont’d)
                        Connections (MGU3.540.XX)
                        < 8 A	                                           >8A
                        L                                        N       L                                      N
                        Connections (MGU3.283.XX)
                        6 A max. (Faston)	                               10 A ( soldering)
                        Dimensions (mm)
                        Unica Class, Unica Top, Unica Plus	                  Unica Basic, Unica Colors
                        and Unica Allegro	                                   and Unica Quadro
                                  14                                                 14
                             35                                                 36
Technical information
Technical alarms
MGU3.710.xx - MGU3.711.xx - MGU3.713.xx - MGU3.712
Area of application                                               Use
Two kinds of technical alarms are available to guard against      ●● When the detectors are activated, an alarm is triggered, a red LED flashes and a powerful
potential danger for homes and building:                          audible signal is given.
●● Gas detectors: they are used to sound an alarm as soon as      ●● The detectors have potential free switch over contact, one NO and one NC to connect directly
light gasses (natural gas, city gas, methane ...) or heavy        to a solenoid valve or siren.
gasses (butane, propane...) start to dissipate into the ambiant   ●● The detectors are equiped with a test button on front face; they must be tested at regular
air. Gas detectors are designed to be installed in boiler rooms   intervals to ensure that they are operating correctly.
and kitchen or other places where there is a risk of gas          ●● The gas detectors have a limited life time cycle of 5 years after the 1st installation.
escapes.                                                          On the front cover a label has to be inserted to indicate the expire date of the gas detector.
●● Flood detector: it is designed to detect a water leakage in
order to prevent water damage. It is connected to SE3.712
sensor, located just a few centimeters off the floor.             Connections
Technical data                                                    Gas detectors connection
●● Gas detectors                                                  127 or 230 V AC /12 V AC                                                           Solenoid valve
                                                                  power supply
●● Power supply: 12 V AC/DC.                                                                                                    L              N     on NC (normally
                                                                                                                                                     closed) contact
●● Signalling:
○○ alarm indication: red LED,
○○ power indication: green LED,
○○ stabilization indication during switch on
and malfunction indication: amber LED,
○○ life time indication: label on front face.
●● Test button on front face for simulation.
●● Operating temperature: 5 to 40 °C.
●● Operating consumption: 130 mA.
●● Alarm level: 85 bB -1 m.
●● Output contacts: potential free switch over contacts (NO,
NC) for connecting solenoid valve on available voltage (12 V,
24 V or 127 V AC or 230 V AC).
●● Installing recommendations:                                        N
○○ 50 cm from the ceiling for methane gas detectors,
○○ 50 cm from the floor for LPG gas detectors.                        L
                                                                  Connection terminals: screw connection for cables up to 2 x AWG16 (2 x 1.5 mm2).
Flood detectors
●● Power supply: 12 V AC/DC.
●● Signalling:
○○ alarm indication: red LED,                                     Flood detector connection
○○ power indication: green LED,
●● Test button on front face for simulation.
●● Operating temperature: 5 to 40 °C.                                                                                       L              N
●● Operating consumption: 63 mA.
●● Alarm level: 85 bB -1 m.
●● Output contacts: potential free switch over contacts (NO,
NC) for connecting solenoid valve on available voltage (12 V,
24 V or 127 V AC or 230 V AC).
○○ A flood sensor ( SEU.712) is delivered with each flood
detector.
Standards
●● Quality marks: CE
●● Standard: EN 50194.
                                                                  N
                                                                  L
                                                                  Connection terminals: screw connection for cables up to 2 x AWG16 (2 x 1.5 mm2).
                                                                  *Use of a maximum of 3 sensors in parallel.
                                                                  Dimensions (mm)
                                                                             50
                                                                                   33
Technical information
Socket-outlets
                                                                        1                          2                                 3
Technical data
● Insulation resistance: > 5 MΩ/ 500 V.
● Dielectric strength: > 2000 V.
● Minimum breaking capacity: 100 operations at 1.25 x In
and 1.1 x In, where Pf (Cos φ) = 0.6.
● Enveloping and elastic cells.
● For operations, the earthing contact is made first
and broken last.
● Minimum useful life: 10,000 position changes at In and Vn,
where Pf (Cos φ) = 0.8.
● Materials: self-extinguishing technopolymer with excellent                                                                     3
impact strength. The front parts are resistant to cleaning                                                    2                  4
products and to UV radiation. They are halogen-free.
● The main sockets are also available in red to distinguish                                                   1
the circuits: identification of circuits supplied by uninterruptible
power supply (UPS), AC networks or stabilised networks.
Connections
● Screws or screwless connection:
○ screw connection by mixed head screw,                                Dimensions (mm)
○ screwless connection without tool.
● Terminals accessible on a side part of the socket facilitating       10/16 A- 2P, German type	       10/16 A- 2P, European type          10 A- 2P, European type
connection of terminals and insertion of the device in the box                                         10/16 A- 2P + E, French type	
as the rear part remains free of cables.
● Terminals for cables up to 4 mm2, rigid or flexible.
● Screw connection by mixed head screw supplied loosened.
Standards
In accordance with IEC 60884-1 and the following national
standards depending on the country use: VDE 0620-1,
UNE 20315-1-2, NFC 61-314, NOM-003-SCFI-2000,
SI 32, BS 1363-1 and BS 546:1950.
                                                                                   30                              27                                   27
                                                                                                               37                                  37
                                                                               40
                                                                                   24                              30
                                                                              33                              33
                                                                                   24                                    40
                                                                            33.5                                    52
Technical information
RJ45 data sockets
                                                                                   L2 L1
                                                                              TX           TS                   PAR3
                                                                          2                     T
                                                                      B                             A    PAR2    PAR1     PAR4
                                                                     1 2 3 4 5 6 7 8                     1 2 3 4 5 6 7 8
                                                                                                                RJ45
                                                                     Dimensions (mm)
                                                                     RJ45 cover	                         RJ45 socket
                                                                               10                                    25
                                                                          21                                    36
Technical information
RJ45 data sockets (cont’d)
                        SYSTIMAX ®
                        Connector ref.   Type               Compatibility           Compatibility
                                                            with MGU9.460.XX        with MGU9.461.XX
                                                            universal cover         universal cover
MPS100E-xxx Cat. 5 ●● ●●
                        BRAND REX ®
                        Connector ref.     Type              Compatibility          Compatibility
                                                             with MGU9.460.XX       with MGU9.461.XX
                                                             universal cover        universal cover
                        C6C-JAK-U-01-2     UTP     Cat. 6    ●●                     ●●
                        C6C-JAK-U-01-3                       ●●                     ●●
                        C6C-JAK-F-OK-2     FTP               ●●                     ●●
                        C6C-JAK-F-AK-2                       ●●
                        C6C-JAK-F-BK-2                       ●●
                        GPC-JAK-U-A1-3                       ●●                     ●●
                        GPC-JAK-U-BK-3                       ●●                     ●●
                        GPC-JAK-U-AK-3                       ●●                     ●●
                        GPC-JAK-U-01-                        ●●                     ●●
                        3LF
                        GPC-JAK-F-01-      FTP               ●●                     ●●
                        2LF
                        GPC-JAK-F-B1-2                       ●●
                        GPC-JAK-F-A1-3                       ●●
                        GPC-JAK-F-BK-2                       ●●
                        GPC-JAK-F-AK3                        ●●
Technical information
RJ45 data sockets (cont’d)
                                                  ®
                                   KRONE
                                    Connector ref.      Type                     Compatibility             Compatibility
                                                                                 with MGU9.460.XX          with MGU9.461.XX
                                                                                 universal cover           universal cover
                                    6380 1 800-04       UTP     Cat. 6           ●●                        ●●
                                    6380 1 810-04       STP                      ●●
                                    6830 1 305-01       UTP                      ●●                        ●●
                                    6830 1 312-xx       STP                      ●●
                                    6540 1 100-07       UTP     Cat. 5           ●●                        ●●
                                    6540 2 161-60       STP                      ●●
                                    6540 1 130-xx       UTP                      ●●                        ●●
                                    6540 1 154-02       STP                      ●●
                                    6467 1 081-xx       UTP                      ●●                        ●●
                                   NEXANS ®
                                    Connector ref.    Type                 Compatibility                    Compatibility
                                                                           with MGU9.460.XX                 with MGU9.461.XX
                                                                           universal cover                  universal cover
                                    N420.610          UTP      Cat. 6      ●●                               ●●
                                    N420.620          FTP                  ●●                               ●●
                                    N420.630          STP                  ●●                               ●●
                                    N420.510          UTP      Cat. 5      ●●                               ●●
                                    N420.520          FTP                  ●●                               ●●
                                    N420.530          STP                  ●●                               ●●
                                    N420.416          UTP                  ●●                               ●●
                                    N420.426          FTP                  ●●                               ●●
                                   NORDX/CDT ®
                                    Connector ref.             Type                   Compatibility         Compatibility
                                                                                      with MGU9.460.XX      with MGU9.461.XX
                                                                                      universal cover       universal cover
                                    AX101318 to 101328         UTP      Cat. 6        ●●                    ●●
                                    AX101307 to 101317                  Cat. 5        ●●                    ●●
AX100577 to 100587 ●● ●●
                                   SUPERIOR ®
                                    Connector ref.      Type                      Compatibility
                                                                                  with MGU9.460.XX
                                                                                  universal cover
                                    KMJSIXB02           UTP       Cat. 6          ●●
                                    KMJVL8A/B02S        FTP                       ●●
                                    KMJVL8A/B02                   Cat. 5          ●●
                                                        UTP
                                    KMJEFS8B02                                    ●●
Version : 8.0 - 13 décembre 2016
ISC01064EN
                                                                                                                               185
Unica                                                                                        www.schneider-electric.com
Technical information
RJ45 data sockets (cont’d)
Installation
Example of unshielded data socket installation (cat 6A, 5, 5e)
A U/UTP 1 2 3
                                                                                 2 mm maxi
                             60 mm
B 1 2
3 4
Technical information
RJ45 data sockets (cont’d)
 5                                     6             7
           12345678
                            5
  6
                            4
  3
                            8
  2
                            7
  1
                            5
 6
                            4
 3
                            8
 2
                            7
 1                                               m
                                           0,5 m i
      EIA-TIA 568A (100Ω)
                                             max
C 1
                    41 mm
                     mini
2 3
Technical information
RJ45 data sockets (cont’d)
Installation
Example of shielded data socket installation (cat 6A, 5, 5e)
 A       F/UTP                1                                2
                              100 mm
x1
3 4 5 6
                                                                       2 mm maxi
20 mm
Technical information
RJ45 data sockets (cont’d)
A 1 2
S/FTP
                                               x1
                                                                     F/FTP
 3                             4                       5                                      6
     P
                                                                                                  P
   FT
FT
FT
                                                                                                FT
 S/
S/
S/
                                                                                              S/
                                                                                                             10 %
                              20 mm
 3                                            4                                 5
     TP
TP
                                                                                     TP
    F
                                                                                    F
 F/
F/
                                                                                 F/
                                               20 mm
Technical information
RJ45 data sockets (cont’d)
Installation
Example of shielded data socket installation (cat 6A, 5, 5e) (Cont’d)
                                                                              41 mm
                                                                               mini
C 1 2
RJ11 RJ 45
Technical information
RJ45 data sockets (cont’d)
                                         41 mm
                                          mini
C 1 2
RJ11 RJ 45
Technical information
TV/FM/SAT sockets
Technical information
TV/FM/SAT sockets
TV/FM/SAT sockets
                                                                                       MGU3.459.XX                          MGU3.458.XX
                                                                                       intermediate series                  end-of-line
                                                                                       (passage) max 4 units                series
                                                                                                                            (terminal)
                                                                           Tap-off units
TV socket Cover
Dimensions (mm)
          18
      28                           9
Technical information
USB chargers
Area of application
USB chargers allow you to quickly charge the battery of a
portable device without a mobile charger
Use
                                                                                              ≥ 30.8 mm
                      MADE IN CHINA
                      1617 NVE        revA
                 N / L2
100 - 240 V
                 L / L1
Technical information
In-wall bluetooth audio receivers
output
                                                                                                            input
usiness purposes, home
●● Each module has its own identification number to avoid
interference from other users nearby
●● It can be also connected to any device without bluetooth
using the AUDIO IN option
●● It can be connected to two or more speakers of any model,
type and brand available in the market.
Characteristics
Audio receiver:
● communication network type: bluetooth
● operating distance: 10 m
● connector type: jack 3.5 mm
● input impedance: 62 Ω
● rated operational voltage: 15-16 V DC
● current consumption: 4.5-100 mA
● signal isolation: 58 dB
output
                                                                                           input
● bandwith: 45-20 000 Hz
● signal to noise ratio: 84 dB
● number of addresses: 0000-9999
● transmission frequency: 2.4 GHz
● radio power: 7 dBm
● connection terminals: screws terminals
● degree of protection: IP20
                                                                Embedding depth
Power supply:
● rated operational voltage: 265 V AC
● network frequency: 47-63 Hz
● consumption demand: 12 W
● input voltage: 100 mV rms with jack
● output voltage: 15 V DC
● output current: 800 mA
● nominal output power:
○ 2.5 W, 0.8 A, 15 VDC, 8 Ω                                       ≥ 32 mm
○ 1.5 W, 0.8 A, 15 VDC, 16 Ω
● connection terminals: screws terminals
● degree of protection: IP20
Loudspeakers:
● 2 loudspeakers delivered with 2 cables (5 m, Φ 0.5 mm2, red
and white)
● dimensions (diameter x depth): 95 mm x 36 mm
● input impedance: 8 Ω
Technical information
In-wall bluetooth audio receivers (cont’d)
Use
                                    Bluetooth ID
15 Vdc
Pair Connected
Technical information
Telephone sockets
Technical data
● 4 to 6-pin connectors (RJ11 and RJ12 respectively)                                                        RJ11/RJ12
with screw connection or insulator displacement.
These connectors are Category 3, implying transmission rates    Screw connection system
of up to 16 Mb/s.
● The standard line with 1 pair of wires is connected between   Connection terminals: screw connection for rigid cables up to 0.2 mm2.
                                                                				
L1 and L2 connection of RDSI, ADSL lines and other 4-wire
lines (two pairs) is found between L1-L2 and TX-TS.
TX TS TX TS TX TS TX TS
T 2 T 2 T 2 T 2
L2 L1 L2 L1 Phone L2 L1 L2 L1
                                                                Dimensions
                                                                Screw connection	                  Connection by insulator displacement
                                                                              12                                 26
                                                                         23                                 36
Technical information
Indicator lamps
Technical data
Incorporates a neon bulb, ref. MGU0.821.
Standards
In accordance with LV and EMC directives.                      Dimensions (mm)
31
44
Technical information
Buzzers
MGU3.785.XX
Area of application                                           Volume setting
● This product is used as a call signal at the entrance
to homes, offices and businesses or to indicate an alert
in technical alarm systems (intermittent operation).
● With adjustable volume.
Technical data
● Rated voltage: 230 V AC ± 10 %, 50-60 Hz.
● Volume can be adjusted using a screw located on the side.
● Acoustic output: between 76 and 80 dB.
● Consumption: 40 mA.
● Maximum continuous operation time: 60 s.
Standards
In accordance with LV and EMC directives.
                                                              Connections
                                                              ● Terminal identification: L (phase), N (neutral)
                                                              ● Connection terminals: screw connection for cables up to 2 x 1.5 mm2.
Dimensions (mm)
31
42
Technical information
Electronic bells
MGU3.786.XX
Area of application                                               Use
● It is particularly appropriate for homes, offices and so on,    The bell has 3 different inputs for the various push-buttons. 5 melodies are provided
where it is necessary to distinguish between someone ringing      and a different one can be programmed for each input (see Melody selection programming).
from outside the building and an internal service bell
(for example the electronic door control for the whole building   Melody selection programming
and the entrance door).                                           ● Press the button for 15 s to access the melody programming mode. The bell plays all
                                                                  the available melodies in turn until you press briefly to make your choice. If no melody has
                                                                  been selected within approximately 3 minutes, the bell returns to its initial state and the original
Technical data                                                    melody remains unchanged.
● Rated voltage: 230 V AC ± 10 %, 50-60 Hz.                       ● Different melodies can be selected for the other bell inputs (push-buttons).
● Number of programmable melodies: 5.
● Conventional push-buttons with or without indicator lamp        Connections
can be used for electonic bell:
○ maximum number of push-buttons connected in parallel
without indicator lamp: 10,
○ maximum number of push-buttons connected in parallel
with indicator lamp: 3.
● Acoustic output: 70 db/ 1 m.
● Consumption: 14 mA.
Standards
In accordance with IEC 62080.
                                                                                  *
                                                                  L
                                                                  N
                                                                  * Use of a maximum of 10 push-buttoms without indicator lamp connected in parallel
                                                                  or 3 push-buttoms with indicator lamp connected in parallel.
                                                                  ● Connection terminals: screw connection for cables up to 2 x 1.5 mm2.
Dimensions (mm)
                                                                                  33
                                                                             44
Technical information
Emergency lights
MGU3.776.T
Area of application                                                Connections
Emergency lighting should the electrical power supply fail in
the residential and tertiary sectors, for lighting of stairways,
corridors and premises open to the general public.
                                                                                   - 3.776.T
Technical data                                                                     230 V~
                                                                                   50 HZ
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Battery charging: 24 h.
● Autonomy: 1 h.                                                                                   L N
● Green LED: On indicates connection to the electrical
network and that the battery is in charging phase or fully
charged.                                                           L
● Green LED: Off indicates that the battery is not being
                                                                   N
charged.
● Transparent diffuser.                                            Connection terminals: screw connection for cables up to 2 x 2.5 mm2.
● Battery life: 500 cycles.
● Bulb life: 400 h.
● Bulb and battery cannot be replaced.
● Brightness with diffuser/distance: 45 lux/ 25 cm.
                                                                   Dimensions (mm)
Standards
In accordance with EN 60598-2-22 concerning emergency
lighting and with LV and EMC directives.
                                                                                  33
                                                                             44
Technical information
Autonomous pilotlamps
MGU3.780.T
Area of application                                                   Use
Emergency lighting should the electrical power supply fail            1                     2                      3                          4
in the residential and tertiary sectors, for lighting of stairways,                                                                    ON
corridors and premises open to the general public.
Technical data
                                                                                                                                                     OFF
● Rated voltage: 230 V AC ± 10 %, 50 Hz.
● Luminous flux: 2 lumens.
● Autonomy: 3 h.                                                      ● The autonomous pilotlamp (MGU3.780.T) is connected to the electrical network.
● Batteries: 2 x 1.2 V - 0.3 Ah.                                      When the latter is energised, a green LED lights up on the autonomous pilotlamp (drawing 1).
● Minimum charging time: 24 h.                                        In event of a power cut, the pilotlamp remains lit by means of 2 yellow Leds (drawing 2).
● Impact strength: IK07.                                              The autonomous pilotlamp has an autonomy of 3 h.
                                                                      ● If the electrical network is energised and the green LED is not lit, this means that the battery
Standards                                                             is completely discharged. The product must then be replaced.
                                                                                      33
                                                                                 44
Technical information
Fixing frames
                                3
                                4
                                5
                                                                       MGU7.012.GLS            MGU7.892.A
                                                                                              60
                                                   3                     7                    75
Technical data
● Material: Zamak (zinc and aluminium alloy) or plastic                                                          41 71
(technopolymer) of very high rigidity and completely rustproof,
thus making it resistant long-term and to cleaning products
(javel water, ammonia solution, etc.).
● It is ready for insertion of cover frame rack type guides,
thus providing a solution for wall irregularities and ensuring
proper fastening, including :                                                                  41
○ when the box remains sunk in to up to 2.5 mm on the wall                                     71
○ when the box projects by 0.75 mm from the wall.
                                                                         11
● Ergonomic design: it exhibits no sharp edges, burr
                                                                       Universal fixing frame without claws (2 gang)
or cutting parts that could be harmful during installation.
● Easier fixing frame alignment thanks to two points:
○ a dovetail system for perfect coupling (for the universal
fixing frame)
○ a straight surface to facilitate use of a boning rod.
                                                                                                                                          71
Standards
In accordance with EN 60669-1.
                                                                                                              71
                                                                         7                                   142
Technical information
Fixing frames (cont’d)
Dimensions (mm)
Italian fixing frames
                              A
53 44 70
9 C
44 57 60.6
9 71
44 57 60.6
4 71
57
Technical information
Surface mounting boxes
                                                                                                       71
Dimensions (mm)
1 gang surface mounting box                                        3 gang surface mounting box (Unica Colors, Unica Basic)
(Unica Colors, Unica Basic)
                                                                                                                                36
                                36
                                                                                             195
                                                                                   71
              41
                                                                           46                                                49 80
46                         50        80
             55                                                                         227
             85
                                                                   Italian surface mounting boxes (Unica Allegro)
                                                                                                                 36
2 gang surface mounting box
(Unica Colors, Unica Basic)
                                                                                        40
36
                                                                   46                                       51 80
                     122
             41
                                                                                                                                       A (mm)   B (mm)
                                                                                                                         3 modules     82       116
                                                                                        A
                                                                                        B                                4 modules     104      139
46                                           50 80
                                                                   Complete assemblies (Unica Basic, Unica Color)
                                                                   1 gang surface mounting box	         2 gang surface mounting box
                                                                   (cover and fixing frame)	            (cover and fixing frame)
                     156
                                                                      36                     65                         125
65 65
Technical information
IP55 surface mounting boxes
Technical data                                                                                                                   25 38
● Tightness level: IP55.
● Impact strength: IK07.
                                                                                          22 40 48 73
● Cables enter via adjustable membranes.
● Cable inlets are 6 to 21 mm in diameter.                                                                      60
● Easy, quick installation by closing bolts.                                                                    73
● Many wall-mounting points.
                                                                          38
Standards                                                                 48
In accordance with EN 60529-91 + E: 93.                                   58
22 40 48 73
                                                                          38          20
                                                                                      73
                                                                         58                         48
                                                                                                               25 38
IP55 double vertical box (2 gang)
                60
                                                                         60           18            60
                                                                                       150
                              25 38
                                                                IP55 triple horizontal box (3 gang)
22 40
73                               38 150                                  38                               20         58
                                                                                     78                   78
22 40 48 25 38
                                                                         60          18           60      18         60
                38                                                                                 228
                48
                58
                73
Technical information
Flush mounting boxes
1 41 1 41
119
135
158
135
182
74
                                              48                                108
                                                                                131
74
                                              48                           83,5
                                                                           106
50
Technical information
Cover frames
Technical data
● All Unica finishes are resistant to cleaning products                                                   E
and UV radiation.
● Recyclable thermoplastic materials.
● Self-extinguishing thermoplastic materials with excellent
impact strength.
● The Unica Top range incorporates Zamak cover frames
with electroplating and finishes made of natural wood, not                                                                                                            A
deformable, having undergone an anti-fungal treatment.
● Cover frames are mounted by means of rack type guides
eliminating wall irregularities in vertical position:
○ when the box remains sunk in to up to 2.5 mm on the wall.
                                                                                                              F
○ when the box projects by 0.75 mm from the wall.
90 90
85 156
3 gang
90
227
Technical information
Cover frames (cont’d)
75 143
35 68
35
A A
14 B C
A A
D E
Technical information
Cover frames (cont’d)
80 80
                                                                                                          B                            71
14                 A                           B                                                     71
                                                    80                                                                                 71
                                                                                      80
                                                                                                                         80
                                                                  80
                                                                             1 gang          2 gang             3 gang        4 gang
                                                                             A (mm)          B (mm)             C (mm)        D (mm)
                                                                             90              161                232           303
                                D
57 147 57
204
57
80
80
Unica Top, cover and fixing frame for thin panel Unica Top and Unica Plus (Italian)
1 module 1 + 1 modules
A A
75 143
                                                           14                B                                           C
     35                      68
                                                                            A (mm)         B (mm)         C (mm)
                                                           3 modules        80             118
                                                           4 modules        80                            140
35
Technical information
Cover frames (cont’d)
90 90
85 156
3 gang
90
227
155 175
 16                     152
                                                              195
Unica Plus, IP44 cover and fixing frame (with or without claws)
          1 gang
80
30 90
90 90
30 126 30 149
Technical information
Cover frames (cont’d)
Unica Class
93 93
11 A B
93
93
Unica Wireless
Wireless comfort
Unica Wireless is a range of wireless products which use radio technology (RF)
to exchange information. The products are highly suitable for refurbishment
work in residential and small building environments without damaging the
walls.
They make it considerably easier and far more pleasant to control lighting
and roller blinds in the home. They are simple to install and program.
                                                                                                                                             Receivers
                                                                                                                                             Receivers control the load
                                                                                                                                             that is plugged to them
                                                                                                                                             (table lamp, ceiling lamp, etc.)
                                                                                                                                             and are controlled by the
                                                                      Combined modules
                                                                                                                                             emitters.
                                                                      They are connected instead of the existing switches.
                                                                      The key is used for local control; when a second key is mounted it
Emitters                                                              can be used as an emitter to pilot another wireless receiver.
Emitters are battery-operated and can be screwed or stuck
wherever you wish to add a control point, without connecting them
to the mains supply.
                                                             Integration of an emitter:
                                                             ● The emitter is supplied with a flat integrated fixing frame.
                                                             ● It can be easily glued or screwed on any type of wall.
                                                                              +                 +                      =
Simplified programming
Emitters and receivers are linked by simple                  1 fixing frame    1 combined module      1 cover frame            1 Unica wireless solution
programming.
                                                             Technical advantages
                                                             ● Unica Wireless products have an outdoor range of 300 m and an indoor range
                                                             of 10 to 50 m. For battery-powered products, the wireless technology link has been
                                                             optimised to extend the life of the battery (5 to 7 years, depending on its use).
Battery-powered push-button         Combined module
                                                             ● There are two possible programming modes:
The rockers can be removed to access the                     ○ The Control mode is used to set up a link between emitters and receivers
programming keys.                                            for simple control function (on, off, dim).
                                                             ○ The Scenario mode allows you to link with a particular button the lighting
                                                             atmospheres you have created.
To link wireless products, simply:
                                                             ● The kit of rockers supplied permits to have 1 or 2 keys, depending on the
● Press the «A» key on the emitter.
                                                             application. It is also a good way to start with a simple application (one key)
● Press the pole (1, 2, etc.) on each emitter.               and then upgrade to a more sophisticated application, by simply moounting 2 keys.
● Press the «A» key on the receivers.                        ● The symbols on the rockers can be easily removed and replaced.
● Finally, press the «A» key on one of the products.         ● The programming is not lost when you change the battery (or during a mains
                                                             power failure).
Personalize
                                                     Initial situation
                                                     In the bedroom, the ceiling lamp is controlled by a single switch.
                                                     Requirement
                                                     Add switches to control the lighting from the head of the bed.
                                                     The disadvantages
                                                     ● Wires, cables and shields have to be drawn through the wall.
                                                     ● Dust and damaged walls.
                                                     ● Lengthy, tedious and expensive work.
                                                     ○ Cabling has to be installed (wires, cable, shield).
                                                     ○ Cabling has to be changed.
The advantages
● Quick and easy to install.
● No damage.
● Most affordable solution.
Optional functions
● Use a combined dimmer to add the «dimming»
function.
● Add a remote control.
● Control bedside lamps from the main switch,
by adding a mobile socket outlet.
Change of atmosphere
                                                                 Initial situation
                                                                 Each light has its own mechanical switch.
                                                                 Requirement
                                                                 Create scenarios to control the lighting atmosphere at the touch of a single button.
                                                                 Scenario 1
                                                                 «cooking»
      A
                                                                 A program that can be set to switch on the kitchen and dining lighting at the same
                        B              A                         time:
                                                                 Scenario 2
                                                                 «watching television»
      A
                                       A                         A program that can be set to adapt the lighting for watching television:
                        B
                                                                 A- the kitchen wall light is set to 30%
                                                                 B- the dinner table ceiling light is set to 40%
                                                                 Scenario 3
                                                                 «coming home»
                                                                 A program that can be set to switch on the various lights that have been preset for
                                                                 when you arrive home.
Note: the scenario should always include a function that switches off all the lights.
                                                                 Scenario 4
                                                                 «going out/all lights off»
Battery-powered push-buttons with set of symbold for scenarios   A program that can be set to switch off all the lights.
                                                                 Optional functions
                                                                 ● Add a remote control.
                                                                 ● Add the roller blind control to a scenario.
                                                          Initial situation
                                                          Each electric blind has its own individual control. You have to go from one blind
                                                          to another to close them.
                                                          Requirement
                                                          Open or close all the roller blinds with just one button.
                                                          The disadvantages
                                                          ●● Wires, cables and shields have to be drawn through the wall.
                                                          ●● Dust and damaged walls.
                                                          ●● Lengthy, tedious and expensive work.
                                                          ●● Cabling has to be installed (wires, cable, shield).
The advantages
●● Simple, quick and less expensive to install.
●● No damage.
●● One of the wireless modules for roller blinds can be
used as the centralised control (using the second key).
Optional functions
Add a remote control.
(1) Universal: controls the main types of lamps with dimmable lighting; with auto-detection of the type of lamp.
Accessories
                                  Test kit                                     Two identical products to test the signal strengh between two    CCT1A090
                                                                               locations.
                                                                               The led indicates the reception level: green, orange, red.
                                                                               Supplied in a mini-suitcase.
(1) Universal: controls the main types of lamps with dimmable lighting; with auto-detection of the type of lamp.
Technical information
Battery powered push-buttons
MGU84.071.XX - MGU86.071.XX - MGU88.071.XX
Area of application                                                 Advantages
The Unica wireless battery-powered push-buttons are used to         ● You can easily convert a wired one-way switch into a two-way switch.
control Unica wireless receivers for both light and roller blinds   ○ Just replace it with a combined relay (or combined dimmer) and add one or more battery-
such as; combined modules and mobile socket outlets.                powered push-buttons.
                                                                    ○ The conversion does not require any rewiring or other work that will damage the room (walls,
Technical data                                                      wallpaper, paintwork, etc.). It can all be completed in just a few minutes, without any dust and
● Transmission frequency: 868 MHz.                                  without moving any furniture.
● Transmission distance: up to 300 m outdoor and typically          ● It takes just a few moments to add an extra control point.
10-50 m indoor (depending on the construction material).            ● You can mount the 2 modules cover on the battery powered push-button device to control one
● Battery: 3 V button battery, CR2032 type.                         receiver and you can easily replace the 2 modules cover by two 1 module covers to control other
● Battery life time: depends on use, usually between 5 and 7        receivers.
years (approximately 20,000 operations at 20°C).
● Operating temperature: - 5°C to + 50°C.
● Humidity: 20% - 95% without condensation.
● Protection class: IP 20.                                          Installation
                                                                    ● They can be screwed or stucked directly onto the wall (with glue, adhesive tape, etc.);
                                                                    they can be installed anywhere in the house: at the end of the bed, in a corridor and on all types
Standards                                                           of materials (glass, wood, etc.).
In accordance with:                                                 ● Each push-button can be programmed in Simple mode or Scenario mode using the supplied
● EN 61000-6-2, EN 61001-6-3.                                       set of symbols for t he various functions.
● ETSI EN 300220, ETSI EN 301489.
● EMC directive: 89/336/EEC.
● R&TTE directive: 99/5/EEC.
                                                                    Programming
                                                                    Programming operation follows the same principles as described in the «Unica wireless system»
                                                                    part.
Dimensions (mm)
                                                                             5
                                                                      19                              A
                                                                                                       A (mm)      B (mm)
                                                                     Unica Colors, Unica Basic         80          80
                                                                     Unica Top, Unica Plus             90          80
                                                                     Unica Class                       96          88
Technical information
Universal emitter
CCT1A030
                                                                Connections
                                                                ● If only 1 function is needed (e.g. on/off), only connect the pairs E1 and E2 to push-buttons.
                                                                ○ The push-button connected to pair E1 will be used for ON (or dim-up with a long push
                                                                for a dimmer).
                                                                ○ The push-buttons connected to pair E2 will be used for OFF (or dim-down with a long push
                                                                for a dimmer).
                                                                ● If 2 functions are needed, connect also E3 and E4 to 2 push-buttons.
Antenna
                                                                Input E4: blue and white-blue cables, input E3: brown and white-brown cables,
                                                                input E2: green and white-green cables, input E1: red and white-red cables.
                                                                Dimensions (mm)
                                                                ● H x W x D : 42 x 40 x 12 mm without cables.
                                                                ● Cables length: 270 mm.
12 40
Technical information
Metal remote control
CCT1A000
Area of application                                             Advantages
● The Unica metal remote control is used to remotely control
the Unica wireless receivers and comnined modules.              ● The metal remote control can be customized via its set of 32 keys containing
● Its elegant design and particularly stylish finish makes it   a large number of symbols.
a decorative object that can be left in full view on a piece    ● Its keys can be fitted for vertical or horizontal use to control the lighting and roller blinds.
of furniture.                                                   ● The metal remote control is supplied with:
                                                                ○ 32 keys with symbols.
                                                                ○ 2 AAA (LR3) batteries.
Technical data
● 8 channels which can be programmed in Simple
or Scenario mode.                                                                                                      3       4
● Transmission frequency: 868 MHz.
● Transmission distance: 300 m outdoor and typically                                                                   5       6
10-50 m indoor (depending on the construction material).
● Battery: 2 AAA (LR3) batteries (2 batteries supplied).                                                               7       8
● Operating temperature: - 5 °C to +50 °C.	
● Humidity: 20% - 95% without condensation.
● Protection class: IP 20.
                                                                                                       1        2
                                                                Dimensions (mm)
                                                                   15
13
170
Technical information
Keyring remote control
CCT1A010
Area of application                                            Advantages
● The Unica keyring remote control is mainly designed
to remotely control the utilities in a bedroom or office.      ● The keyring remote control is small enough to slip easily into a pocket.
Each member of the family can have one to control the lights   ● Its original, ergonomic design ensures that it is convenient and pleasant to use.
and roller blinds in their room.                               ● Its metal ring allows it to fit onto a key ring.
● It can also be used to control the outdoor lighting,
the garage door or the front gate of the house.
Technical data
● 4 channels which can be programmed in Simple or Scena-
rio mode.
● Transmission frequency: 868 MHz.
● Transmission distance: up to 300 m outdoor and typically
10-50 m indoor (depending on the construction material).
● Battery: 3 V battery, CR2032 type (1 battery supplied).
● Battery life time: depends on use, usually between 5 and 7
years (approximately 20,000 operations at 20°C).
● Operating temperature: - 5 °C to +50 °C.                     Dimensions (mm)
● Humidity: 20% - 95% without condensation.
● Protection class: IP 20.
                                                                   12                         44
Standards
In accordance with:
● EN 61000-6-2, EN 61001-6-3, IEC60068-2-6,
IEC60068-2-27.
● ETS300220-1, ETS300220-2.                                                                                       46
● EMC directive: 2004/108/EC.
● R&TTE directive: 99/5/EEC.
11
Technical information
Combined relays
MGU3.572.XX - 2300 W
Area of application                                               Advantages
● The Unica wireless combined relays contain both an emitter      ● You can easily convert a wired one-way switch into a two-way switch.
and a receiver.                                                   Just replace it with a combined relay and add one or more battery-operated push-buttons.
● Each combined relay can replace an existing switch to           ● You can choose to use the combined relays:
control a lamp locally or remotely (via a battery-powered push-   ○ To control only the connected load, using the large cover (2 modules).
button or via the remote control).
                                                                  ○ To control both the connected load and other Unica wireless receivers such as mobile
                                                                  socket-outlets, using the 2 narrow covers (2 x 1 module covers).
Technical data
● Rated voltage: 110-230 V AC ± 10 %, 50-60 Hz.
● Transmission frequency: 868 MHz.
                                                                  Installation
                                                                  ●● The combined relays can be installed:
● Transmission distance: up to 300 m outdoor and typically
                                                                  ○ In flush-mounted box at least 40 mm deep with an universal Unica fixing frame with or without
10-50 m indoor (depending on the construction material).          claws.
● Protection: 10 A fuse.                                          ○ In Unica surface-mounted boxes.
● Operating temperature: - 5 °C to +50 °C.
● Humidity: 20% - 95% without condensation.
● Protection class: IP 20.
Load table
          1    2      3       4     5    6     7
 25 °C
 230 V                                                            ● The Unica wireless combined relay is supplied with:
 50 Hz
                                                                  ○ 2 narrow covers (1 module covers).
 Max.
                                                                  ○ 1 large cover (2 modules cover).
 W/VA    2300 2000   500     920 880 880 690
                                                                  ○ A set of 8 symbols to customize the covers ( 2 symbols «1/0» and 2 symbols «dimmer-up/
                                                                  dimmer-down»).
1 - Incandescent lamps
2 - Halogen lamps
3 - Low voltage halogen lamps with ferromagnetic transformer
                                                                  Programming
                                                                  Programming operation follows the same principles as described in the «Unica wireless
or with toroidal transformer or with electronic transformer       system» part.
4 - Fluorescent tubes dia. 28 or 38 mm
5 - Compact fluorescent lamps
6 - LED lamps                                                     Connections
7 - Motors and ventilators
                                                                  L                                                           N
Standards
In accordance with:                                                                    110-230V~
● EN 60669-1, EN 60669-2-1.
● ETSI EN 300220, ETSI EN 301489.
● EMC directive: 89/336/EEC.
● LVD directive: 73/23/EEC.
● R&TTE directive: 99/5/EEC.
Dimensions (mm)
                                                                                  34
                                                                             46
Technical information
Combined relays
MGU3.572.XX - 2300 W
Area of application                                            Advantages
● The Unica wireless combined dimmers contain both
                                                               ● You can easily convert a wired one-way switch into a two-way switch.
an emitter and a receiver.
                                                               Just replace it with a wireless combined dimmer and add one or more battery-operated push-
● Each combined dimmer can replace an existing switch
                                                               buttons.
to control a lamp locally or remotely (via a battery-powered
push-button or via the remote control).                        ● You can choose to use the wireless combined dimmer:
● They allow to create soft lighting atmospheres and saving    ○ To control only the connected load, using the large cover (2 modules).
energy as they reduce the current supplying the load.          ○ To control both the connected load and other Unica wireless receivers such as mobile socket-
                                                               outlets, using the 2 narrow covers (2 x 1 module covers).
Standards
In accordance with:
● EN 60669-1, EN 60669-2-1, EN 61000-6-2, EN 61000-6-3.
● ETSI EN 300220, ETSI EN 301489.
● EMC directive: 89/336/EEC.
● LVD directive: 73/23/EEC.
● R&TTE directive: 99/5/EEC.
Dimensions (mm)
                                                                                34
                                                                           46
Technical information
Combined roller blinds
MGU3.574.XX
Area of application                                                   Advantages
● The Unica wireless combined roller blinds are used to
remotely control the opening and the closing of all the roller        ● A centralised roller blinds control can be created without any rewiring and requires no repair
blinds in a room (or house).                                          work: no damaged walls, wallpaper, paint, etc. It can all be completed in just a few minutes,
● They are typically used to create centralisation of roller blinds   without any dust and without moving any furniture.
without new wires or holes.                                           ● Just replace each existing individual wired control with a Unica wireless combined roller blind
                                                                      module, then add Unica battery-powered push-button for centralised control in the required
                                                                      position.
Technical data
● Rated voltage: 110/230 V AC ±10%, 50-60 Hz.
● Transmission frequency: 868 MHz.                                    Installation
● Transmission distance: up to 300 m outdoor and typically
10-50 m indoor (depending on the construction material).              ● The wireless combined roller blinds can replace an existing mechanical roller blinds control.
● Protection: protection against one shot overload with ther-         ● You can choose to use the wireless combined roller blinds:
mofuse and with main fuse 10 A.                                       ○ To control locally the connected roller blind, using the large cover (2 modules).
● Operating temperature: - 5 °C to +50 °C.                            ○ To control both; locally the connected roller blind and remotely other roller blinds,
● Humidity: 20% - 95% without condensation.                           using the 2 narrow covers (2 x 1 module covers). Centralised control can therefore be created in
● Protection class: IP 20.                                            just a few minutes.
● Maximum load: 690 W, single phase tubular motors for roller         ● The combined roller blinds can be installed:
blind (with or without limit switches).
                                                                      ○ In flush-mounted box at least 40 mm deep with an universal Unica fixing frame with or without
                                                                      claws.
Standards                                                             ○ In Unica surface-mounted boxes.
In accordance with:
● EN 60669-1, EN 60669-2-1.
● ETSI EN 300220, ETSI EN 301489.
● EMC directive: 89/336/EEC.
● R&TTE directive: 99/5/EEC.
                                                                      Programming
                                                                      Programming operation follows the same principles as described in the «Unica wireless system»
                                                                      part.
                                                                      Connections
                                                                      L                                                                N
Dimensions (mm)
                                                                                       34
                                                                                  46
Technical information
Mobile socket-outlet relays
CCT1A020 (german type) - CCT1A022 (french type)
Area of application                                               Advantages
● The Unica wireless mobile socket-outlet relays are used
to remote control the lamps or devices connected to them.         ● You can switch all the lamps connected to a socket on or off in one go.
● They can be linked with the other Unica wireless products       ● The lamps can be operated (switched on, off) locally via the key located on the mobile socket-
by simple programming.                                            outlet or remotely by using Unica battery-powered push-button or Unica remote controls.
● They are appropriate for use with all standard sockets fitted   ● You can include your decorative lamps, halogen lamps, etc. in your Scenarios.
at home.
Technical data
● Rated voltage: 230 V AC ±10%, 50 Hz.
● Transmission frequency: 868 MHz.
● Transmission distance: up to 300 m outdoor and typically
10-50 m indoor (depending on the construction material).
● Operating temperature: - 5 °C to +50 °C.
● Humidity: 20% - 95% without condensation.
● Protection class: IP 20.
Load table
                                                                                                                                Programming keys
             1         2          3   4   5    6
 25 °C
 230 V                                                            French type                      German type
 50 Hz                                                            mobile socket-outlet relay       mobile socket-outlet relay
 Max.
 W/VA    2300        1840    1840 1840 1840 1380
111
Technical information
Mobile socket-outlet dimmers
CCT1A021 (german type) - CCT1A023 (french type)
Area of application                                               Advantages
● The Unica wireless mobile socket-outlet dimers are used
to remote control the lamps or devices connected to them.         ● You can switch all the lamps connected to a socket on or off in one go.
● They can be linked with the other Unica wireless products       ● The lamps can be operated (dimmed, switched on, off) locally via the key located on the
by simple programming.                                            mobile socket-outlet dimmer or remotely by using Unica battery-powered push-button or Unica
● They are appropriate for use with all standard sockets fitted   remote controls.
at home.                                                          ● You can include your decorative lamps, halogen lamps, etc. in your Scenarios.
● They allow to create soft lighting atmospheres and saving
energy as they reduce the current supplying the load.
Technical data
● Rated voltage: 230 V AC ± 10%, 50 Hz.
● Transmission frequency: 868 MHz.
● Transmission distance: up to 300 m outdoor and typically
10-50 m indoor (depending on the construction material).
● Protection: electronic, against overloads, temperature rises,
short-circuits and damage from inappropriate loads.
● Operating temperature: - 5 °C to +35 °C.
● Humidity: 20% - 95% without condensation.                                                                                 Programming keys
● Protection class: IP 20.
Load table
                                                                  French type                     German type
             1        2       3     4     5     6                 mobile socket-outlet dimmer     mobile socket-outlet dimmer
 25 °C
                                                                  Programming
 230 V                                                            Programming operation follows the same principles as described in the «Unica wireless
 50 Hz                                                            system» part.
 Max.
 W/VA     250        250     NO NO NO NO
1 - Incandescent lamps or halogen lamps                           Dimensions (mm)
2 - Low voltage halogen lamps with ferromagnetic transformer
or with electronic transformers                                             73                                       51
3 - Fluorescent tubes dia. 28 or 38 mm
4 - Compact fluorescent lamps
5 - LED lamps
6 - Motors and ventilators
Standards
In accordance with:
● IEC 60669-1, IEC 60669-2-1, IEC 61000-6-2, IEC61000-6-3.                                            111
● ETSI EN 300220, ETSI EN 301489.
● EMC directive: 89/336/EEC.
● LVD directive: 73/23/EEC.
● R&TTE directive: 99/5/EEC.
Technical information
Universal receiver relay
CCT1A031 - 2300 W
Area of application                                                  Advantages
The Unica wireless universal receiver relay is used to switch
an electrical load (ceiling lamp, fan, etc.). It receives wireless   ● The universal receiver allows all types of electrical appliances to be remotely controlled.
control orders from wireless emitters or combined modules.           ● It can be hidden in the installation to preserve the aesthetic appearance of the room.
                                                                     ● You can easily separate two lighting points to allow them to be controlled separately.
                                                                     Just fit a wireless universal receiver at each lighting point, then use Unica wireless products to
Technical data                                                       control them such as; battery-powered push-button, universal emitter or remote control.
● Rated voltage: 127/230 V AC ± 10%, 50/60 Hz.                       ● It takes just a few moments to add an extra control point.
● Transmission frequency: 868 MHz.
● Transmission distance: up to 100 m outdoor and typically
10-50 m indoor (depending on the construction material).             Installation
● Protection: protection against one shot overload                   ● The universal receiver can be mounted in various ways:
with thermofuse and with main fuse 10 A.                             ○ Flush-mounted in the ceiling in a box with a minimum depth of 40 mm.
● Operating temperature: - 5 °C to +50 °C.                           ○ Concealed in the base of a ceiling light. A hook can be passed through the hole in the centre to
● Humidity: 20% - 95% without condensation.                          fix the lamp.
● Protection class: IP20.                                            ○ Concealed in a suspended ceiling.
                                                                     ○ In a flush wall-mounted box, behind a blanking plate.
Load table                                                           ● Metal surfaces near the receiver may affect reception.
Minimal load: 5 W.                                                   ● It is easy to program via the programming keys.
                                                                     ● It has no control button: it can only be remote controlled.
          1    2       3        4     5     6     7
 25 °C
                                                                     Connections
 230 V
 50 Hz
 Max.                                                                L                                                              N
 W/VA    2300 2000    500      920 880 880 690                                                          ANT
1 - Incandescent lamps
                                                                                                    A
2 - Halogen lamps
3 - Low voltage halogen lamps with ferromagnetic transformer                               ON/OFF
Standards
In accordance with:
● EN 60669-1, EN 60669-2-1, EN 61000-6-2, EN 61000-6-3.
● ETSI EN 300220, ETSI EN 301489.
● EMC directive: 89/336/EEC.                                         Dimensions (mm)
● R&TTE directive: 99/5/EEC.                                         ● H x W x D : 46 x 46 x 23 mm without cables.
                                                                     ● Cables length: 200 mm.
46
23
Technical information
Test kit
CCT1A090
Area of application                                              Installation
The Unica wireless Test kit is used to test the transmission     ● The Unica wireless test kit is supplied with 2 identical products to be used by pair
quality of the radio signal.                                     (1 emitter, 1 receiver).
                                                                 ● Place the Unica test devices in the various rooms where the equipment is to be installed
                                                                 to check the quality of the radio signal link.
Technical data
● Transmission frequency: 868 MHz.
● Transmission distance: up to 300 m outdoor and typically
10-50 m indoor (depending on the construction material).
● Battery: 3 V battery, CR2032 type, supplied with 2 batteries
(one for each testing device).
● Battery life time: depends on use, usually between 5 and 7
years (approximately 20,000 operations at 20°C).
● Operating temperature: - 5 °C to +50 °C.
● Humidity: 20% - 95% without condensation.
● Protection class: IP 20.
                                                                 3 LED indicate the radio signal reception level (green, orange, red).
Standards
In accordance with:
● EN 61000-6-2, EN 61001-6-3.                                    Dimensions (mm)
● ETSI EN 300220, ETSI EN 301489.
● EMC directive: 89/336/EEC.
● R&TTE directive: 99/5/EEC.
63
11 63
Technical information
Programming
Introduction
● The Unica wireless system is used for wireless control of lamps and other electrical equipement.
● The system consist of emitters, receivers and combined modules containing both emitters and receivers.
● The Unica wireless products can be programmed and thus linked with 2 different programming modes:
○ Simple mode programming.
○ Scenario mode programming.
● Each time you program a function between an emitter and a receiver you create a link. Unica wireless products can contain up to 32 links, except the combined
modules which can contain up to 64 links.
                                                                                              60%
                 Dim up /
                 Switch on
100%
                Dim down /
                switch off
                                                                                              40%
Example of “simple mode” for light dimming
                                                                   Example of “Scenario mode” for dinner
The covers (2 modules or 2 x 1 module) have to be removed
to acess to the programming keys and the emitters have to          The covers (2 modules or 2 x 1 module) have to be removed to acess to the programming keys
be programmed before the receivers.                                and the emitters have to be programmed before the receivers.
3 1 3 1 3 1 3 1
A A A A
B B B B
4 2 4 2 4 2 4 2
Start the programming by          Before 5 s, select the           Start the programming by          Before 5 s, select a key:
pressing the programming          decided pair of keys: Press 3    pressing the programming          Press 1or 2 to select the top or bottom part of the right side.
button A once.                    or 4 to select the left side     button A twice.                   or press 3 or 4 to select the top or bottom part of the left side.
LED B lights up red.              (it makes no difference          LED B lights up green.            LED B flashes green.
                                  whether you press 3 or 4),       Repeat this operation on other emitter(s) if needed.
                                  or press 1 or 2 to select the
                                  right side. LED B flashes red.
                                                                   Receiver(s) programming
Repeat this operation on other emitter(s) if needed.
                                                                         1                                                                      1
Receiver(s) programming                                                                                    1
                                                                         A                                                                      A
      1                                 1                                                                  A
                                                                         B                                                                      B
      A                                 A                                                                  B
      B                                 B
                                                                         2                                                                      2
                                                                                                           2
                                                                                                               0%             100%
      2                                 2                          Select the receiver by            If the receiver has a dimmer         Finish the programming
                                                                   pressing the programming          function, set the desired            by pressing programming
                                                                   button A once.                    level using buttons 1 or 2.          button A of any receiver.
Select the receiver by            Finish the programming by        Wait until LED B flashes                                                All LEDs are switched off.
                                                                                                     If the receiver has a relay
pressing the programming          pressing programming             green. (after 5 s with            function, set the state you
button A once.                    button A of any receiver.        a combined module).               want (on/off) by pressing
Wait until LED B flashes red.      All LEDs are switched off.
(after 5 s with a combined                                                                           the same buttons.
module).                                                                                             LED B lights up red for the
                                                                                                     first 5 s and then flashes
Repeat this operation on
                                                                                                     green.
other receiver(s) if needed.
                                                                  Repeat this operation on other receiver(s) if needed.
Technical information
Programming examples (cont’d)
                                        A
                        The battery-powered push-button A can control:
                        ● With the left key, the lamp connected to the mobile socket-outlet B.
                        ● With the right key, the ceiling lamp in the kitchen connected to the combined dimmer C.
                        B
                                                60%                   100%
                                                      D
                                                                             C
                                        A
                        The battery-powered push-button A contain 4 Scenario programs.
                        When the family wants to prepare food, pressing the ”food preparation” symbol will cause:
                        ● The lamp connected to the mobile socket-outlet B to be turned off.
                        ● The ceiling lamp above the dinning table connected to the combined dimmer D to be adjusted
                        to 60%.
                        ● The ceiling lamp in the kitchen connected to the combined dimmer C to be set to 100%.
ON
                        B
                                               100%                   40%
                                                      D
                                                                             C
                                       A
                        In the same way, pressing the ”eating” symbol causes:
                        ● The lamp connected to the mobile socket-outlet B to be switched on.
                        ● The ceiling lamp above the dinning table connected to the combined dimmer D to be adjusted
                        to 100%.
                        ● The ceiling lamp in the kitchen connected to the combined dimmer C to be set to 40%.
                        Finally, when you press the ”I’m home” symbol, all lamps are switched on at full strength;
                        when you press the ”I’m leaving” symbol, everything is switched off.
Unica
for KNX system
Intelligent
and good looking home
Connect Unica
to your KNX system!
                                                                     Reading in your favourite armchair in the evening, watching
                                                                     TV on the sofa or dining with family or friends is all the more
                                                                     comfortable if you don’t have to get up to switch each light,
                                                                     lamp or thermostat on or off individually.
                                                                     By setting up individual scenes – for instance using a Unica
                                                                     multi-function push-button – you can combine a wide range
                                                                     of different functions. Once a scene has been created, it
                                                                     can be started at the push of a button – to create a suitable
                                                                     light mood when watching TV or reading for instance or
                                                                     when leaving the house in the morning. If, when doing so,
                                                                     you want the blinds to be raised, the lights switched off and
                                                                     heating turned down, you can activate the «Not at home»
                                                                     scene and all functions will be executed automatically.
                                  Push-button                                             IR push-button
                                  • Can be used to control lights                         • Can be used to control lights
                                  or roller blinds.                                       or roller blinds.
                                  • The system can be used to                             • Can be controlled by KNX IR
                                  control lights and roller blinds                        remote control.
                                  according to the sunlight when
                                  coupled with a sensor.
               Infra Red (IR) remote control                                                          Class, Top, Plus,       black         MTN570222
               for IR push-button receiver                                                            Colors, Basic
Technical information
Push-buttons
                                                                     	A 	 Status LEDs
Technical data                                                       	B 	 IR receiver (no status LED)
●● Power supply: DC 24 V                                             1-4: 	Button assignment in the ETS
●● KNX connection: bus connecting terminal
●● Display elements:
○○ Status LEDs
○○ 1 programming LED                                                                              A
●● Operating elements:
○○ Control keys                                                                                   B
○○ 1 programming button
●● Ambient operating temperature: -5 °C to +45 °C
●● IR receiver:
○○ Angle of reception: approx. 60°                                                                c
○○ Reception range: Dependent on the IR remote control used
●● IR channels: 9
                                                                     	A 	 Bus connection
●● Type of protection: IP 20
●● Initialisation: The device is ready for operation after 5 to 10   	B 	 Programming LED
seconds.                                                             	C 	 Programming button
Technical information
Movement detector
                                                                                                                                                                 C
                                                                                                               20s       3min
                                                                       4
Standards
                                                                       6
EC guidelines: Low-voltage guideline 2006/95/EEC and EMC
                                                                       8
guideline 2004/108/EC.
                                                                     ●● Install the movement detector laterally with respect to the direction of movement so that the
Software functions                                                   beam paths are intersected as vertically as possible.
Five movement blocks: up to four functions can be triggered          ●● Only mount the movement detector in positions which allow the required area to be monitored
per block. Telegrams: 1 bit, 1 byte, 2 bytes.                        optimally.
Normal operation and surveillance operation, master, slave,
safety pause, disable function. Sensitivity, brightness and
staircase timer can be set using the ETS or the potentiometer.
Two movement sensors: the sensitivity and range can be set
separately for each sensor. Self-adjusting staircase timer.
Dimensions
     22            34                                                ●● In order to ensure continuous monitoring, e.g. of a long hall, the areas of detection have to
                                                                     intersect.
                                                                     ●● Movement detectors can detect all objects that radiate heat. You should select an installation
                                                                     site that will not result in undesired heat sources being detected, such as:
                                                                     ○○ switched-on lights in the area of detection
                                                                     ○○ open fires (such as in fireplaces)
                                                                     ○○ windows where the influence of alternating sunlight and clouds could cause rapid changes in
                                                                     temperature.
                                                                     ○○ larger heat sources (e.g. cars), that are detected through windows.
                                                                     ○○ sunlit rooms with reflecting objects (e.g. the floor), which can be the cause of rapid changes in
                                                                     temperature.
                                                                     ○○ windowpanes heated up by sunlight
                                                                     ○○ dogs, cats, etc.
                                                                     ●● Install movement detectors in a wind-resistant switch box: With switch boxes and pipe cabling
                                                                     systems, a draught at the back of the equipment could trigger the movement detector.
                                                                     ●● Avoid direct sunlight. This can destroy the sensor in extreme cases.
Technical information
KNX room temperature control unit
Software functions
Functions of the room temperature control unit:
●● Controller type: 2-step control, continuous PI controller,                                                    A
switching PI controller (PWM)
●● Output: continuous in the range 0 to 100% or switching ON/
OFF
●● Controller mode:
○○ Heating with one controller output
○○ Cooling with one controller output
○○ Heating and cooling with separate controller outputs
○○ Heating and cooling with one controller output
○○ 2-step heating with 2 control outputs
○○ 2-step cooling with 2 control outputs
○○ 2-step heating and cooling with 4 control outputs                      1      2           3       4
●● Operating modes: Comfort, comfort extension, standby,
night reduction, frost/heat protection                              1 + 4: 	Menu navigation push-buttons
●● Move all setpoints, save all setpoint temperatures and           2 + 3: 	Push-buttons
operating modes when reset, external temperature monitoring,
                                                                    	A 	 Display
additional output of the control value as 1 byte value on the
PWM.
●● Monitoring function for the actual temperature, valve
protection function.                                                                             B
Functions of the push-buttons:
Selection of 1- 4 operating modes each push-button. Move                                         C
setpoint.
Dimensions D
   13           26
                                                                    	B 	Bus connection
                                                                    	C 	Programming LED
                                                                    	D 	Programming button
Ref 	                        page     Ref 	                      page     Ref 	                      page     Ref 	                      page       Ref 	                      page
CCT1A000.........................58   MGU2.801.55..................137    MGU3.041.30....................45   MGU3.105.25....................86     MGU3.163.25S..................87
CCT1A000....................... 115   MGU2.801.57..................137    MGU3.043.18....................99   MGU3.105.25N.................87       MGU3.163.30....................32
CCT1A010.........................58   MGU2.802.18..................137    MGU3.045.12....................44   MGU3.105.30....................32     MGU3.163.30N.................33
CCT1A010....................... 115   MGU2.802.25..................137    MGU3.045.18....................98   MGU3.105.30N.................33       MGU3.163.30S..................33
CCT1A020.........................57   MGU2.802.55..................137    MGU3.045.25....................98   MGU3.105T.18..................86      MGU3.201.12....................32
CCT1A020....................... 114   MGU2.802.57..................137    MGU3.045.30....................44   MGU3.105T.18N................87       MGU3.201.12N.................33
CCT1A021.........................57   MGU2.803.18..................137    MGU3.046.18....................98   MGU3.105T.30N................33       MGU3.201.12S..................33
CCT1A021....................... 114   MGU2.803.25..................137    MGU3.046.30....................44   MGU3.106.12....................34     MGU3.201.18N.................87
CCT1A022.........................57   MGU2.803.55..................137    MGU3.047.03....................45   MGU3.106.12C.................34       MGU3.201.18S..................87
CCT1A022....................... 114   MGU2.803.57..................137    MGU3.047.03....................99   MGU3.106.12CN...............34        MGU3.201.25....................86
CCT1A023.........................57   MGU2.804.18..................137    MGU3.047.12....................45   MGU3.106.12L..................34      MGU3.201.25N.................87
CCT1A023....................... 114   MGU2.804.25..................137    MGU3.047.18....................99   MGU3.106.12LN...............34        MGU3.201.25S..................87
CCT1A030.........................58   MGU2.804.55..................137    MGU3.047.25....................99   MGU3.106.12N.................34       MGU3.201.30....................32
CCT1A030....................... 115   MGU2.804.57..................137    MGU3.047.30....................45   MGU3.106.18....................88     MGU3.201.30N.................33
CCT1A031.........................58   MGU2.806.18..................137    MGU3.048.18....................99   MGU3.106.18C.................88       MGU3.201.30S..................33
CCT1A031....................... 115   MGU2.806.25..................137    MGU3.048.30....................45   MGU3.106.18CN...............88        MGU3.201T.12N................33
CCT1A090.........................58   MGU2.806.55..................137    MGU3.057.03....................43   MGU3.106.18L..................88      MGU3.201T.18..................86
CCT1A090....................... 115   MGU2.806.57..................137    MGU3.057.03....................97   MGU3.106.18LN...............88        MGU3.201T.18N................87
ENN35303....................... 119   MGU3.020.18....................99   MGU3.057.03SL................43     MGU3.106.18N.................88       MGU3.201T.25..................86
ENN37303....................... 119   MGU3.020.25....................99   MGU3.057.03SL................97     MGU3.106.25....................88     MGU3.201T.30N................33
MGU0.570.12....................58     MGU3.021.12....................45   MGU3.057.06....................43   MGU3.106.25C.................88       MGU3.203.12....................32
MGU0.570.18.................. 115     MGU3.021.18....................99   MGU3.057.06....................97   MGU3.106.25CN...............88        MGU3.203.12N.................33
MGU0.570.25.................. 115     MGU3.021.25....................99   MGU3.057.12....................43   MGU3.106.25L..................88      MGU3.203.12S..................33
MGU0.570.30....................58     MGU3.021.30....................45   MGU3.057.12TA................43     MGU3.106.25LN...............88        MGU3.203.12VMC............36
MGU0.821.........................51   MGU3.023.12....................44   MGU3.057.18....................97   MGU3.106.25N.................88       MGU3.203.18....................86
MGU0.821.......................108    MGU3.023.18....................98   MGU3.057.18SL................97     MGU3.106.30....................34     MGU3.203.18N.................87
MGU0.822.AL....................35     MGU3.023.25....................98   MGU3.057.18TA................97     MGU3.106.30C.................34       MGU3.203.18S..................87
MGU0.822.AL....................89     MGU3.023.30....................44   MGU3.057.25....................97   MGU3.106.30CN...............34        MGU3.203.18VMC............90
MGU0.822.AZL..................35      MGU3.027.18..................100    MGU3.057.25TA................97     MGU3.106.30L..................34      MGU3.203.25....................86
MGU0.822.AZL..................89      MGU3.027.25..................100    MGU3.057.30....................43   MGU3.106.30LN...............34        MGU3.203.25N.................87
MGU0.823.AM...................35      MGU3.028.12....................46   MGU3.057.30SL................43     MGU3.106.30N.................34       MGU3.203.25S..................87
MGU0.823.AM...................89      MGU3.028.18..................100    MGU3.057.30TA................43     MGU3.106T.12..................34      MGU3.203.30....................32
MGU0.824.........................42   MGU3.028.30....................46   MGU3.059.03....................98   MGU3.106T.12N................34       MGU3.203.30N.................33
MGU0.824.........................96   MGU3.030.12....................44   MGU3.059.03SL................44     MGU3.106T.18..................88      MGU3.203.30S..................33
MGU0.825.AL....................35     MGU3.030.18....................98   MGU3.059.12....................44   MGU3.106T.18N................88       MGU3.203.30VMC............36
MGU0.825.AL....................89     MGU3.030.30....................44   MGU3.059.18....................98   MGU3.106T.25..................88      MGU3.203T.18..................86
MGU0.825.AZL..................35      MGU3.031.12....................45   MGU3.059.25....................98   MGU3.106T.25N................88       MGU3.203T.30..................32
MGU0.825.AZL..................89      MGU3.031.18....................99   MGU3.059.30....................44   MGU3.106T.30..................34      MGU3.205.12....................32
MGU0.839.12....................46     MGU3.031.25....................99   MGU3.061.12....................46   MGU3.106T.30N................34       MGU3.205.12N.................33
MGU0.839.18..................100      MGU3.031.30....................45   MGU3.061.18..................100    MGU3.107T.12..................36      MGU3.205.18....................86
MGU0.839.30....................46     MGU3.033.12....................45   MGU3.061.25..................100    MGU3.107T.18..................90      MGU3.205.18N.................87
MGU2.002.18..................152      MGU3.033.18....................99   MGU3.061.30....................46   MGU3.107T.25..................90      MGU3.205.25....................86
MGU2.002.18M...............152        MGU3.033.25....................99   MGU3.068.18....................99   MGU3.107T.30..................36      MGU3.205.25N.................87
MGU2.002.25..................152      MGU3.033.30....................45   MGU3.068.30....................45   MGU3.108T.12..................36      MGU3.205.30....................32
MGU2.002.25M...............152        MGU3.036.12....................43   MGU3.077.12....................45   MGU3.108T.18..................90      MGU3.205.30N.................33
MGU2.002.559................152       MGU3.036.18....................97   MGU3.077.18....................99   MGU3.108T.25..................90      MGU3.205T.30..................32
MGU2.002.858................152       MGU3.036.25....................97   MGU3.077.25....................99   MGU3.108T.30..................36      MGU3.206.12....................34
MGU2.002.859................152       MGU3.036.30....................43   MGU3.077.30....................45   MGU3.109T.12..................36      MGU3.206.12C.................34
MGU2.004.18..................152      MGU3.037.03....................43   MGU3.101.12....................32   MGU3.109T.18..................90      MGU3.206.12CN...............34
MGU2.004.25..................152      MGU3.037.03....................97   MGU3.101.12N.................33     MGU3.109T.25..................90      MGU3.206.12L..................34
MGU2.004.559................152       MGU3.037.03SL................43     MGU3.101.18....................86   MGU3.109T.30..................36      MGU3.206.12LN...............34
MGU2.004.858................152       MGU3.037.03SL................97     MGU3.101.18....................86   MGU3.127T.12..................36      MGU3.206.12N.................34
MGU2.004.859................152       MGU3.037.06....................43   MGU3.101.18N.................87     MGU3.127T.30..................36      MGU3.206.18....................88
MGU2.006.18..................152      MGU3.037.06....................97   MGU3.101.18S..................87    MGU3.136.12....................34     MGU3.206.18C.................88
MGU2.006.25..................152      MGU3.037.12....................43   MGU3.101.25....................86   MGU3.136.18....................88     MGU3.206.18CN...............88
MGU2.006.559................152       MGU3.037.12SL................43     MGU3.101.25N.................87     MGU3.136.25....................88     MGU3.206.18L..................88
MGU2.006.858................152       MGU3.037.12TA................43     MGU3.101.25S..................87    MGU3.136.30....................34     MGU3.206.18LN...............88
MGU2.006.859................152       MGU3.037.18....................97   MGU3.101.30....................32   MGU3.161.12....................32     MGU3.206.18N.................88
MGU2.008.18..................152      MGU3.037.18SL................97     MGU3.101.30N.................33     MGU3.161.12N.................33       MGU3.206.25....................88
MGU2.008.25..................152      MGU3.037.18TA................97     MGU3.101T.18..................86    MGU3.161.12S..................33      MGU3.206.25C.................88
MGU2.008.559................152       MGU3.037.25....................97   MGU3.101T.18N................87     MGU3.161.18....................86     MGU3.206.25CN...............88
MGU2.008.858................152       MGU3.037.25SL................97     MGU3.101T.30..................32    MGU3.161.18N.................87       MGU3.206.25L..................88
MGU2.008.859................152       MGU3.037.25TA................97     MGU3.101T.30N................33     MGU3.161.18S..................87      MGU3.206.25LN...............88
MGU2.010.18..................152      MGU3.037.30....................43   MGU3.103.12....................32   MGU3.161.25....................86     MGU3.206.25N.................88
MGU2.010.25..................152      MGU3.037.30SL................43     MGU3.103.12N.................33     MGU3.161.25N.................87       MGU3.206.30....................34
MGU2.502.18..................149      MGU3.037.30TA................43     MGU3.103.12S..................33    MGU3.161.25S..................87      MGU3.206.30C.................34
MGU2.702.16..................136      MGU3.037.61....................43   MGU3.103.18....................86   MGU3.161.30....................32     MGU3.206.30CN...............34
MGU2.702.17..................136      MGU3.037.61....................97   MGU3.103.18N.................87     MGU3.161.30N.................33       MGU3.206.30L..................34
MGU2.702.18..................136      MGU3.039.03....................44   MGU3.103.18S..................87    MGU3.161.30S..................33      MGU3.206.30LN...............34
MGU2.702.25..................136      MGU3.039.03....................98   MGU3.103.25....................86   MGU3.162.12....................32     MGU3.206.30N.................34
MGU2.704.16..................136      MGU3.039.03SL................44     MGU3.103.25N.................87     MGU3.162.12S..................33      MGU3.206T.18..................88
MGU2.704.17..................136      MGU3.039.03SL................98     MGU3.103.25S..................87    MGU3.162.18....................86     MGU3.206T.18N................88
MGU2.704.18..................136      MGU3.039.12....................44   MGU3.103.30....................32   MGU3.162.18S..................87      MGU3.206T.30N................34
MGU2.704.25..................136      MGU3.039.12SL................44     MGU3.103.30N.................33     MGU3.162.25....................86     MGU3.207.12....................36
MGU2.706.16..................136      MGU3.039.18....................98   MGU3.103.30S..................33    MGU3.162.25S..................87      MGU3.207.18....................90
MGU2.706.17..................136      MGU3.039.18SL................98     MGU3.103T.12N................33     MGU3.162.30S..................33      MGU3.207.25....................90
MGU2.706.18..................136      MGU3.039.25....................98   MGU3.103T.18..................86    MGU3.163.12....................32     MGU3.207.30....................36
MGU2.706.25..................136      MGU3.039.30....................44   MGU3.103T.18N................87     MGU3.163.12N.................33       MGU3.207T.18..................90
MGU2.708.16..................136      MGU3.039.30SL................44     MGU3.103T.25..................86    MGU3.163.12S..................33      MGU3.208.12....................36
MGU2.708.17..................136      MGU3.040.18....................97   MGU3.103T.30..................32    MGU3.163.18....................86     MGU3.208.18....................90
MGU2.708.18..................136      MGU3.040.25....................97   MGU3.105.12....................32   MGU3.163.18N.................87       MGU3.208.25....................90
MGU2.708.25..................136      MGU3.041.12....................45   MGU3.105.12N.................33     MGU3.163.18S..................87      MGU3.208.30....................36
MGU2.801.18..................137      MGU3.041.18....................99   MGU3.105.18....................86   MGU3.163.25....................86     MGU3.208T.18..................90
MGU2.801.25..................137      MGU3.041.25....................99   MGU3.105.18N.................87     MGU3.163.25N.................87       MGU3.211.12....................32
Ref 	                       page    Ref 	                       page    Ref 	                       page    Ref 	                       page      Ref 	                         page
MGU3.211.18....................86   MGU3.411.25..................104    MGU3.444.12....................47   MGU3.490.18..................108      MGU3.535.18....................95
MGU3.211.25....................86   MGU3.411.30....................47   MGU3.444.18..................104    MGU3.490.25..................108      MGU3.535.25....................95
MGU3.211.30....................32   MGU3.412.12....................47   MGU3.444.25..................104    MGU3.490.30....................51     MGU3.535.30....................41
MGU3.213.12....................32   MGU3.412.18..................104    MGU3.444.30....................47   MGU3.491.12....................51     MGU3.540.12....................42
MGU3.213.18....................86   MGU3.412.25..................104    MGU3.445.12....................47   MGU3.491.18..................108      MGU3.540.12CS...............42
MGU3.213.25....................86   MGU3.412.30....................47   MGU3.445.18..................104    MGU3.491.25..................108      MGU3.540.18....................96
MGU3.213.30....................32   MGU3.413.12....................47   MGU3.445.25..................104    MGU3.491.30....................51     MGU3.540.25....................96
MGU3.214.12....................36   MGU3.413.18..................104    MGU3.445.30....................47   MGU3.492.12....................51     MGU3.540.30....................42
MGU3.214.18....................90   MGU3.413.25..................104    MGU3.446.12....................47   MGU3.492.18..................108      MGU3.540.30CS...............42
MGU3.214.30....................36   MGU3.413.30....................47   MGU3.446.18..................104    MGU3.492.25..................108      MGU3.541.12....................41
MGU3.216.18CN...............89      MGU3.414.12....................47   MGU3.446.25..................104    MGU3.492.30....................51     MGU3.541.18....................95
MGU3.216.25CN...............89      MGU3.414.18..................104    MGU3.446.30....................47   MGU3.493.12....................51     MGU3.541.25....................95
MGU3.216.30CN...............35      MGU3.414.25..................104    MGU3.447.12....................47   MGU3.493.18..................108      MGU3.541.30....................41
MGU3.223.18....................91   MGU3.414.30....................47   MGU3.447.18..................104    MGU3.493.25..................108      MGU3.545.12....................42
MGU3.224.18....................91   MGU3.415.12....................47   MGU3.447.25..................104    MGU3.493.30....................51     MGU3.545.18....................96
MGU3.224.18S..................91    MGU3.415.18..................104    MGU3.447.30....................47   MGU3.495.12....................51     MGU3.545.25....................96
MGU3.224.25....................91   MGU3.415.25..................104    MGU3.450.12....................49   MGU3.495.18..................108      MGU3.545.30....................42
MGU3.224.25S..................91    MGU3.415.30....................47   MGU3.450.18..................106    MGU3.495.25..................108      MGU3.546.12....................42
MGU3.224.30....................37   MGU3.416.12....................47   MGU3.450.30....................49   MGU3.495.30....................51     MGU3.546.18....................96
MGU3.224.30S..................37    MGU3.416.18..................104    MGU3.451.12....................49   MGU3.497.12....................51     MGU3.546.25....................96
MGU3.226.12....................36   MGU3.416.25..................104    MGU3.451.18..................106    MGU3.497.18..................108      MGU3.546.30....................42
MGU3.226.18....................90   MGU3.416.30....................47   MGU3.451.25..................106    MGU3.497.25..................108      MGU3.559.12....................39
MGU3.226.25....................90   MGU3.417.12....................47   MGU3.451.30....................49   MGU3.497.30....................51     MGU3.559.18....................93
MGU3.226.30....................36   MGU3.417.18..................104    MGU3.452.12....................49   MGU3.498.12....................51     MGU3.559.25....................93
MGU3.231.12....................37   MGU3.417.25..................104    MGU3.452.18..................106    MGU3.498.18..................108      MGU3.559.30....................39
MGU3.231.18....................91   MGU3.417.30....................47   MGU3.452.25..................106    MGU3.498.25..................108      MGU3.572.12....................56
MGU3.231.25....................91   MGU3.418.12....................53   MGU3.452.30....................49   MGU3.498.30....................51     MGU3.572.18.................. 113
MGU3.231.30....................37   MGU3.418.18.................. 110   MGU3.453.12....................49   MGU3.499.12....................51     MGU3.572.25.................. 113
MGU3.232.12S..................37    MGU3.418.25.................. 110   MGU3.453.18..................106    MGU3.499.18..................108      MGU3.572.30....................56
MGU3.232.18S..................91    MGU3.418.30....................53   MGU3.453.25..................106    MGU3.499.25..................108      MGU3.573.12....................56
MGU3.232.25S..................91    MGU3.420.12....................47   MGU3.453.30....................49   MGU3.499.30....................51     MGU3.573.18.................. 113
MGU3.232.30S..................37    MGU3.420.18..................104    MGU3.454.12....................49   MGU3.501.12....................41     MGU3.573.25.................. 113
MGU3.236.12....................34   MGU3.420.25..................104    MGU3.454.18..................106    MGU3.501.18....................95     MGU3.573.30....................56
MGU3.236.18....................88   MGU3.420.30....................47   MGU3.454.25..................106    MGU3.501.25....................95     MGU3.574.12....................56
MGU3.236.25....................88   MGU3.421.18..................104    MGU3.454.30....................49   MGU3.501.30....................41     MGU3.574.18.................. 113
MGU3.236.30....................34   MGU3.421.25..................104    MGU3.455.12....................49   MGU3.503.12....................41     MGU3.574.25.................. 113
MGU3.246.1212V..............35      MGU3.422.12....................47   MGU3.455.18..................106    MGU3.503.18....................95     MGU3.574.30....................56
MGU3.246.1812V..............89      MGU3.422.18..................104    MGU3.455.25..................106    MGU3.503.25....................95     MGU3.579.12....................35
MGU3.246.2512V..............89      MGU3.422.25..................104    MGU3.455.30....................49   MGU3.503.30....................41     MGU3.579.18....................89
MGU3.246.3012V..............35      MGU3.422.30....................47   MGU3.456.12....................49   MGU3.505.12....................41     MGU3.579.25....................89
MGU3.261.12....................32   MGU3.423.12....................47   MGU3.456.18..................106    MGU3.505.18....................95     MGU3.579.30....................35
MGU3.261.12N.................33     MGU3.423.18..................104    MGU3.456.25..................106    MGU3.505.25....................95     MGU3.610.18....................92
MGU3.261.12S..................33    MGU3.423.25..................104    MGU3.456.30....................49   MGU3.505.30....................41     MGU3.610.25....................92
MGU3.261.18....................86   MGU3.423.30....................47   MGU3.462.12....................50   MGU3.510.12....................39     MGU3.611.18....................92
MGU3.261.18N.................87     MGU3.424.12....................47   MGU3.462.18..................107    MGU3.510.18....................93     MGU3.611.25....................92
MGU3.261.18S..................87    MGU3.424.18..................104    MGU3.462.25..................107    MGU3.510.25....................93     MGU3.612.18....................92
MGU3.261.25....................86   MGU3.424.25..................104    MGU3.462.30....................50   MGU3.510.30....................39     MGU3.612.25....................92
MGU3.261.25N.................87     MGU3.424.30....................47   MGU3.463.12....................50   MGU3.511.12....................39     MGU3.614.18....................92
MGU3.261.25S..................87    MGU3.425.12....................47   MGU3.463.18..................107    MGU3.511.18....................93     MGU3.614.25....................92
MGU3.261.30....................32   MGU3.425.18..................104    MGU3.463.25..................107    MGU3.511.25....................93     MGU3.615.18....................92
MGU3.261.30N.................33     MGU3.425.25..................104    MGU3.463.30....................50   MGU3.511.30....................39     MGU3.615.25....................92
MGU3.261.30S..................33    MGU3.425.30....................47   MGU3.464.12....................50   MGU3.515.12....................39     MGU3.630.18....................92
MGU3.262.12....................32   MGU3.426.12....................47   MGU3.464.18..................107    MGU3.515.18....................93     MGU3.630.25....................92
MGU3.262.12S..................33    MGU3.426.18..................104    MGU3.464.25..................107    MGU3.515.25....................93     MGU3.630.30....................38
MGU3.262.18....................86   MGU3.426.25..................104    MGU3.464.30....................50   MGU3.515.30....................39     MGU 3.631.12...................38
MGU3.262.18S..................87    MGU3.426.30....................47   MGU3.465.12....................50   MGU3.524.12....................40     MGU3.631.18....................92
MGU3.262.25....................86   MGU3.427.12....................47   MGU3.465.18..................107    MGU3.524.18....................94     MGU3.631.25....................92
MGU3.262.25S..................87    MGU3.427.18..................104    MGU3.465.25..................107    MGU3.524.25....................94     MGU3.631.30....................38
MGU3.262.30....................32   MGU3.427.25..................104    MGU3.465.30....................50   MGU3.524.30....................40     MGU3.632.18....................92
MGU3.262.30S..................33    MGU3.427.30....................47   MGU3.466.12....................50   MGU3.525.12....................40     MGU3.632.25....................92
MGU3.263.12....................32   MGU3.428.12....................53   MGU3.466.18..................107    MGU3.525.18....................94     MGU3.654.18....................92
MGU3.263.12N.................33     MGU3.428.18.................. 110   MGU3.466.25..................107    MGU3.525.25....................94     MGU3.654.25....................92
MGU3.263.12S..................33    MGU3.428.25.................. 110   MGU3.466.30....................50   MGU3.525.30....................40     MGU3.655.18....................92
MGU3.263.18....................86   MGU3.428.30....................53   MGU3.467.12....................50   MGU3.530.12....................59     MGU3.655.25....................92
MGU3.263.18N.................87     MGU3.429.12....................52   MGU3.467.18..................107    MGU3.530.18.................. 116     MGU3.656.18....................92
MGU3.263.18S..................87    MGU3.429.18..................109    MGU3.467.25..................107    MGU3.530.25.................. 116     MGU3.656.25....................92
MGU3.263.25....................86   MGU3.429.25..................109    MGU3.467.30....................50   MGU3.530.30....................59     MGU3.701.12....................35
MGU3.263.25N.................87     MGU3.429.30....................52   MGU3.468.12....................49   MGU3.531.12....................59     MGU3.701.18....................89
MGU3.263.25S..................87    MGU3.430.12....................52   MGU3.468.18..................106    MGU3.531.18.................. 116     MGU3.701.25....................89
MGU3.263.30....................32   MGU3.430.18..................109    MGU3.468.25..................106    MGU3.531.25.................. 116     MGU3.701.30....................35
MGU3.263.30N.................33     MGU3.430.25..................109    MGU3.468.30....................49   MGU3.531.30....................59     MGU3.710.12....................42
MGU3.263.30S..................33    MGU3.430.30....................52   MGU3.469.12....................49   MGU3.532.12....................59     MGU3.710.18....................96
MGU3.283.12....................42   MGU3.431.12....................52   MGU3.469.18..................106    MGU3.532.18.................. 116     MGU3.710.25....................96
MGU3.283.12CS...............42      MGU3.431.18..................109    MGU3.469.25..................106    MGU3.532.25.................. 116     MGU3.710.30....................42
MGU3.283.18....................96   MGU3.431.25..................109    MGU3.469.30....................49   MGU3.532.30....................59     MGU3.711.12....................42
MGU3.283.25....................96   MGU3.431.30....................52   MGU3.486.12....................53   MGU3.533.12....................60     MGU3.711.18....................96
MGU3.283.30....................42   MGU3.432.12....................52   MGU3.486.18.................. 110   MGU3.533.18.................. 117     MGU3.711.25....................96
MGU3.283.30CS...............42      MGU3.432.18..................109    MGU3.486.25.................. 110   MGU3.533.25.................. 117     MGU3.711.30....................42
MGU3.410.12....................47   MGU3.432.25..................109    MGU3.486.30....................53   MGU3.533.30....................60     MGU3.712.........................42
MGU3.410.18..................104    MGU3.432.30....................52   MGU3.487.12....................53   MGU3.534.12....................60     MGU3.712.........................96
MGU3.410.25..................104    MGU3.433.12....................52   MGU3.487.18.................. 110   MGU3.534.18.................. 117     MGU3.713.12....................42
MGU3.410.30....................47   MGU3.433.18..................109    MGU3.487.25.................. 110   MGU3.534.25.................. 117     MGU3.713.18....................96
MGU3.411.12....................47   MGU3.433.25..................109    MGU3.487.30....................53   MGU3.534.30....................60     MGU3.713.25....................96
MGU3.411.18..................104    MGU3.433.30....................52   MGU3.490.12....................51   MGU3.535.12....................41     MGU3.713.30....................42
Ref 	                       page     Ref 	                      page    Ref 	                      page     Ref 	                      page       Ref 	                      page
MGU3.716.12....................42    MGU4.102.13..................142   MGU5.064.18....................99   MGU6.004V.551..............125        MGU6.006V.577..............126
MGU3.716.18....................96    MGU4.102.18..................142   MGU5.064.30....................45   MGU6.004V.554..............125        MGU6.006V.824..............126
MGU3.716.25....................96    MGU4.102.24..................142   MGU5.512.12ZD...............39      MGU6.004V.563..............125        MGU6.006V.851..............126
MGU3.716.30....................42    MGU4.102.25..................142   MGU5.512.18ZD...............93      MGU6.004V.565..............125        MGU6.006V.854..............126
MGU3.775.12A..................51     MGU4.102.30..................142   MGU5.512.25ZD...............93      MGU6.004V.566..............125        MGU6.006V.865..............126
MGU3.775.12R.................51      MGU4.102.42..................142   MGU5.512.30ZD...............39      MGU6.004V.567..............125        MGU6.006V.867..............126
MGU3.775.12T..................51     MGU4.102.51..................142   MGU6.002.12....................76   MGU6.004V.569..............125        MGU6.006V.869..............126
MGU3.775.12V..................51     MGU4.102.54..................142   MGU6.002.18..................124    MGU6.004V.570..............125        MGU6.006V.870..............126
MGU3.775.18A................108      MGU4.102.58..................142   MGU6.002.25..................124    MGU6.004V.571..............125        MGU6.006V.871..............126
MGU3.775.18R...............108       MGU4.102.59..................142   MGU6.002.30....................76   MGU6.004V.572..............125        MGU6.006V.872..............126
MGU3.775.18T................108      MGU4.102.60..................142   MGU6.002.524................124     MGU6.004V.573..............125        MGU6.006V.873..............126
MGU3.775.18V................108      MGU4.102.62..................142   MGU6.002.542................124     MGU6.004V.574..............125        MGU6.006V.874..............126
MGU3.775.25A................108      MGU4.102.64..................142   MGU6.002.551................124     MGU6.004V.576..............125        MGU6.006V.876..............126
MGU3.775.25R...............108       MGU4.102.67..................142   MGU6.002.554................124     MGU6.004V.577..............125        MGU6.006V.877..............126
MGU3.775.25T................108      MGU4.103.13..................142   MGU6.002.563................124     MGU6.004V.824..............125        MGU6.008.12....................77
MGU3.775.25V................108      MGU4.103.18..................142   MGU6.002.565................124     MGU6.004V.842..............125        MGU6.008.18..................126
MGU3.775.30A..................51     MGU4.103.24..................142   MGU6.002.566................124     MGU6.004V.851..............125        MGU6.008.25..................126
MGU3.775.30R.................51      MGU4.103.25..................142   MGU6.002.567................124     MGU6.004V.854..............125        MGU6.008.30....................77
MGU3.775.30T..................51     MGU4.103.30..................142   MGU6.002.569................124     MGU6.004V.863..............125        MGU6.008.524................126
MGU3.775.30V..................51     MGU4.103.42..................142   MGU6.002.570................124     MGU6.004V.865..............125        MGU6.008.542................126
MGU3.776.T......................54   MGU4.103.51..................142   MGU6.002.571................124     MGU6.004V.866..............125        MGU6.008.551................126
MGU3.776.T.................... 111   MGU4.103.54..................142   MGU6.002.572................124     MGU6.004V.867..............125        MGU6.008.554................126
MGU3.780.T......................54   MGU4.103.58..................142   MGU6.002.573................124     MGU6.004V.869..............125        MGU6.008.563................126
MGU3.780.T.................... 111   MGU4.103.59..................142   MGU6.002.574................124     MGU6.004V.870..............125        MGU6.008.565................126
MGU3.785.12....................54    MGU4.103.60..................142   MGU6.002.576................124     MGU6.004V.871..............125        MGU6.008.566................126
MGU3.785.18.................. 111    MGU4.103.62..................142   MGU6.002.577................124     MGU6.004V.872..............125        MGU6.008.567................126
MGU3.785.25.................. 111    MGU4.103.64..................142   MGU6.002.824................124     MGU6.004V.873..............125        MGU6.008.569................126
MGU3.785.30....................54    MGU4.103.67..................142   MGU6.002.842................124     MGU6.004V.874..............125        MGU6.008.570................126
MGU3.786.12....................54    MGU4.104.13..................143   MGU6.002.851................124     MGU6.004V.876..............125        MGU6.008.571................126
MGU3.786.18.................. 111    MGU4.104.18..................143   MGU6.002.854................124     MGU6.004V.877..............125        MGU6.008.572................126
MGU3.786.25.................. 111    MGU4.104.24..................143   MGU6.002.863................124     MGU6.006.12....................77     MGU6.008.573................126
MGU3.786.30....................54    MGU4.104.25..................143   MGU6.002.865................124     MGU6.006.18..................125      MGU6.008.574................126
MGU3.860.12....................55    MGU4.104.30..................143   MGU6.002.866................124     MGU6.006.25..................125      MGU6.008.576................126
MGU3.860.18.................. 112    MGU4.104.42..................143   MGU6.002.867................124     MGU6.006.30....................77     MGU6.008.577................126
MGU3.860.25.................. 112    MGU4.104.51..................143   MGU6.002.869................124     MGU6.006.524................125       MGU6.008.824................126
MGU3.860.30....................55    MGU4.104.54..................143   MGU6.002.870................124     MGU6.006.542................125       MGU6.008.842................126
MGU3.862.12....................55    MGU4.104.58..................143   MGU6.002.871................124     MGU6.006.551................125       MGU6.008.851................126
MGU3.862.18.................. 112    MGU4.104.59..................143   MGU6.002.872................124     MGU6.006.554................125       MGU6.008.854................126
MGU3.862.25.................. 112    MGU4.104.60..................143   MGU6.002.873................124     MGU6.006.563................125       MGU6.008.863................126
MGU3.862.30....................55    MGU4.104.62..................143   MGU6.002.874................124     MGU6.006.565................125       MGU6.008.865................126
MGU4.000.01..................149     MGU4.104.64..................143   MGU6.002.876................124     MGU6.006.566................125       MGU6.008.866................126
MGU4.000.05..................149     MGU4.104.67..................143   MGU6.002.877................124     MGU6.006.567................125       MGU6.008.867................126
MGU4.000.06..................149     MGU4.106.13..................143   MGU6.004.12....................76   MGU6.006.569................125       MGU6.008.869................126
MGU4.000.13..................149     MGU4.106.18..................143   MGU6.004.18..................124    MGU6.006.570................125       MGU6.008.870................126
MGU4.000.18..................149     MGU4.106.24..................143   MGU6.004.25..................124    MGU6.006.571................125       MGU6.008.871................126
MGU4.000.24..................149     MGU4.106.25..................143   MGU6.004.30....................76   MGU6.006.572................125       MGU6.008.872................126
MGU4.000.25..................149     MGU4.106.30..................143   MGU6.004.524................124     MGU6.006.573................125       MGU6.008.873................126
MGU4.000.31..................149     MGU4.106.42..................143   MGU6.004.542................124     MGU6.006.574................125       MGU6.008.874................126
MGU4.000.34..................149     MGU4.106.51..................143   MGU6.004.551................124     MGU6.006.576................125       MGU6.008.876................126
MGU4.000.42..................149     MGU4.106.54..................143   MGU6.004.554................124     MGU6.006.577................125       MGU6.008.877................126
MGU4.000.43..................149     MGU4.106.58..................143   MGU6.004.563................124     MGU6.006.824................125       MGU6.014V.18................127
MGU4.000.44..................149     MGU4.106.59..................143   MGU6.004.565................124     MGU6.006.842................125       MGU6.014V.25................127
MGU4.000.48..................149     MGU4.106.60..................143   MGU6.004.566................124     MGU6.006.851................125       MGU6.014V.551..............127
MGU4.000.51..................149     MGU4.106.62..................143   MGU6.004.567................124     MGU6.006.854................125       MGU6.014V.567..............127
MGU4.000.54..................149     MGU4.106.64..................143   MGU6.004.569................124     MGU6.006.863................125       MGU6.014V.574..............127
MGU4.000.58..................149     MGU4.106.67..................143   MGU6.004.570................124     MGU6.006.865................125       MGU6.014V.824..............127
MGU4.000.59..................149     MGU4.702.26..................136   MGU6.004.571................124     MGU6.006.866................125       MGU6.014V.867..............127
MGU4.000.60..................149     MGU4.702.27..................136   MGU6.004.572................124     MGU6.006.867................125       MGU6.014V.871..............127
MGU4.000.62..................149     MGU4.702.28..................136   MGU6.004.573................124     MGU6.006.869................125       MGU6.014V.874..............127
MGU4.000.64..................149     MGU4.702.29..................136   MGU6.004.574................124     MGU6.006.870................125       MGU6.014V.877..............127
MGU4.002.18..................148     MGU4.702.35..................136   MGU6.004.576................124     MGU6.006.871................125       MGU6.016V.18................127
MGU4.002.25..................148     MGU4.702.36..................136   MGU6.004.577................124     MGU6.006.872................125       MGU6.016V.25................127
MGU4.004.18..................148     MGU4.702.37..................136   MGU6.004.824................124     MGU6.006.873................125       MGU6.016V.551..............127
MGU4.004.25..................148     MGU4.704.26..................136   MGU6.004.842................124     MGU6.006.874................125       MGU6.016V.567..............127
MGU4.006.18..................148     MGU4.704.27..................136   MGU6.004.851................124     MGU6.006.876................125       MGU6.016V.577..............127
MGU4.006.25..................148     MGU4.704.28..................136   MGU6.004.854................124     MGU6.006.877................125       MGU6.016V.824..............127
MGU4.008.18..................148     MGU4.704.29..................136   MGU6.004.863................124     MGU6.006V.12..................77      MGU6.016V.865..............127
MGU4.008.25..................148     MGU4.704.35..................136   MGU6.004.865................124     MGU6.006V.18................126       MGU6.016V.867..............127
MGU4.010.18..................148     MGU4.704.36..................136   MGU6.004.866................124     MGU6.006V.25................126       MGU6.016V.871..............127
MGU4.010.25..................148     MGU4.704.37..................136   MGU6.004.867................124     MGU6.006V.30..................77      MGU6.016V.874..............127
MGU4.101.13..................142     MGU4.706.26..................136   MGU6.004.869................124     MGU6.006V.524..............126        MGU6.016V.877..............127
MGU4.101.18..................142     MGU4.706.27..................136   MGU6.004.870................124     MGU6.006V.542..............126        MGU6.103.12....................79
MGU4.101.24..................142     MGU4.706.28..................136   MGU6.004.871................124     MGU6.006V.551..............126        MGU6.103.30....................79
MGU4.101.25..................142     MGU4.706.29..................136   MGU6.004.872................124     MGU6.006V.563..............126        MGU6.103.524................128
MGU4.101.30..................142     MGU4.706.35..................136   MGU6.004.873................124     MGU6.006V.565..............126        MGU6.103.542................128
MGU4.101.42..................142     MGU4.706.36..................136   MGU6.004.874................124     MGU6.006V.566..............126        MGU6.103.551................128
MGU4.101.51..................142     MGU4.706.37..................136   MGU6.004.876................124     MGU6.006V.567..............126        MGU6.103.554................128
MGU4.101.54..................142     MGU4.708.26..................136   MGU6.004.877................124     MGU6.006V.569..............126        MGU6.103.563................128
MGU4.101.58..................142     MGU4.708.27..................136   MGU6.004V.12..................76    MGU6.006V.570..............126        MGU6.103.565................128
MGU4.101.59..................142     MGU4.708.28..................136   MGU6.004V.18................125     MGU6.006V.571..............126        MGU6.103.566................128
MGU4.101.60..................142     MGU4.708.29..................136   MGU6.004V.25................125     MGU6.006V.572..............126        MGU6.103.567................128
MGU4.101.62..................142     MGU4.708.35..................136   MGU6.004V.30..................76    MGU6.006V.573..............126        MGU6.103.569................128
MGU4.101.64..................142     MGU4.708.36..................136   MGU6.004V.524..............125      MGU6.006V.574..............126        MGU6.103.570................128
MGU4.101.67..................142     MGU4.708.37..................136   MGU6.004V.542..............125      MGU6.006V.576..............126        MGU6.103.571................128
Ref 	                       page    Ref 	                         page    Ref 	                       page    Ref 	                      page     Ref 	                      page
MGU6.103.572................128     MGU6.506.25..................130      MGU9.200.12VMC............55        MGU23.063.18D.............101       MGU61.002.865..............130
MGU6.103.573................128     MGU6.702.55..................136      MGU9.200.18BOIL.......... 112       MGU23.063.25................101     MGU61.002.866..............130
MGU6.103.574................128     MGU6.702.56..................136      MGU9.200.18H............... 112     MGU23.063.25D.............101       MGU61.002.867..............130
MGU6.103.576................128     MGU6.702.57..................136      MGU9.200.18L................ 112    MGU23.065.18................101     MGU61.002.869..............130
MGU6.103.577................128     MGU6.704.55..................136      MGU9.200.18V................ 112    MGU23.065.18D.............101       MGU61.002.870..............130
MGU6.103.824................128     MGU6.704.56..................136      MGU9.200.18VMC.......... 112        MGU23.065.25................101     MGU61.002.871..............130
MGU6.103.842................128     MGU6.704.57..................136      MGU9.200.25BOIL.......... 112       MGU23.065.25D.............101       MGU61.002.872..............130
MGU6.103.851................128     MGU6.706.55..................136      MGU9.200.25H............... 112     MGU23.067.18................101     MGU61.002.873..............130
MGU6.103.854................128     MGU6.706.56..................136      MGU9.200.25L................ 112    MGU23.067.18D.............101       MGU61.002.874..............130
MGU6.103.863................128     MGU6.706.57..................136      MGU9.200.25V................ 112    MGU23.067.25................101     MGU61.002.876..............130
MGU6.103.866................128     MGU6.708.55..................136      MGU9.200.25VMC.......... 112        MGU23.067.25D.............101       MGU61.002.877..............130
MGU6.103.867................128     MGU6.708.56..................136      MGU9.200.30BOIL............55       MGU47.201.12P................81     MGU61.037.18..................97
MGU6.103.869................128     MGU6.708.57..................136      MGU9.200.30H.................55     MGU47.201.18P..............152      MGU61.037.25..................97
MGU6.103.870................128     MGU7.002.........................61   MGU9.200.30L..................55    MGU47.201.25P..............152      MGU63.063.18................102
MGU6.103.871................128     MGU7.002....................... 118   MGU9.200.30V..................55    MGU47.201.30P................81     MGU63.063.25................102
MGU6.103.872................128     MGU7.002.GG..................61       MGU9.200.30VMC............55        MGU47.202.12P................81     MGU63.063.524..............102
MGU6.103.873................128     MGU7.002.GG................ 118       MGU9.410.12....................47   MGU47.202.18P..............152      MGU63.063.563..............102
MGU6.103.874................128     MGU7.002.GL...................61      MGU9.410.18..................104    MGU47.202.25P..............152      MGU63.063.567..............102
MGU6.103.876................128     MGU7.002.GL................. 118      MGU9.410.25..................104    MGU47.202.30P................81     MGU63.063.824..............102
MGU6.103.877................128     MGU7.002.GLS.................61       MGU9.410.30....................47   MGU48.424.18................129     MGU63.063.842..............102
MGU6.104.12....................79   MGU7.002.GLS............... 118       MGU9.411.12....................47   MGU48.424.25................129     MGU63.063.851..............102
MGU6.104.30....................79   MGU7.002.P......................61    MGU9.411.18..................104    MGU48.424.524..............129      MGU63.063.854..............102
MGU6.104.524................128     MGU7.002.P.................... 118    MGU9.411.25..................104    MGU48.424.567..............129      MGU63.063.863..............102
MGU6.104.542................128     MGU7.002.PGL.................61       MGU9.411.30....................47   MGU48.424.571..............129      MGU63.063.865..............102
MGU6.104.551................128     MGU7.002.PGL............... 118       MGU9.420.12....................47   MGU48.424.574..............129      MGU63.063.866..............102
MGU6.104.563................128     MGU7.004.P......................61    MGU9.420.18..................104    MGU48.424.576..............129      MGU63.063.867..............102
MGU6.104.565................128     MGU7.004.P.................... 118    MGU9.420.25..................104    MGU48.424.824..............129      MGU63.063.869..............102
MGU6.104.566................128     MGU7.012.........................61   MGU9.420.30....................47   MGU48.424.842..............129      MGU63.063.870..............102
MGU6.104.567................128     MGU7.012....................... 118   MGU9.421.12....................47   MGU48.424.851..............129      MGU63.063.871..............102
MGU6.104.569................128     MGU7.012.GLS.................61       MGU9.421.18..................104    MGU48.424.854..............129      MGU63.063.872..............102
MGU6.104.571................128     MGU7.012.GLS............... 118       MGU9.421.25..................104    MGU48.424.863..............129      MGU63.063.874..............102
MGU6.104.572................128     MGU7.103.........................61   MGU9.421.30....................47   MGU48.424.865..............129      MGU63.063.876..............102
MGU6.104.573................128     MGU7.103....................... 118   MGU9.438.18..................105    MGU48.424.866..............129      MGU63.065.18................102
MGU6.104.574................128     MGU7.103.P......................61    MGU9.438.25..................105    MGU48.424.867..............129      MGU63.065.18D.............102
MGU6.104.576................128     MGU7.103.P.................... 118    MGU9.438.30....................48   MGU48.424.869..............129      MGU63.065.25................102
MGU6.104.577................128     MGU7.104.........................61   MGU9.439.18..................105    MGU48.424.871..............129      MGU63.065.25D.............102
MGU6.104.824................128     MGU7.104....................... 118   MGU9.440.12....................50   MGU48.424.872..............129      MGU63.065.524..............102
MGU6.104.842................128     MGU7.104.P......................61    MGU9.440.18..................107    MGU48.424.873..............129      MGU63.065.524D...........102
MGU6.104.851................128     MGU7.104.P.................... 118    MGU9.440.25..................107    MGU48.424.874..............129      MGU63.065.542D...........102
MGU6.104.854................128     MGU7.106....................... 118   MGU9.440.30....................50   MGU48.424.877..............129      MGU63.065.551..............102
MGU6.104.863................128     MGU7.892.........................61   MGU9.441.12....................50   MGU48.426.18................129     MGU63.065.551D...........102
MGU6.104.865................128     MGU7.892....................... 118   MGU9.441.18..................107    MGU48.426.25................129     MGU63.065.554..............102
MGU6.104.866................128     MGU7.892.A......................61    MGU9.441.25..................107    MGU48.426.524..............129      MGU63.065.554D...........102
MGU6.104.867................128     MGU7.892.A.................... 118    MGU9.441.30....................50   MGU48.426.567..............129      MGU63.065.563D...........102
MGU6.104.869................128     MGU8.002.18.................. 119     MGU9.460.12....................47   MGU48.426.574..............129      MGU63.065.565..............102
MGU6.104.871................128     MGU8.002.25.................. 119     MGU9.460.18..................104    MGU48.426.824..............129      MGU63.065.565D...........102
MGU6.104.872................128     MGU8.004.18.................. 119     MGU9.460.25..................104    MGU48.426.851..............129      MGU63.065.566D...........102
MGU6.104.873................128     MGU8.004.25.................. 119     MGU9.460.30....................47   MGU48.426.865..............129      MGU63.065.567..............102
MGU6.104.874................128     MGU8.006.18.................. 119     MGU9.461.12....................47   MGU48.426.867..............129      MGU63.065.567D...........102
MGU6.104.876................128     MGU8.006.25.................. 119     MGU9.461.18..................104    MGU48.426.871..............129      MGU63.065.569..............102
MGU6.104.877................128     MGU8.103.18.................. 119     MGU9.461.25..................104    MGU48.426.872..............129      MGU63.065.569D...........102
MGU6.106.12....................79   MGU8.103.25.................. 119     MGU9.461.30....................47   MGU48.426.874..............129      MGU63.065.571..............102
MGU6.106.30....................79   MGU8.104.18.................. 119     MGU9.864.12....................55   MGU48.426.877..............129      MGU63.065.571D...........102
MGU6.106.524................128     MGU8.104.25.................. 119     MGU9.864.18.................. 112   MGU49.424.010................80     MGU63.065.572..............102
MGU6.106.542................128     MGU8.601.........................61   MGU9.864.25.................. 112   MGU49.424.038................80     MGU63.065.572D...........102
MGU6.106.551................128     MGU8.601....................... 119   MGU9.864.30....................55   MGU49.424.039................80     MGU63.065.574..............102
MGU6.106.554................128     MGU8.603.........................61   MGU9.865.12....................55   MGU49.424.210................80     MGU63.065.574D...........102
MGU6.106.563................128     MGU8.603....................... 119   MGU9.865.18.................. 112   MGU49.424.238................80     MGU63.065.576D...........102
MGU6.106.565................128     MGU8.604.........................61   MGU9.865.25.................. 112   MGU49.424.239................80     MGU63.065.577..............102
MGU6.106.566................128     MGU8.604....................... 119   MGU9.865.30....................55   MGU49.424.504..............129      MGU63.065.577D...........102
MGU6.106.567................128     MGU8.624.........................61   MGU9.866.12....................55   MGU49.424.510..............129      MGU63.065.824..............102
MGU6.106.569................128     MGU8.624....................... 119   MGU9.866.18.................. 112   MGU49.424.804..............129      MGU63.065.824D...........102
MGU6.106.571................128     MGU8.626.........................61   MGU9.866.25.................. 112   MGU49.424.810..............129      MGU63.065.842D...........102
MGU6.106.572................128     MGU8.626....................... 119   MGU9.866.30....................55   MGU49.426.010................80     MGU63.065.851..............102
MGU6.106.574................128     MGU9.100.12BOIL............55         MGU9.868.18.................. 112   MGU49.426.038................80     MGU63.065.851D...........102
MGU6.106.576................128     MGU9.100.12H.................55       MGU9.868.25.................. 112   MGU49.426.039................80     MGU63.065.854..............102
MGU6.106.824................128     MGU9.100.12L..................55      MGU9.868.30....................55   MGU49.426.210................80     MGU63.065.854D...........102
MGU6.106.842................128     MGU9.100.12VMC............55          MGU11.103.18................130     MGU49.426.238................80     MGU63.065.863..............102
MGU6.106.851................128     MGU9.100.18BOIL.......... 112         MGU11.103.25................130     MGU49.426.239................80     MGU63.065.863D...........102
MGU6.106.854................128     MGU9.100.18H............... 112       MGU11.104.18................130     MGU49.426.504..............129      MGU63.065.865..............102
MGU6.106.863................128     MGU9.100.18L................ 112      MGU11.104.25................130     MGU49.426.510..............129      MGU63.065.865D...........102
MGU6.106.865................128     MGU9.100.18VMC.......... 112          MGU22.302.18................ 119    MGU49.426.804..............129      MGU63.065.866..............102
MGU6.106.866................128     MGU9.100.25BOIL.......... 112         MGU22.302.18................148     MGU49.426.810..............129      MGU63.065.866D...........102
MGU6.106.867................128     MGU9.100.25H............... 112       MGU22.302.18................153     MGU61.002.18................130     MGU63.065.867..............102
MGU6.106.869................128     MGU9.100.25L................ 112      MGU22.302.25................ 119    MGU61.002.18G.............130       MGU63.065.867D...........102
MGU6.106.870................128     MGU9.100.25VMC.......... 112          MGU22.302.25................148     MGU61.002.25................130     MGU63.065.869..............102
MGU6.106.871................128     MGU9.100.30BOIL............55         MGU22.302.25................153     MGU61.002.25G.............130       MGU63.065.869D...........102
MGU6.106.872................128     MGU9.100.30H.................55       MGU22.304.18................ 119    MGU61.002.804..............130      MGU63.065.870..............102
MGU6.106.874................128     MGU9.100.30L..................55      MGU22.304.18................148     MGU61.002.810..............130      MGU63.065.870D...........102
MGU6.106.876................128     MGU9.100.30VMC............55          MGU22.304.18................153     MGU61.002.824..............130      MGU63.065.871..............102
MGU6.106.877................128     MGU9.200.12BOIL............55         MGU22.304.25................ 119    MGU61.002.842..............130      MGU63.065.871D...........102
MGU6.502.18..................130    MGU9.200.12H.................55       MGU22.304.25................148     MGU61.002.851..............130      MGU63.065.872..............102
MGU6.502.25..................130    MGU9.200.12L..................55      MGU22.304.25................153     MGU61.002.854..............130      MGU63.065.872D...........102
MGU6.504.18..................130    MGU9.200.12V..................55      MGU23.063.18................101     MGU61.002.863..............130      MGU63.065.873D...........102
Ref 	                     page    Ref 	                    page     Ref 	                    page     Ref 	                    page       Ref 	                       page
MGU63.065.874..............102    MGU66.002.510..............124    MGU66.006.294................77   MGU66.014V.292..............78      MGU66.106.095................79
MGU63.065.874D...........102      MGU66.002.804..............124    MGU66.006.295................77   MGU66.014V.296..............78      MGU66.106.096................79
MGU63.065.876..............102    MGU66.002.810..............124    MGU66.006.296................77   MGU66.014V.297..............78      MGU66.106.097................79
MGU63.065.876D...........102      MGU66.004.0M2...............76    MGU66.006.297................77   MGU66.016V.0M2.............78       MGU66.106.098................79
MGU63.065.877..............102    MGU66.004.0M3...............76    MGU66.006.298................77   MGU66.016V.2M3.............78       MGU66.106.210................79
MGU63.065.877D...........102      MGU66.004.0M4...............76    MGU66.006.504..............125    MGU66.016V.2M4.............78       MGU66.106.238................79
MGU63.067.18................103   MGU66.004.2M2...............76    MGU66.006.510..............125    MGU66.016V.010..............78      MGU66.106.239................79
MGU63.067.18D.............103     MGU66.004.2M3...............76    MGU66.006.804..............125    MGU66.016V.038..............78      MGU66.106.292................79
MGU63.067.25................103   MGU66.004.2M4...............76    MGU66.006.810..............125    MGU66.016V.039..............78      MGU66.106.293................79
MGU63.067.25D.............103     MGU66.004.010................76   MGU66.006V.0M2.............77     MGU66.016V.092..............78      MGU66.106.294................79
MGU63.067.524..............103    MGU66.004.038................76   MGU66.006V.0M3.............77     MGU66.016V.096..............78      MGU66.106.295................79
MGU63.067.524D...........103      MGU66.004.039................76   MGU66.006V.0M4.............77     MGU66.016V.097..............78      MGU66.106.296................79
MGU63.067.551..............103    MGU66.004.092................76   MGU66.006V.2M2.............77     MGU66.016V.210..............78      MGU66.106.297................79
MGU63.067.554..............103    MGU66.004.093................76   MGU66.006V.2M3.............77     MGU66.016V.238..............78      MGU66.106.298................79
MGU63.067.567..............103    MGU66.004.094................76   MGU66.006V.2M4.............77     MGU66.016V.239..............78      MGU68.002.7A1................70
MGU63.067.571..............103    MGU66.004.095................76   MGU66.006V.010..............77    MGU66.016V.292..............78      MGU68.002.7A2................70
MGU63.067.572..............103    MGU66.004.096................76   MGU66.006V.038..............77    MGU66.016V.296..............78      MGU68.002.7A3................70
MGU63.067.576..............103    MGU66.004.097................76   MGU66.006V.039..............77    MGU66.016V.297..............78      MGU68.002.7C1...............70
MGU63.067.824..............103    MGU66.004.098................76   MGU66.006V.092..............77    MGU66.103.0M2...............79      MGU68.002.7C2...............70
MGU63.067.824D...........103      MGU66.004.210................76   MGU66.006V.093..............77    MGU66.103.0M3...............79      MGU68.002.7C3...............70
MGU63.067.842..............103    MGU66.004.238................76   MGU66.006V.094..............77    MGU66.103.0M4...............79      MGU68.002.7P1................70
MGU63.067.851..............103    MGU66.004.239................76   MGU66.006V.095..............77    MGU66.103.2M2...............79      MGU68.002.7P2................70
MGU63.067.854..............103    MGU66.004.292................76   MGU66.006V.096..............77    MGU66.103.2M3...............79      MGU68.002.7Z1................70
MGU63.067.863..............103    MGU66.004.293................76   MGU66.006V.097..............77    MGU66.103.2M4...............79      MGU68.004.7A1................70
MGU63.067.865D...........103      MGU66.004.294................76   MGU66.006V.098..............77    MGU66.103.010................79     MGU68.004.7A2................70
MGU63.067.866..............103    MGU66.004.295................76   MGU66.006V.210..............77    MGU66.103.038................79     MGU68.004.7A3................70
MGU63.067.867..............103    MGU66.004.296................76   MGU66.006V.238..............77    MGU66.103.039................79     MGU68.004.7C1...............70
MGU63.067.867D...........103      MGU66.004.297................76   MGU66.006V.239..............77    MGU66.103.092................79     MGU68.004.7C2...............70
MGU63.067.869..............103    MGU66.004.298................76   MGU66.006V.292..............77    MGU66.103.093................79     MGU68.004.7C3...............70
MGU63.067.870..............103    MGU66.004.504..............124    MGU66.006V.293..............77    MGU66.103.094................79     MGU68.004.7P1................70
MGU63.067.870D...........103      MGU66.004.510..............124    MGU66.006V.294..............77    MGU66.103.095................79     MGU68.004.7P2................70
MGU63.067.871..............103    MGU66.004.804..............124    MGU66.006V.295..............77    MGU66.103.096................79     MGU68.004.7Z1................70
MGU63.067.872..............103    MGU66.004.810..............124    MGU66.006V.296..............77    MGU66.103.097................79     MGU68.006.7A1................70
MGU63.067.872D...........103      MGU66.004V.0M2.............76     MGU66.006V.297..............77    MGU66.103.098................79     MGU68.006.7A2................70
MGU63.067.877..............103    MGU66.004V.0M3.............76     MGU66.006V.298..............77    MGU66.103.204................79     MGU68.006.7A3................70
MGU63.069.18................103   MGU66.004V.0M4.............76     MGU66.006V.504............126     MGU66.103.210................79     MGU68.006.7C1...............70
MGU63.069.25................103   MGU66.004V.2M2.............76     MGU66.006V.510............126     MGU66.103.238................79     MGU68.006.7C2...............70
MGU63.069.524..............103    MGU66.004V.2M3.............76     MGU66.006V.804............126     MGU66.103.239................79     MGU68.006.7C3...............70
MGU63.069.551..............103    MGU66.004V.2M4.............76     MGU66.006V.810............126     MGU66.103.292................79     MGU68.006.7P1................70
MGU63.069.567..............103    MGU66.004V.010..............76    MGU66.008.0M2...............77    MGU66.103.293................79     MGU68.006.7P2................70
MGU63.069.574..............103    MGU66.004V.038..............76    MGU66.008.0M3...............77    MGU66.103.294................79     MGU68.006.7Z1................70
MGU63.069.824..............103    MGU66.004V.039..............76    MGU66.008.0M4...............77    MGU66.103.295................79     MGU68.008.7A1................70
MGU63.069.842..............103    MGU66.004V.092..............76    MGU66.008.2M2...............77    MGU66.103.296................79     MGU68.008.7A2................70
MGU63.069.851..............103    MGU66.004V.093..............76    MGU66.008.2M3...............77    MGU66.103.297................79     MGU68.008.7A3................70
MGU63.069.854..............103    MGU66.004V.094..............76    MGU66.008.2M4...............77    MGU66.103.298................79     MGU68.008.7C1...............70
MGU63.069.863..............103    MGU66.004V.095..............76    MGU66.008.010................77   MGU66.103.804..............128      MGU68.008.7C2...............70
MGU63.069.865..............103    MGU66.004V.096..............76    MGU66.008.038................77   MGU66.103.810..............128      MGU68.008.7C3...............70
MGU63.069.866..............103    MGU66.004V.097..............76    MGU66.008.039................77   MGU66.104.0M2...............79      MGU68.008.7P1................70
MGU63.069.867..............103    MGU66.004V.098..............76    MGU66.008.092................77   MGU66.104.0M3...............79      MGU68.008.7P2................70
MGU63.069.869..............103    MGU66.004V.210..............76    MGU66.008.093................77   MGU66.104.0M4...............79      MGU68.008.7Z1................70
MGU63.069.870..............103    MGU66.004V.238..............76    MGU66.008.094................77   MGU66.104.2M2...............79      MGU70.566.12..................53
MGU63.069.871..............103    MGU66.004V.239..............76    MGU66.008.095................77   MGU66.104.2M3...............79      MGU70.566.18................ 110
MGU63.069.872..............103    MGU66.004V.292..............76    MGU66.008.096................77   MGU66.104.2M4...............79      MGU70.566.25................ 110
MGU63.069.873..............103    MGU66.004V.293..............76    MGU66.008.097................77   MGU66.104.010................79     MGU70.566.30..................53
MGU63.069.874..............103    MGU66.004V.294..............76    MGU66.008.098................77   MGU66.104.038................79     MGU70.567.12..................53
MGU63.069.876..............103    MGU66.004V.295..............76    MGU66.008.210................77   MGU66.104.039................79     MGU70.567.18................ 110
MGU63.069.877..............103    MGU66.004V.296..............76    MGU66.008.238................77   MGU66.104.092................79     MGU70.567.25................ 110
MGU66.002.0M2...............76    MGU66.004V.297..............76    MGU66.008.239................77   MGU66.104.093................79     MGU70.567.30..................53
MGU66.002.0M3...............76    MGU66.004V.298..............76    MGU66.008.292................77   MGU66.104.095................79     MGU70.598.......................53
MGU66.002.0M4...............76    MGU66.004V.504............125     MGU66.008.293................77   MGU66.104.096................79     MGU70.598..................... 110
MGU66.002.2M2...............76    MGU66.004V.510............125     MGU66.008.294................77   MGU66.104.097................79     MGU84.071.18................ 113
MGU66.002.2M3...............76    MGU66.004V.804............125     MGU66.008.295................77   MGU66.104.098................79     MGU84.071.25................ 113
MGU66.002.2M4...............76    MGU66.004V.810............125     MGU66.008.296................77   MGU66.104.210................79     MGU86.071.12..................56
MGU66.002.010................76   MGU66.006.0M2...............77    MGU66.008.297................77   MGU66.104.238................79     MGU86.071.18................ 113
MGU66.002.038................76   MGU66.006.0M3...............77    MGU66.008.298................77   MGU66.104.239................79     MGU86.071.25................ 113
MGU66.002.039................76   MGU66.006.0M4...............77    MGU66.008.504..............126    MGU66.104.292................79     MGU86.071.30..................56
MGU66.002.092................76   MGU66.006.2M2...............77    MGU66.008.510..............126    MGU66.104.293................79     MGU87.022.18................ 119
MGU66.002.093................76   MGU66.006.2M3...............77    MGU66.008.804..............126    MGU66.104.294................79     MGU87.022.25................ 119
MGU66.002.094................76   MGU66.006.2M4...............77    MGU66.008.810..............126    MGU66.104.295................79     MGU87.022.58..................61
MGU66.002.095................76   MGU66.006.010................77   MGU66.014V.0M2.............78     MGU66.104.296................79     MGU87.022.62..................61
MGU66.002.096................76   MGU66.006.038................77   MGU66.014V.0M3.............78     MGU66.104.297................79     MGU87.024.18................ 119
MGU66.002.097................76   MGU66.006.039................77   MGU66.014V.0M4.............78     MGU66.104.298................79     MGU87.024.25................ 119
MGU66.002.098................76   MGU66.006.092................77   MGU66.014V.2M2.............78     MGU66.106.0M2...............79      MGU87.024.58..................61
MGU66.002.210................76   MGU66.006.093................77   MGU66.014V.2M3.............78     MGU66.106.0M3...............79      MGU87.024.62..................61
MGU66.002.238................76   MGU66.006.094................77   MGU66.014V.2M4.............78     MGU66.106.0M4...............79      MGU87.026.18................ 119
MGU66.002.239................76   MGU66.006.095................77   MGU66.014V.010..............78    MGU66.106.2M2...............79      MGU87.026.25................ 119
MGU66.002.292................76   MGU66.006.096................77   MGU66.014V.038..............78    MGU66.106.2M3...............79      MGU87.026.58..................61
MGU66.002.293................76   MGU66.006.097................77   MGU66.014V.039..............78    MGU66.106.2M4...............79      MGU87.026.62..................61
MGU66.002.294................76   MGU66.006.098................77   MGU66.014V.092..............78    MGU66.106.010................79     MGU88.071.12..................56
MGU66.002.295................76   MGU66.006.210................77   MGU66.014V.096..............78    MGU66.106.038................79     MGU88.071.30..................56
MGU66.002.296................76   MGU66.006.238................77   MGU66.014V.097..............78    MGU66.106.039................79     MTN570222.......................59
MGU66.002.297................76   MGU66.006.239................77   MGU66.014V.210..............78    MGU66.106.092................79     MTN570222..................... 116
MGU66.002.298................76   MGU66.006.292................77   MGU66.014V.238..............78    MGU66.106.093................79
MGU66.002.504..............124    MGU66.006.293................77   MGU66.014V.239..............78    MGU66.106.094................79
Janvier, 2017
Unica catalogue